C7.1 Engines and Generator Sets Caterpillar


Exhaust System Contains Fuel

Usage:

C7.1 770

Probable Causes

  • Short circuit in the ARD fuel pump relay wiring

  • Corrosion in the wiring harness connectors for the ARD fuel pump relay

  • Failed ARD fuel pump relay

Recommended Actions



Illustration 1g06143030
ARD fuel pump schematic

Complete the procedure in the order in which the steps are listed.

Carefully following this procedure is a good way to identify wiring problems.

Table 1
Troubleshooting Test Steps  Values  Results 

1. Inspect the Components

A. Visually inspect the components for the ARD fuel pump system. Look for the following problems:

1. Loose connections or damaged connectors

2. Moisture on the connectors or the wiring

3. Damage that is caused by excessive heat

4. Damage that is caused by chafing

5. Improper routing of wiring

6. Damaged insulation
 

Damaged Wiring or Connectors 

Result: There is a problem with the wiring or a connector.

Repair: Repair the wiring or connector. Replace parts, if necessary.

Proceed to Test Step 4.

Result: The wiring is OK.

Proceed to Test Step 2.
 

2. Check for Voltage at the Coil for the ARD Fuel Pump Relay

A. Turn the keyswitch to the OFF position.

B. Measure voltage between the relay coil and a good ground source.

There should not be voltage on the relay coil when the keyswitch is in the OFF position. Low amounts of voltage can keep the relay pulled in after the keyswitch has been turned to the OFF position.
 

Voltage 

Result: There is voltage between the relay coil and a good ground source.

There may be a short from a power source in the wiring harness. There may be moisture or corrosion in a connector between the ECM and ARD fuel pump relay coil.

Make the necessary repairs.

Proceed to Test Step 4.

Result: There is not voltage between the relay coil and a good ground source.

Proceed to Test Step 3.
 

3. Check for Voltage at the Load Side of the ARD Fuel Pump Relay

A. Turn the keyswitch to the OFF position.

B. Measure voltage between the load side of the ARD fuel pump relay and a good ground source.
 

Voltage 

Result: There is voltage between the load side of the ARD fuel pump relay and a good ground source.

Remove the relay. Check for voltage between the load side of the ARD fuel pump relay and a good ground source.

If voltage is present, there is a short in the wiring between the relay and the ARD fuel pump. Repair or replace the wiring.

If voltage is not present, the relay has failed.

Repair: Replace the relay.

Proceed to Test Step 4.

Result: There is not voltage between the load side of the ARD fuel pump relay and a good ground source.

For further assistance, confer with the Dealer Solutions Network (DSN).
 

4. Clean Fuel from the Exhaust System

A. Remove excess fuel from the piping with a clean cloth.

B. Inhibit regeneration with the inhibit switch.

C. Operate the engine at elevated idle (1500 RPM) for 20 minutes.
 

Excess Fuel 

Result: The excess fuel and white smoke did not return after operating the engine for 20 minutes.

Repair: Perform a Manual DPF Regeneration using the electronic service tool.

Return the unit to service.

Result: The excess fuel and white smoke returned after operating the engine for 20 minutes.

Contact the Dealer Solutions Network (DSN).
 

Caterpillar Information System:

C7.1 Engines and Generator Sets Exhaust System Contains Coolant
C175 Oil&Gas Offshore Engine Solenoid Valve - Test - Engine
C175 Oil&Gas Offshore Engine Data Link - Test
C175 Oil&Gas Offshore Engine Engine Overspeeds
C175-16 and C175-20 Engines for Caterpillar Built Machines Engine Oil Filter Housing - Remove and Install
C175 Oil&Gas Offshore Engine Exhaust Temperature Is High
C175 Oil&Gas Offshore Engine Sensor Signal (Analog, Passive) - Test
An Installation Procedure for the TLV2 Seat Suspension Harness is Now Available {1408, 7324} An Installation Procedure for the TLV2 Seat Suspension Harness is Now Available {1408, 7324}
C7.1 Engines and Generator Sets Exhaust Has Excessive White Smoke
C7.1 Engines and Generator Sets Exhaust Has Excessive Black Smoke
C7.1 Engines and Generator Sets Engine Vibration Is Excessive
C7.1 Engines and Generator Sets Engine Top Speed Is Not Obtained
C175-16 Locomotive Engines Engine Electronics
C7.1 Engines and Generator Sets Exhaust System Contains Oil
C175-16 Locomotive Engines Product Lifting
C175-16 Locomotive Engines Configuration Parameters
C175-16 Locomotive Engines Starting the Engine
C7.1 Engines and Generator Sets Fuel Consumption Is Excessive
C7.1 Engines and Generator Sets Fuel Contains Water
C7.1 Engines and Generator Sets Fuel Rail Pressure Problem
C7.1 Engines and Generator Sets Fuel Temperature Is High
Photovoltaic Inverters Electrical Connections and Termination - Single Phase Inverters
C7.1 Engines and Generator Sets Inlet Air Is Restricted
C175-16 Locomotive Engines Overhaul (Intermediate)
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.