Winding Data for 6I-0053 Generator through 6I-4860 Generator
6I-0053 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 198.1 mm (7.8 inch)     |
198.1 mm (7.8 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 9     | -     | |||||
Turns/Coil     | 6     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 7 - #15     | #8 SQ     | |||||
Mean Length Turn     | 972.8 mm (38.3 inch)     |
-     | |||||
Copper Weight     | 30.7 kg (67.7 lb)     |
38.1 kg (84.1 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #2     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.0779 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.811 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 6     | 36     | -     | ||||
Turns (Coils)     | 150     | 7     | -     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
-     | ||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
6I-0055 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 223.5 mm (8.8 inch)     |
223.5 mm (8.8 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 3.5 (3-4-3-4)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 10 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1079.5 mm (42.5 inch)     |
-     | |||||
Copper Weight     | 34.5 kg (76.0 lb)     |
40.6 kg (89.4 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 16 - #4     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00736 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.828 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 6     | 36     | -     | ||||
Turns (Coils)     | 150     | 7     | -     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
-     | ||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 09 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
6I-0056 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 223.5 mm (8.8 inch)     |
223.5 mm (8.8 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 8 - #14 and 1 - #15     | #8 SQ     | |||||
Mean Length Turn     | 1079.5 mm (42.5 inch)     |
-     | |||||
Copper Weight     | 1927.9 mm (75.9 inch)     |
40.6 kg (89.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 24 - #4     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00982 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.828 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 6     | 36     | -     | ||||
Turns (Coils)     | 150     | 7     | -     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
-     | ||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 03 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram A |
6I-0059 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 223.5 mm (8.8 inch)     |
223.5 mm (8.8 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 5     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 7 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1079.5 mm (42.5 inch)     |
-     | |||||
Copper Weight     | 1917.7 mm (75.5 inch)     |
40.6 kg (89.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #2     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.0568 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.828 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 76.2 mm (3.0 inch)     |
76.2 mm (3.0 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 6     | 36     | -     | ||||
Turns (Coils)     | 150     | 7     | -     | ||||
No. & Size Wire     | 1 - #16     | 2 - #15.5     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 363.2 mm (14.3 inch)     |
325.1 mm (12.8 inch)     |
-     | ||||
Copper Weight     | 3.9 kg (8.5 lb)     |
2.2 kg (4.8 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
6I-0061 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 276.9 mm (10.9 inch)     |
276.9 mm (10.9 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 4.25 (5-4-4-4)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 8 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1234.4 mm (48.6 inch)     |
-     | |||||
Copper Weight     | 2159.0 mm (85.0 inch)     |
45.6 kg (100.6 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #0     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.0464 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.961 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 6     | 2     | -     | ||||
Slots (Coils)     | 6     | 36     | -     | ||||
Turns (Coils)     | 150     | 8     | -     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
-     | ||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
6I-0063 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 495.3 mm (19.5 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 2.5 (3-2-3-2)     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 14 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1645.9 mm (64.8 inch)     |
-     | |||||
Copper Weight     | 51.4 kg (113.4 lb)     |
66.4 kg (146.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 4 - #0000     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.0215 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.40 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 6     | 2     | -     | ||||
Slots (Coils)     | 6     | 36     | -     | ||||
Turns (Coils)     | 150     | 8     | -     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
-     | ||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 21 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
6I-0065 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 495.3 mm (19.5 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 48     | -     | |||||
Coil Throw     | 8.54661     | -     | |||||
Turns/Coil     | 2-2-2-1     | -     | |||||
Turns/Pole     | -     | 130     | |||||
No. & Wire Size     | 18 - #14     | #8 SQ     | |||||
Mean Length Turn     | 1430.0 mm (56.3 inch)     |
-     | |||||
Copper Weight     | 50.1 kg (110.4 lb)     |
66.4 kg (146.4 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 16 - #00     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00306 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.40 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 6     | 2     | -     | ||||
Slots (Coils)     | 6     | 36     | -     | ||||
Turns (Coils)     | 150     | 8     | -     | ||||
No. & Size Wire     | 1 - #16     | 2 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 388.6 mm (15.3 inch)     |
350.5 mm (13.8 inch)     |
-     | ||||
Copper Weight     | 4.1 kg (9.1 lb)     |
2.2 kg (4.8 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 46 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
6I-2676 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 685.8 mm (27.0 inch)     |
698.5 mm (27.5 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 216     | |||||
No. & Wire Size     | 2 - 3.3 mm (0.128 inch)× 4.8 mm (0.189 inch)     |
#6 SQ     | |||||
Mean Length Turn     | 2349.5 mm (92.5 inch)     |
-     | |||||
Copper Weight     | 153.6 kg (338.6 lb)     |
249.0 kg (549.0 lb)     |
|||||
Inside Connection (1)     | 1 Series Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 6 - #2     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.22 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.841 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-3088 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 596.9 mm (23.5 inch)     |
614.7 mm (24.2 inch)     |
|||||
Slots     | 84     | -     | |||||
Coil Throw     | 1 - 17     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 174     | |||||
No. & Wire Size     | 6 - 3.8 mm (0.148 inch)× 3.9 mm (0.153 inch)     |
3.7 mm (0.144 inch)× 7.3 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2400.3 mm (94.5 inch)     |
-     | |||||
Copper Weight     | 157.8 kg (348.0 lb)     |
298.9 kg (659.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 48 - #0     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00179 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.863 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram I |
6I-3090 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 660.4 mm (26.0 inch)     |
673.1 mm (26.5 inch)     |
|||||
Slots     | 84     | -     | |||||
Coil Throw     | 1 - 17     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 174     | |||||
No. & Wire Size     | 6 - 3.8 mm (0.148 inch)× 3.9 mm (0.153 inch)     |
3.7 mm (0.144 inch)× 7.3 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2608.6 mm (102.7 inch)     |
-     | |||||
Copper Weight     | 195.1 kg (430.1 lb)     |
320.1 kg (705.6 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 48 - #00     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00209 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.895 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram I |
6I-3092 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 520.7 mm (20.5 inch)     |
538.5 mm (21.2 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 174     | |||||
No. & Wire Size     | 4 - 3.4 mm (0.134 inch)× 6.1 mm (0.241 inch)     |
3.7 mm (0.144 inch)× 7.3 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2065.0 mm (81.3 inch)     |
-     | |||||
Copper Weight     | 187.0 kg (412.2 lb)     |
275.3 kg (607.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 48 - #1     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00272 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.765 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-3094 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 482.6 mm (19.0 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 13     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 216     | |||||
No. & Wire Size     | 4 - 3.1 mm (0.122 inch)× 4.2 mm (0.165 inch)     |
#6 SQ     | |||||
Mean Length Turn     | 1973.6 mm (77.7 inch)     |
-     | |||||
Copper Weight     | 126.9 kg (279.7 lb)     |
196.9 kg (434.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 24 - #0     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00477 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.476 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 19 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4827 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 762.0 mm (30.0 inch)     |
774.7 mm (30.5 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 14     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216     | |||||
No. & Wire Size     | 6 - #5 SQ     | 3.7 mm (0.144 inch)× 7.3 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2677.2 mm (105.4 inch)     |
-     | |||||
Copper Weight     | 216.7 kg (477.7 lb)     |
398.3 kg (878.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 48 - #00     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00137 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.15 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram I |
6I-4829 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 596.9 mm (23.5 inch)     |
614.7 mm (24.2 inch)     |
|||||
Slots     | 84     | -     | |||||
Coil Throw     | 1 - 18     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 174     | |||||
No. & Wire Size     | 40 - #14     | 3.7 mm (0.144 inch)× 7.3 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2402.8 mm (94.6 inch)     |
-     | |||||
Copper Weight     | 151.5 kg (334.0 lb)     |
298.9 kg (659.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 48 - #0     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00211 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.863 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram I |
6I-4833 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 477.5 mm (18.8 inch)     |
495.3 mm (19.5 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 174     | |||||
No. & Wire Size     | 31 - #14     | 3.7 mm (0.144 inch)× 7.3 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2001.5 mm (78.8 inch)     |
-     | |||||
Copper Weight     | 140.6 kg (310.0 lb)     |
259.9 kg (571.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 48 - #1     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.003255 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.716 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4835 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 762.0 mm (30.0 inch)     |
774.7 mm (30.5 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 16     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 195.5     | |||||
No. & Wire Size     | 4 - 3.0 mm (0.119 inch)× 4.3 mm (0.169 inch)     |
3.7 mm (0.144 inch)× 7.3 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2832.1 mm (111.5 inch)     |
-     | |||||
Copper Weight     | 186.0 kg (410.1 lb)     |
398.3 kg (878.0 lb)     |
|||||
Inside Connection (1)     | 1 Series Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 6 - #00     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.0972 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.15 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.3503 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 12 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram I |
6I-4839 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 685.8 mm (27.0 inch)     |
698.5 mm (27.5 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 216     | |||||
No. & Wire Size     | 6 - #7.5 SQ     | #6 SQ     | |||||
Mean Length Turn     | 2347.0 mm (92.4 inch)     |
-     | |||||
Copper Weight     | 177.2 kg (390.6 lb)     |
249.0 kg (549.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 48 - #2     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00339 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.841 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4841 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 685.8 mm (27.0 inch)     |
698.5 mm (27.5 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 14     | -     | |||||
Turns/Coil     | 1.5 (1-2-1-2-1-2)     | -     | |||||
Turns/Pole     | -     | 216     | |||||
No. & Wire Size     | 18 - #13     | #6 SQ     | |||||
Mean Length Turn     | 2303.8 mm (90.7 inch)     |
-     | |||||
Copper Weight     | 106.6 kg (235.0 lb)     |
249.0 kg (549.0 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     | 4 in Series     | |||||
Line Leads (No. & Size)     | 24 - #0000     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00437 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.841 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 120 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 63.5 mm (2.5 inch)     |
63.5 mm (2.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 7     | -     | ||||
No. & Size Wire     | 1 - #14     | 3 - #15     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 330.2 mm (13.0 inch)     |
386.1 mm (15.2 inch)     |
-     | ||||
Copper Weight     | 11.1 kg (24.5 lb)     |
6.2 kg (13.7 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 43 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4843 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 736.6 mm (29.0 inch)     |
749.3 mm (29.5 inch)     |
|||||
Slots     | 90     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 147.5     | |||||
No. & Wire Size     | 4 - #6 1/2     | 3.7 mm (0.144 inch)× 7.3152 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2382.5 mm (93.8 inch)     |
-     | |||||
Copper Weight     | 222.6 kg (490.7 lb)     |
69.9 kg (154.2 lb)     |
|||||
Inside Connection (1)     | 6 Parallel Star     | 6 in Series     | |||||
Line Leads (No. & Size)     | 36 - #0     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00271 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.161 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 80 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 06 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram I |
6I-4845 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 736.6 mm (29.0 inch)     |
749.3 mm (29.5 inch)     |
|||||
Slots     | 90     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 147.5     | |||||
No. & Wire Size     | 4 - 2.3 mm (0.089 inch)× 3.3 mm (0.131 inch)     |
3.7 mm (0.144 inch)× 7.3152 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2382.5 mm (93.8 inch)     |
-     | |||||
Copper Weight     | 168.0 kg (370.3 lb)     |
69.9 kg (154.2 lb)     |
|||||
Inside Connection (1)     | 1 Series Star     | 6 in Series     | |||||
Line Leads (No. & Size)     | 6 - #2     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.267 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.61 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 80 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 3 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 18 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram I |
6I-4847 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 487.7 mm (19.2 inch)     |
500.4 mm (19.7 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 9     | -     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 147.5     | |||||
No. & Wire Size     | 4 - 3.7 mm (0.145 inch)× 5.5 mm (0.215 inch)     |
3.7 mm (0.144 inch)× 7.3152 mm (0.288 inch)     |
|||||
Mean Length Turn     | 1788.2 mm (70.4 inch)     |
-     | |||||
Copper Weight     | 185.3 kg (408.6 lb)     |
49.1 kg (108.2 lb)     |
|||||
Inside Connection (1)     | 6 Parallel Star     | 6 in Series     | |||||
Line Leads (No. & Size)     | 36 - #1     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.004975 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.8655 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 80 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 06 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4849 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 487.7 mm (19.2 inch)     |
500.4 mm (19.7 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 5     | -     | |||||
Turns/Pole     | -     | 147.5     | |||||
No. & Wire Size     | 2 - 2.5 mm (0.100 inch)× 4.9 mm (0.194 inch)     |
3.7 mm (0.144 inch)× 7.3152 mm (0.288 inch)     |
|||||
Mean Length Turn     | 1955.8 mm (77.0 inch)     |
-     | |||||
Copper Weight     | 156.2 kg (344.3 lb)     |
49.1 kg (108.2 lb)     |
|||||
Inside Connection (1)     | 1 Series Star     | 6 in Series     | |||||
Line Leads (No. & Size)     | 6 - #2     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.351 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 0.8655 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 80 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 18 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4851 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 467.4 mm (18.4 inch)     |
480.1 mm (18.9 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 4     | -     | |||||
Turns/Pole     | -     | 154.5     | |||||
No. & Wire Size     | 2 - 3.7 mm (0.145 inch)× 4.8 mm (0.190 inch)     |
3.3 mm (0.130 inch)× 6.4 mm (0.250 inch)     |
|||||
Mean Length Turn     | 1882.1 mm (74.1 inch)     |
-     | |||||
Copper Weight     | 161.6 kg (356.2 lb)     |
36.7 kg (80.8 lb)     |
|||||
Inside Connection (1)     | 6 Parallel Star     | 6 in Series     | |||||
Line Leads (No. & Size)     | 36 - #2     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00558 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.12 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 80 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 06 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4853 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 419.1 mm (16.5 inch)     |
431.8 mm (17.0 inch)     |
|||||
Slots     | 72     | -     | |||||
Coil Throw     | 1 - 10     | -     | |||||
Turns/Coil     | 5     | -     | |||||
Turns/Pole     | -     | 154.5     | |||||
No. & Wire Size     | 2 - 2.8 mm (0.112 inch)× 4.8 mm (0.190 inch)     |
3.3 mm (0.130 inch)× 6.4 mm (0.250 inch)     |
|||||
Mean Length Turn     | 1706.9 mm (67.2 inch)     |
-     | |||||
Copper Weight     | 159.2 kg (351.0 lb)     |
34.2 kg (75.3 lb)     |
|||||
Inside Connection (1)     | 6 Parallel Star     | 6 in Series     | |||||
Line Leads (No. & Size)     | 36 - #4     | -     | |||||
Terminal bolt size     | 3/8 in     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00833 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.095 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 80 Hz     | Permanent Magnet Frequency     | - Hz     | ||||
Exciter Poles     | 8     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 88.9 mm (3.5 inch)     |
88.9 mm (3.5 inch)     |
-     | ||||
Coils/Group     | 1     | 2     | -     | ||||
Slots (Coils)     | 8     | 48     | -     | ||||
Turns (Coils)     | 160     | 8     | -     | ||||
No. & Size Wire     | 2 - #17 and 1 - #18     | 3 - #16     | -     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | -     | ||||
Mean Length Turn (Calc.)     | 355.6 mm (14.0 inch)     |
436.9 mm (17.2 inch)     |
-     | ||||
Copper Weight     | 14.0 kg (30.9 lb)     |
6.4 kg (14.0 lb)     |
-     | ||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel Star     | -     | ||||
Line Leads     | 2 - #14     | 6 - #10     | -     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 06 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram C |
6I-4856 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 914.4 mm (36 inch)     |
927.10 mm (36.5 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-9     | 1 - 2     | |||||
Turns/Coil     | 3     | -     | |||||
Turns/Pole     | -     | 163.5 (3)     | |||||
No. & Wire Size     | 2- 4.6228 mm (0.182 inch) x 4.6228 mm (0.182 inch)     |
3.6576 mm (0.144 inch) x 7.3152 mm (0.288 inch)     |
|||||
Mean Length Turn     | 2641.6 mm (104 inch)     |
2311.4 mm (91 inch)     |
|||||
Copper Weight     | 218.6 kg (482 lb)     |
549.7 kg (1212 lb)     |
|||||
Inside Connection (1)     | 1 Series Wye     | Series     | |||||
Line Leads (No. & Size)     | 6-1 of #1 6 total     | 2 of #6 Ld     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.17250 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.522 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 80 Hz     | 80 Hz     | 160 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 88.90 mm (3.5 inch)     |
88.90 mm (3.5 inch)     |
31.750 mm (1.25 inch)     |
||||
Coils/Group     | 1     | 1     | 1     | ||||
Turns (Coils)     | 160     | 16     | 17     | ||||
No. & Size Wire     | 1 of #18 GCU180 2 of #17 GCU170     | 3 of #16     | 2 of #17 GCU170     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4     | ||||
Mean Length Turn     | 355.6 mm (14 inch)     |
419.10 mm (16.5 inch)     |
2209.8 mm (87 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.2 ohms     | 0.122 ohms     | 0.509 ohms     | ||||
Copper Weight     | 14.01 kg (30.9 lb)     |
6.3 kg (14 lb)     |
0.566 kg (1.25 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 of #14 Ld     | 3 of #10 wire     | 3-1 of #14     |
Show/hide table
( 3 ) | Winding 4 layers - 15 turns, 2 layers - 14 turns, 1 layer - 13 turns, 1 layer - 12 turns, 1 layer - 11turns, 1 layer - 10 turns, 1 layer - 9 turns, 1 layer - 8 turns, 1 layer - 6.5 turns, 1 layer - 6 turns = 163.5 turns. |
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 06 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
6I-4860 Generator Ar
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 482.6 mm (19 inch)     |
495.30 mm (19.5 inch)     |
|||||
Slots     | 72     | 4     | |||||
Coil Throw     | 1-15     | 1 - 2     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 216     | |||||
No. & Wire Size     | 27 # 13     | #6 Square     | |||||
Mean Length Turn     | 1963.42 mm (77.3 inch)     |
1534.16 mm (60.4 inch)     |
|||||
Copper Weight     | 90.7 kg (200 lb)     |
196.8 kg (434 lb)     |
|||||
Inside Connection (1)     | 4 Parallel Star     |     | |||||
Line Leads (No. & Size)     | 12-4 #2/0 (48 total)     | 2 of #6 Ld     | |||||
Low Voltage connected line resistance at 25° C (77.0° F)     |
0.00172 ohms     | -     | |||||
Field lead resistance at 25° C (77.0° F)     |
-     | 1.476 ohms     | |||||
EXCITER WINDING DATA     | |||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Exciter Frequency (Hz)     | 80 Hz     | 80 Hz     | 240 Hz     | ||||
Exciter Poles     | 8     | 8     | 16     | ||||
Stack Length     | 63.50 mm (2.5 inch)     |
63.50 mm (2.5 inch)     |
25.4 mm (1 inch)     |
||||
Coils/Group     | 1     | 2     | 1     | ||||
Turns (Coils)     | 160     | 7     | 12     | ||||
No. & Size Wire     | 1 of #14 GCU140     | 3 of #15 GCU150     | 4 - # 18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1-4 29-35Lds     | ||||
Mean Length Turn     | 330.2 mm (13 inch)     |
368.30 mm (14.5 inch)     |
208.28 mm (8.2 inch)     |
||||
Resistance at 25° C (77.0° F)     |
3.82 ohms     | 0.0808 ohms     | 0.239 ohms     | ||||
Copper Weight     | 11.11 kg (24.5 lb)     |
6.21 kg (13.7 lb)     |
1.791 kg (3.95 lb)     |
||||
Connection (2)     | Series     | 2 Parallel Wye     | Wye     | ||||
Line Leads     | 2 of #14 Ld     | 6 of #10 Ld     | 3-1 OF #14 (3 total)     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 06 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
Caterpillar Information System:
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 203-5749 Generator through 324-5120 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 173-7078 Generator through 194-6563 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 164-0975 Generator through 164-4946 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 158-6410 Generator through 163-8546 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 149-2447 Generator through 150-9152 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 144-1964 Generator through 144-2088 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 136-6610 Generator through 136-6641 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 144-1666 Generator through 144-1766 Generator
3512C Petroleum Engines with Dynamic Gas Blending Engine Shutdown Occurrence
312D2 and 313D2 Excavators System Pressure Release
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 141-5534 Generator through 142-9900 Generator
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 136-6580 Generator through 136-6609 Generator
2013/11/11 An Improved ARD Combustion Head is Now Used on the Tier 4 Engines of Certain Machines {108B, 108E, 108M}
2013/11/21 An Improved ARD Combustion Head is Now Used on Certain Tier 4 Engines {108B, 108E, 108M}
Installation of G610 Hardware for Cat® Terrain for Motor Graders, Wheel Dozers, and Wheel Loaders {7605} Installation of G610 Hardware for Cat® Terrain for Motor Graders, Wheel Dozers, and Wheel Loaders {7605}
3512C Oil Well Service Engines Air Shutoff - Test
793F and 797F Off-Highway Trucks Braking System Automatic Retarder Control (ARC)
3500E EPA Tier 4 Final and IMO-II/III Switchable Marine Engines Sensor Calibration Required - Test
374F Excavator Hydraulic System General Information (Return System)
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 109-3776 Generator through 109-7874 Generator
2013/08/30 A New Adapter Is Used on Certain 3512C Petroleum Engines {1157}
966M Tier 4 and 972M Tier 4 Wheel Loaders Power Train Modulating Valve (Torque Converter Lockup Clutch) - Remove and Install
2014/10/10 Engine News Article List for <B>S/N:</B>8LL Engines {1000}
Improper Customer Access and Asset Merging Within VisionLinkTM and PartStoreTM Through UCID Consolidation{7567, 7606} Improper Customer Access and Asset Merging Within VisionLinkTM and PartStoreTM Through UCID Consolidation{7567, 7606}