Illustration 1 | g01350923 |
Right Side View |
Illustration 2 | g01359083 |
Section A-A Oil filter bypass |
(Section A-A) Oil filter bypass valve specifications
Nominal opening pressure of the oil filter bypass valve ...
Nominal closing pressure of the oil filter bypass valve ...
Maximum difference in pressure across a dirty filter from the inlet of the standard filter to the outlet of the oil filter. ...
Note: The specification includes a remote filter if installed.
Maximum difference in pressure across a new filter from the inlet of the standard filter to the outlet of the oil filter. ...
Note: The specification includes a remote filter if installed.
Illustration 3 | g01350925 |
Section B-B Oil cooler bypass |
(1) Torque for the plugs ...
(2) 4N-8150 Spring
- Assembled length ...
55.24 mm (2.17480 inch) - Load at assembled length ...
75.619 ± 5.8 N (17 ± 1.3 lb) - Free length after test ...
93.726 mm (3.69 inch) - Outside diameter ...
20.6 mm (0.81 inch) - Load at assembled length ...
Illustration 4 | g01350927 |
Section C-C Pump bypass valve |
(3) 2N-6005 Spring
- Assembled length ...
96.52 mm (3.800 inch) - Load at assembled length ...
92.52 N (21 lb) - Free length after test ...
124.71 mm (4.910 inch) - Outside diameter ...
21.84 mm (0.860 inch) - Load at assembled length ...
Illustration 5 | g01350929 |
Section D-D High-pressure relief valve |
(4) 1A-2170 Retainer Spring
- Assembled length ...
21.4 mm (0.8 inch) - Load at assembled length ...
200 ± 15.5 N (45.0 ± 3.5 lb) - Free length after test ...
31 mm (1.2 inch) - Outside diameter ...
19.66 ± 0.2 mm (0.77 ± 0.01 inch) - Load at assembled length ...