Winding Data for 109-3776 Generator through 109-7874 Generator
109-3776 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 304.8 mm (12.0 inch)     |
304.8 mm (12.0 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 10 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1364.0 mm (53.7 inch)     |
-     | |||||
Copper Weight     | 33.7 kg (74.4 lb)     |
48.3 kg (106.5 lb)     |
|||||
Inside Connection (1)     | 4/2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 10 - #000     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.00721 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.015 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 02 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3778 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 360.7 mm (14.2 inch)     |
360.7 mm (14.2 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 2.5     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 12 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1386.8 mm (54.6 inch)     |
-     | |||||
Copper Weight     | 36.8 kg (81.1 lb)     |
53.6 kg (118.2 lb)     |
|||||
Inside Connection (1)     | 4/2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 10 - #000     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0195 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.115 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 02 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3780 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 419.1 mm (16.5 inch)     |
419.1 mm (16.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 2.25 (2-2-2-3)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 10 - #14 and 5 - #15     | #8 SQ     | |||||
Mean Length Turn     | 1470.7 mm (57.9 inch)     |
-     | |||||
Copper Weight     | 41.7 kg (91.9 lb)     |
59.1 kg (130.4 lb)     |
|||||
Inside Connection (1)     | 4/2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 20 - #1     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.00459 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.225 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 01 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3782 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 495.3 mm (19.5 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 18 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1645.9 mm (64.8 inch)     |
-     | |||||
Copper Weight     | 52.9 kg (116.7 lb)     |
66.4 kg (146.4 lb)     |
|||||
Inside Connection (1)     | 4/2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 20 - #0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.014 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.40 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 01 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3784 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 254.0 mm (10.0 inch)     |
254.0 mm (10.0 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 3.5 (3-4-3-4)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 18 - #13     | #8 SQ     | |||||
Mean Length Turn     | 1165.9 mm (45.9 inch)     |
-     | |||||
Copper Weight     | 36.1 kg (79.5 lb)     |
43.5 kg (95.8 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 24 - #4     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.00827 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.909 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 1     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 7     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 03 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3786 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 276.9 mm (10.9 inch)     |
276.9 mm (10.9 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 3.25 (3-3-3-4)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 9 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1231.9 mm (48.5 inch)     |
-     | |||||
Copper Weight     | 31.4 kg (69.3 lb)     |
45.6 kg (100.6 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 24 - #4     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.00895 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.961 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 03 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3788 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 419.1 mm (16.5 inch)     |
419.1 mm (16.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 2.25 (2-2-2-3)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 10 - #14 and 5 - #15     | #8 SQ     | |||||
Mean Length Turn     | 1470.7 mm (57.9 inch)     |
-     | |||||
Copper Weight     | 41.7 kg (91.9 lb)     |
59.1 kg (130.4 lb)     |
|||||
Inside Connection (1)     | 4/2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 20 - #1     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.00459 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.225 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 01 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3790 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 495.3 mm (19.5 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 18 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1645.9 mm (64.8 inch)     |
-     | |||||
Copper Weight     | 52.9 kg (116.7 lb)     |
66.4 kg (146.4 lb)     |
|||||
Inside Connection (1)     | 4/2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 20 - #0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.014 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.40 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 01 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3792 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 198.1 mm (7.8 inch)     |
198.1 mm (7.8 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 9     | -     | |||||
Turns/Coil     | 6     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 7 - #15     | #8 SQ     | |||||
Mean Length Turn     | 972.8 mm (38.3 inch)     |
-     | |||||
Copper Weight     | 30.7 kg (67.7 lb)     |
38.1 kg (84.1 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #2     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0779 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.811 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 1     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 7     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
109-3794 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 223.5 mm (8.8 inch)     |
223.5 mm (8.8 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 5     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 7 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1079.5 mm (42.5 inch)     |
-     | |||||
Copper Weight     | 34.2 kg (75.5 lb)     |
40.6 kg (89.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #2     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0568 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.828 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 1     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 7     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
109-3796 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 254.0 mm (10.0 inch)     |
254.0 mm (10.0 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 4.5 (5-4-5-4)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 8 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1140.5 mm (44.9 inch)     |
-     | |||||
Copper Weight     | 37.2 kg (82.0 lb)     |
43.5 kg (95.8 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #1     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0470 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.909 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 1     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 7     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
109-3798 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 276.9 mm (10.9 inch)     |
276.9 mm (10.9 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 4.25 (5-4-4-4)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 8 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1234.4 mm (48.6 inch)     |
-     | |||||
Copper Weight     | 38.6 kg (85.0 lb)     |
45.6 kg (100.6 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0464 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.961 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
109-3800 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 419.1 mm (16.5 inch)     |
419.1 mm (16.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 12 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1470.7 mm (57.9 inch)     |
-     | |||||
Copper Weight     | 47.9 kg (105.7 lb)     |
59.1 kg (130.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #000     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0269 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.225 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
109-3802 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 495.3 mm (19.5 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 2.5 (3-2-3-2)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 14 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1645.9 mm (64.8 inch)     |
-     | |||||
Copper Weight     | 51.4 kg (113.4 lb)     |
66.4 kg (146.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #0000     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0215 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.40 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
109-3804 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 223.5 mm (8.8 inch)     |
223.5 mm (8.8 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 3.5 (3-4-3-4)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 10 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1079.5 mm (42.5 inch)     |
-     | |||||
Copper Weight     | 34.5 kg (76.0 lb)     |
40.6 kg (89.4 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 16 - #4     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.00736 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.828 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 1     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 7     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 09 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
109-3806 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 495.3 mm (19.5 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 8.54661     | -     | |||||
Turns/Coil     | 2-2-2-1     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 18 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1430.0 mm (56.3 inch)     |
-     | |||||
Copper Weight     | 50.1 kg (110.4 lb)     |
66.4 kg (146.4 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 16 - #00     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.00306 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 1.40 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 120 Hz     | ||||
Exciter Poles     | 6     | 8     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
31.8 mm (1.25 inch)     |
||||
Coils/Group     | 6     | 2     | 1     | ||||
Slots (Coils)     | 6     | 36     | 24     | ||||
Turns (Coils)     | 150     | 8     | 12     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | 2 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
330.2 mm (13.0 inch)     |
||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
0.5 kg (1.0 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | Star     | ||||
Line Leads     | 2 - #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 46 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
109-7874 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 292.10 mm (11.5 inch)     |
292.10 mm (11.5 inch)     |
|||||
Slots     | 60     | 4     | |||||
Coil Throw     | 1-12     | 1-2     | |||||
Turns/Coil     | 2.8 (3-3-2-3-3)     | -     | |||||
Turns/Pole     | -     | 110 (1)     | |||||
No. & Wire Size     | 10 # 14     | #7     | |||||
Mean Length Turn     | 1214.12 mm (47.8 inch)     |
990.6 mm (39 inch)     |
|||||
Copper Weight     | 39.4 kg (87 lb)     |
41.68 kg (91.9 lb)     |
|||||
Inside Connection     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 #2/0 (6 total)     | #8 (W23004-00)     | |||||
Low Voltage connected line resistance at 25° C (77.00000° F)     |
0.0312 ohms     | -     | |||||
Field lead resistance at 25° C (77.00000° F)     |
-     | 0.762 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | |||||
Exciter Poles     | 6     |     | |||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 101.6 mm (4 inch)     |
101.6 mm (4 inch)     |
    | ||||
Coils/Group     | 1     | 2     |     | ||||
Turns (Coils)     | 140     | 6     |     | ||||
No. & Size Wire     | 1 Of #15.5     | 2 of #15 GCU150     |     | ||||
Coil Throw     | 1 - 2     | 1 - 6     |     | ||||
Mean Length Turn     | 414.02 mm (16.3 inch)     |
355.6 mm (14 inch)     |
    | ||||
Resistance at 25° C (77.00000° F)     |
4.05     | 0.0746     |     | ||||
Copper Weight     | 4.67 kg (10.3 lb)     |
2.22 kg (4.9 lb)     |
    | ||||
Insulation     | Heavy Polyester Polyamide Imide     |     | |||||
Connection (2)     | Series     | Inter-connection to be #12 Ga. wire     |     | ||||
Line Leads     | 2 of #14 Ld     | 6 of #10 Ld     |     |
Show/hide table
( 1 ) | Wind 10 layers, 11 turns per layer for 110 turns total/pole. Layer wound 12.70 mm (0.5 inch) vent openings to divide layers 3-4-3 in coil heads. |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
Caterpillar Information System:
374F Excavator Hydraulic System General Information (Return System)
3500E EPA Tier 4 Final and IMO-II/III Switchable Marine Engines Sensor Calibration Required - Test
793F and 797F Off-Highway Trucks Braking System Automatic Retarder Control (ARC)
3512C Oil Well Service Engines Air Shutoff - Test
Installation of G610 Hardware for Cat® Terrain for Motor Graders, Wheel Dozers, and Wheel Loaders {7605} Installation of G610 Hardware for Cat® Terrain for Motor Graders, Wheel Dozers, and Wheel Loaders {7605}
2013/11/21 An Improved ARD Combustion Head is Now Used on Certain Tier 4 Engines {108B, 108E, 108M}
2013/11/11 An Improved ARD Combustion Head is Now Used on the Tier 4 Engines of Certain Machines {108B, 108E, 108M}
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 6I-0053 Generator through 6I-4860 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 203-5749 Generator through 324-5120 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 173-7078 Generator through 194-6563 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 164-0975 Generator through 164-4946 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 158-6410 Generator through 163-8546 Generator
2013/08/30 A New Adapter Is Used on Certain 3512C Petroleum Engines {1157}
966M Tier 4 and 972M Tier 4 Wheel Loaders Power Train Modulating Valve (Torque Converter Lockup Clutch) - Remove and Install
2014/10/10 Engine News Article List for <B>S/N:</B>8LL Engines {1000}
Improper Customer Access and Asset Merging Within VisionLinkTM and PartStoreTM Through UCID Consolidation{7567, 7606} Improper Customer Access and Asset Merging Within VisionLinkTM and PartStoreTM Through UCID Consolidation{7567, 7606}
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Control Manifold (Pilot Oil) - Disassemble
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Nozzle - Assemble
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Nozzle - Disassemble
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Water Cannon - Assemble
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Water Cannon - Disassemble
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Water Pump (Stainless Steel) - Assemble
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Water Pump (Stainless Steel) - Disassemble
CAT Water Delivery System (WDS) and 785D WTR OEM Off-Highway Truck/Tractor Water Pump (Stainless Steel) - Remove and Install