320E, 320F, 323E, 323F, 324E, 326F, 329E, 329F and 330F Excavators Tool Control System Caterpillar


Solenoid Valve (Proportional Reducing) - Calibrate - Flow Limit Valves

Usage:

320E AWS

Introduction

Negative flow control pressure flows to the regulators at the drive pump and the idler pump in order to control the output flow of the pumps. The proportional reducing valve for negative flow control regulates the amount of pilot pressure from the pilot pump and signal oil pressure from the main control valve that flows into the regulators of the main pumps. The proportional reducing valves for negative flow control are controlled by the machine ECM.

Required Tools



Illustration 1g01623868
Tooling (B)
198-4240 Digital Pressure Indicator Gp


Illustration 2g02280223
Tooling (D) (Flow meter tool layout)

Table 1
Required Tools 
Tool  Item  Part
Number 
Description  Qty 
198-4240  Digital Pressure Indicator Gp   
  B1  198-4234  Indicator 
B2 198-4239  Pressure Sensor
41,368 kPa (6,000 psi) 
B3 198-4236  Extension Cable 
D1  4C-9910  Portable hydraulic tester (flow meter) 
D2 6K-6307  O-Ring Seal 
D3 8C-9026  Adapter 
D4 7M-8485  O-Ring Seal 
D5 4C-6482  Fitting 
D6 4C-6481  Coupler 
D7 4C-8767  Coupling 
D8 5P-1010  Sleeve 
D9 5P-0201  Hose 
D10 1U-8293  Adapter 

Machine Preparation


NOTICE

Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the product. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids.

Refer to Special Publication, NENG2500, "Dealer Service Tool Catalog" for tools and supplies suitable to collect and contain fluids on Cat® products.

Dispose of all fluids according to local regulations and mandates.


  1. The following procedures must be completed before performing the calibration.

    • Set the pilot pressure to the specifications in Testing and Adjusting, "Relief Valve (Pilot) - Test and Adjust" for the machine.

    • Calibrate the power shift pressure. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Power Shift Pressure)" for the machine.

    • Calibrate the attachment valves. Refer to Testing and Adjusting, "Solenoid Valve (Proportional Reducing) - Calibrate (Attachment Valves)" for the Tool Control System.

  2. Position the machine on level ground.

  3. Stop the engine.


    Illustration 3g03602396
    Stop valves for high-pressure oil delivery to the work tool (typical example)

  4. Close the stop valves that are mounted on each side of the stick in order to prevent oil loss.

  5. Release pressure in the hydraulic system. Refer to Testing and Adjusting, "System Pressure - Release".


    Illustration 4g02280273
    Flow meter tool layout (stop valves on stick)
    (1) Left stop valve
    (2) Right stop valve

  6. Install the following tools in accordance with the flow meter tool layout. Refer to Illustration 4.

  7. Open the stop valves that are mounted on each side of the stick.


    Illustration 5g06267047
    Pump compartment (typical example)
    (3) Pressure tap (delivery pressure for drive pump)
    (4) Pressure tap (delivery pressure for idler pump)


    Illustration 6g06267048
    Pump compartment (typical example)
    (3) Pressure tap (delivery pressure for drive pump)
    (4) Pressure tap (delivery pressure for idler pump)

  8. Attach 41,368 kPa (6,000 psi) pressure sensors to pressure taps (3) and (4) for delivery pressure of the main pumps.

  9. Start the engine.

  10. Place the machine controls at the following settings: engine speed dial "10" and AEC switch OFF. Refer to Testing and Adjusting, "Engine Performance - Test (Engine Speed)" for engine rpm settings.

  11. Increase the hydraulic oil temperature to 50° ± 10°C (122° ± 18°F).

Calibration Procedure

------ WARNING! ------

To prevent personal injury or equipment damage from failure of the hydraulic test equipment or associated circuit components because of blocked pump flow, make sure that the test equipment valves are fully open before starting the engine.


------ WARNING! ------

To prevent personal injury and/or equipment damage from failed lines or components while the hydraulic test equipment is returned to the open flow position, slowly open the hydraulic test equipment valve while monitoring the pump flow.

If pump flow does not increase as the valve is opened, shut the engine off and determine what is preventing the pump from upstroking.


Note: This procedure is typical for both proportional reducing valves for pump flow limit.

Use any of the following control inputs (A) shown in Illustration 7 and 8 to calibrate the flow limit valves.



Illustration 7g02333296
Electric Control Inputs for extension of the attachment control valves
(LJ) Left-hand joystick
(RJ) Right-hand joystick
(A) Thumb wheel (Forward)
(A) Switch
(EP) Electric foot pedal
(A) Pedal (Forward)
(FS) Foot switch
(A) Foot switch (ON)


Illustration 8g03082697
Hydraulic Control Inputs for extension of the attachment control valves
(HP) Hydraulic foot pedal
(A) Pedal (Forward)

  1. Select a work tool that will allow for two-way flow from two pumps. The Variable Relief Valve #1 (Parameter #9) pressure setting must be set to 40000 kPa (5802 psi) for the work tool within the monitor.

    Reference: Refer to Testing and Adjusting, "Work Tool - Select" for the Tool Control System.

    Reference: Refer to Testing and Adjusting, "Work Tool Parameter - Program" for the Tool Control System.

Monitor Procedure

The following procedure will allow the user to calibrate the flow limit valves using the monitor.

  1. Enter the service mode. Input the password "9992".


    Illustration 9g02276293

  2. Select "Main Pump Flow Limit" from the "Calibrations" menu.


    Illustration 10g02280293

  3. Select "NFC (Flow Meter Method)" for the appropriate valve from the "Main Pump Flow Limit" menu.

  4. Press the OK key in order to start the calibration. The engine RPM will automatically increase to the equivalence of engine speed dial 10.

  5. Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.


    Illustration 11g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve


    Illustration 12g02611357

    Note: Refer to Illustration 7 for the control input.

  6. Press and hold the control input for activation of the work tool to the FULL ON position during calibration.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".

  7. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  8. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 120 ± 2 L/min (31.7 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  9. Repeat Steps 7 and 8 until the flow meter reads 120 ± 2 L/min (31.7 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  10. Press the OK key.


    Illustration 13g02611339

    Note: Refer to Illustration 7 for the control input.

  11. Press and hold the control input for activation of the work tool to the FULL ON position during calibration.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump #1 Outlet Pressure", and "Pump #2 Outlet Pressure".

  12. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  13. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 180 ± 2 L/min (47.6 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  14. Repeat Steps 12 and 13 until the flow meter reads 180 ± 2 L/min (47.6 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  15. Press the OK key.


    Illustration 14g02281293

  16. If calibration was successful and no errors occurred, the display will indicate that the calibration is complete.


    Illustration 15g02281435

  17. The "Error" screen will be displayed on the monitor if an error occurs. The process of calibration will not be saved and the process must be restarted.

Test Procedure

Confirm the calibration using the following procedure and specifications. Refer to Table 2 for the load pressure and flow specifications.

    Note: This procedure is typical for both proportional reducing valves for pump flow limit.

  1. Enter the service mode.


    Illustration 16g02283177

  2. Select "Main Pump Flow Limit" from the "Device Test" menu.


    Illustration 17g02283214

  3. Select the test for the appropriate valve from the "Main Pump Flow Limit" menu.

  4. Press the OK key in order to start the test.

  5. Confirm the notes on the monitor display. Set up the test conditions in accordance with the instructions. Press the OK key.


    Illustration 18g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve


    Illustration 19g02283194

  6. Set the main pump pressure using load valve (5) on the flow meter. Use the arrows to adjust the flow. Refer to Table 2 for the load pressures and flow specifications.

    Note: Use the arrows to scroll down to view the machine "Engine Speed", "Hydraulic Oil Temperature", "Pump Outlet Pressures", and "Pump NFC Pressures".

Table 2
"Solenoid Valve (Proportional Reducing) - Calibrate (Flow Limit Valves)" 
Machine Settings  Engine Speed 
Engine speed dial "10"
AEC switch OFF
Flow set using Device Test in Service Mode  Load pressure applied with flow meter 
12000 kPa (1740 psi) 16000 kPa (2321 psi) 20000 kPa (2901 psi) 
Flow Specifications
One Pump Flow  120 L/min (31.7 US gpm)  114 to 126 L/min (30.1 to 33.3 US gpm)  114 to 126 L/min (30.1 to 33.3 US gpm)  114 to 126 L/min (30.1 to 33.3 US gpm) 
160 L/min (42.3 US gpm) 152 to 168 L/min (40.1 to 44.4 US gpm)  152 to 168 L/min (40.1 to 44.4 US gpm)  152 to 168 L/min (40.1 to 44.4 US gpm) 
190 L/min (50.2 US gpm) 180 to 200 L/min (47.6 to 52.8 US gpm)  180 to 200 L/min (47.6 to 52.8 US gpm)  180 to 200 L/min (47.6 to 52.8 US gpm) 
Two Pump Flow  180 L/min (47.6 US gpm)  171 to 189 L/min (45.2 to 49.9 US gpm)  171 to 189 L/min (45.2 to 49.9 US gpm)  171 to 189 L/min (45.2 to 49.9 US gpm) 
200 L/min (52.8 US gpm) 190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm) 
220 L/min (58.1 US gpm) 209 to 231 L/min (55.2 to 61.0 US gpm)  209 to 231 L/min (55.2 to 61.0 US gpm)  209 to 231 L/min (55.2 to 61.0 US gpm) 

Cat Electronic Technician Procedure

The following procedure will allow the user to calibrate the flow limit valves using the Cat Electronic Technician.



    Illustration 20g02713701
    Diagnostic connector for Cat Electronic Technician

  1. Connect the Cat Electronic Technician to the diagnostic connector located behind the seat on the left side of the cab.


    Illustration 21g02713758

  2. Start Cat Electronic Technician.


    Illustration 22g02713761

  3. Select the ECM for "Machine Control".


    Illustration 23g02723808

  4. Select "Calibrations" from the "Service" menu.


    Illustration 24g02724846

  5. Highlight "PRV - Main Pump Flow Limitation Pressure Calibration" and click on the "Start" button in the lower left corner of the screen.


    Illustration 25g02724848

  6. Select the flow limit valves to calibrate and press the "Begin" button.


    Illustration 26g02724853

  7. Follow the instructions on the screen. Press "Next" button to continue through to the next step.


    Illustration 27g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve

  8. Set the main pump pressure using load valve (5) on the flow meter. Use the arrows to adjust the flow.

  9. Press and hold the control input for activation of the work tool to the FULL ON position during calibration.

  10. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  11. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 120 ± 2 L/min (31.7 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  12. Repeat Steps 10 and 11 until the flow meter reads 120 ± 2 L/min (31.7 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  13. Press the "NEXT" button.

  14. Set the main pump pressure using load valve (5) on the flow meter to 16000 ± 500 kPa (2321 ± 73 psi).

  15. Use the arrows to adjust the flow until the flow reading for the flow limit valve is at 180 ± 2 L/min (47.6 ± 0.5 gpm). Press the device for activation 3 times and release the device for activation 3 times for each adjustment.

  16. Repeat Steps 14 and 15 until the flow meter reads 180 ± 2 L/min (47.6 ± 0.5 gpm) and the pressure gauge reads 16000 ± 500 kPa (2321 ± 73 psi).

  17. Press the "NEXT" button.

  18. If the calibration was successful and no errors occurred, the display will indicate that the calibration is complete. Press the "Finish" button to exit or move on to the next calibration.

  19. If the calibration failed, the calibration is not saved. Press the "Restart" button to try the calibration again or press the "Finish" button to exit or move on to the next calibration.

Test Procedure

Confirm the calibration using the following procedure and specifications. Refer to Table 3 for the load pressure and flow specifications.



    Illustration 28g02726867

  1. Select "Diagnostic Tests" from the "Diagnostics" menu.


    Illustration 29g02726886

  2. Highlight "Main Pump Flow Limitation Pressure Test" and click on the "Start" button in the lower left corner of the screen.


    Illustration 30g02726938

  3. Select the test and press the "Begin" button.


    Illustration 31g02726940

  4. Follow the instructions on the screen. Press "Start" button in the lower left corner to begin the test.


    Illustration 32g02283033
    Portable hydraulic tester (flow meter)
    (5) Load valve

  5. Set the main pump pressure using load valve (5) on the flow meter. Use the arrows to adjust the flow. Refer to Table 3 for the load pressures and flow specifications.

Table 3
"Solenoid Valve (Proportional Reducing) - Calibrate (Flow Limit Valves)" 
Machine Settings  Engine Speed 
Engine speed dial "10"
AEC switch OFF
Flow set using Diagnostic Tests in Cat ET  Load pressure applied with flow meter 
12000 kPa (1740 psi) 16000 kPa (2321 psi) 20000 kPa (2901 psi) 
Flow Specifications
One Pump Flow  120 L/min (31.7 US gpm)  114 to 126 L/min (30.1 to 33.3 US gpm)  114 to 126 L/min (30.1 to 33.3 US gpm)  114 to 126 L/min (30.1 to 33.3 US gpm) 
160 L/min (42.3 US gpm) 152 to 168 L/min (40.1 to 44.4 US gpm)  152 to 168 L/min (40.1 to 44.4 US gpm)  152 to 168 L/min (40.1 to 44.4 US gpm) 
190 L/min (50.2 US gpm) 180 to 200 L/min (47.6 to 52.8 US gpm)  180 to 200 L/min (47.6 to 52.8 US gpm)  180 to 200 L/min (47.6 to 52.8 US gpm) 
Two Pump Flow  180 L/min (47.6 US gpm)  171 to 189 L/min (45.2 to 49.9 US gpm)  171 to 189 L/min (45.2 to 49.9 US gpm)  171 to 189 L/min (45.2 to 49.9 US gpm) 
200 L/min (52.8 US gpm) 190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm)  190 to 210 L/min (50.2 to 55.5 US gpm) 
220 L/min (58.1 US gpm) 209 to 231 L/min (55.2 to 61.0 US gpm)  209 to 231 L/min (55.2 to 61.0 US gpm)  209 to 231 L/min (55.2 to 61.0 US gpm) 

Caterpillar Information System:

3500B Engines for Caterpillar Built Power Modules Water Pump
C15 Petroleum Generator Set Engines Fuel Pressure Sensor
349F and 352F Excavators Machine System Specifications Relief Valve (One-Way Hydraulic Flow)
C4.4 Industrial Engine Crankshaft Gear (Balancer Drive) - Remove and Install
3500B Engines and 776D, 777D, 784C, 785C, 789C, 793C and 793D Off-Highway Truck/Tractors Engine Oil Pan
C13, C15, and C18 Tier 4 Final Engines Valve Mechanism Cover
C13, C15, and C18 Tier 4 Final Engines Valve Mechanism Cover
C13, C15, and C18 Tier 4 Final Engines Engine Oil Filter Base
3500B Engines and 776D, 777D, 784C, 785C, 789C, 793C and 793D Off-Highway Truck/Tractors Engine Oil Cooler Bypass and Cooling Jet Sequence Valves
XQ400 Power Module Gas Pressure Regulator Condensation - Drain
CG137-08 and CG137-12 Engines Coolant Level - Check
C15 Generator Sets Model View Illustrations
320E, 320F, 323E, 323F, 324E, 326F, 329E, 329F and 330F Excavators Tool Control System Combined Function - Electric Control: Relief Valve (Line) - Test and Adjust
320E, 320F, 323E, 323F, 324E, 326F, 329E, 329F and 330F Excavators Tool Control System Combined Function - Electric Control: Default Value of Work Tool Parameters
C175-16 Petroleum Engines Exhaust Manifold
C13, C15, and C18 Tier 4 Final Engines Housing (Front)
C175-16 Marine Propulsion Engines Fuel Lines
C175-16 Petroleum Engines Flexible Coupling
3500B Engines and 776D, 777D, 784C, 785C, 789C, 793C and 793D Off-Highway Truck/Tractors Piston and Rings - Two-Piece Piston
C175-16 Locomotive Engine Engine Oil Lines
301.5, 301.6, 301.7 CR, 301.8 and 302 CR Mini Hydraulic Excavators Before Starting Engine
C175-16 Marine Propulsion Engines Pressure Sensor
3512E Land Electric Drive Monitoring System
CD44B and CD54B Vibratory Asphalt Compactors Fuel Tank Strainer - Clean