773F, 773F OEM, 777F and 777F OEM Off-Highway Trucks and 775F and 775F OEM Quarry Truck Vital Information Management System (VIMS) Caterpillar


MID 053 - CID 0590 - FMI 09

Usage:

775F DLS
Conditions Which Generate This Code:


Illustration 1g01960840

Schematic of the data link

773F and 775F




Illustration 2g01960839

Schematic of the data link

777F

This diagnostic code is recorded when Advisor ECM does not receive expected information from Engine ECM through Cat Data Link for more than 5 seconds.

System Response:

This failure results in events that are logged against an ECM that cannot be explained directly. The Advisor ECM cannot communicate with this ECM or the ECM appears to communicate intermittently.

Test Step 1. VERIFY THE HARDWARE AND THE SOFTWARE PART NUMBERS.

  1. Verify that the following information is correct:

    • The part number of the "Advisor ECM onboard software"

    • The part number of the "Engine ECM flash software"

    • The part number of the Advisor ECM

    • The part number of the Engine ECM

    Note: Consult the Business Unit that produces the product for the correct part numbers of the configuration software.

Expected Result:

All part numbers are correct.

Results:

  • OK - All part numbers are correct. Proceed to test step 2.

  • NOT OK - All part numbers are NOT correct.

    Repair: The installed Advisor ECM or the Engine ECM has the wrong part number or the incorrect configuration software is installed. Replace the incorrect Advisor ECM or the Engine ECM with a module that has the correct part number. Flash the correct configuration software. See the Testing and Adjusting, "Electronic Control Module (ECM) - Flash Program" section of this manual.

    STOP

Test Step 2. INSPECT THE HARNESS CONNECTIONS.

  1. Turn the disconnect switch to the OFF position.

  1. Inspect all harness connections that are related to the Cat Data Link. Make sure that the connectors are clean and tight.

  1. Check the connectors for proper mating. Ensure that all the seals are present and in place.

  1. Check the harness for signs of damage or abrasion.

  1. Check the wires at the connector. Ensure that the wires are secured tightly into the connector. Take care not to pull the wire out of the connector.

  1. Check the exposed wires at the connectors for nicks or signs of abrasion.

  1. Check for moisture inside the connector.

  1. Check the connectors for dirty contacts or corroded contacts.

  1. Check each pin and each socket of the machine harness connectors. Ensure that the contacts are properly installed. The contacts should mate correctly when the two pieces of the connector are placed together.

Expected Result:

The machine harness connectors are tight and free of corrosion.

Results:

  • OK - The machine harness connectors are tight and free of corrosion. Proceed to test step 3.

  • NOT OK - The machine harness connectors are in need of repair.

    Repair: Repair the machine harness or replace the machine harness.

    STOP

Test Step 3. CHECK FOR SHORTS TO GROUND

  1. The disconnect switch remains in the OFF position.

  1. Disconnect the machine harness from all electronic control modules that use the Cat Data Link.

  1. At the machine harness for the Advisor ECM, measure the resistance between frame ground and connector contacts 8 (wire 893-GN) and connector contact 9 (wire 892-BR) of the Cat Data Link circuit.

Expected Result:

The resistance is greater than 5000 ohms.

Results:

  • OK - The resistance is greater than 5000 ohms. The harness circuit resistance is correct. Proceed to test step 4.

  • NOT OK - The resistance is less than 5000 ohms. The machine harness has failed.

    Repair: There is a short between frame ground and the Cat Data Link circuit in the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 4. CHECK FOR SHORT TO +BATTERY

  1. The disconnect switch remains in the OFF position.

  1. All related electronic control modules remain disconnected from the machine harness.

  1. At the machine harness connector for the Advisor ECM, perform the checks that are listed here:

    • Measure the resistance between the +Battery connector contact 1 (wire 113-OR) and connector contact 8 (wire 893-GN).

    • Measure the resistance between connector contact 1 (wire 113-OR) and connector contact 9 (wire 892-BR).

Expected Result:

The resistance is greater than 5000 ohms.

Results:

  • OK - The harness circuit resistance is correct. Proceed to test step 5.

  • NOT OK - The resistance is less than 5000 ohms. The machine harness has failed.

    Repair: There is a short between the +battery and the Cat Data Link circuit in the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 5. CHECK FOR OPEN HARNESS

  1. The disconnect switch remains in the OFF position.

  1. All related electronic control modules remain disconnected from the machine harness.

  1. Check the continuity of the Cat Data Link circuit in the machine harness:

    • Measure the resistance between connector contact 8 (wire 893-GN) of the Advisor ECM and connector contact J1-8 (wire 893-GN) of the Engine ECM.

    • Measure the resistance between connector contact 9 (wire 892-BR) of the Advisor ECM and connector contact J1-9 (wire 892-BR) of the Engine ECM.

Expected Result:

The resistance measures less than 5 ohms.

Results:

  • OK - The resistance is less than 5 ohms. The Cat Data Link circuit in the machine harness is correct. Proceed to test step 6.

  • NOT OK - The resistance is greater than five Ohms. The machine harness has failed.

    Repair: The Cat Data Link circuit is open in the machine harness. Repair the machine harness or replace the machine harness.

    STOP

Test Step 6. CHECK FOR ADDITIONAL DIAGNOSTIC CODES FOR THE OTHER ELECTRONIC CONTROL MODULES.

  1. Reconnect all the electronic control modules that use the Cat Data Link.

  1. Turn the disconnect switch and the key start switch to the ON position.

  1. Check the Event List for diagnostic codes that are logged against the other electronic control modules.

Expected Result:

Diagnostic codes are not present for the other electronic control modules in the event list.

Results:

  • OK - Diagnostic codes are not present for the other electronic control modules (ECM) in the event list.

    Repair: The Engine ECM has failed. The failure of the ECM is unlikely. Exit this procedure. Perform this procedure again. If the failure is not found, replace the ECM. See the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" section of this manual.

    STOP

  • NOT OK - Diagnostic codes are present for the other electronic control modules in the event list.

    Repair: The Advisor ECM has failed. The failure of the ECM is unlikely. Exit this procedure. Perform this procedure again. If the failure is not found, replace the ECM. See the Testing and Adjusting, "Electronic Control Module (ECM) - Replace" section of this manual.

    STOP

Caterpillar Information System:

793D Off-Highway Truck Air System and Brakes Air Tank (Primary)
D6K Track-Type Tractor Electrohydraulic Power Train Track
D6K Track-Type Tractor Electrohydraulic Power Train Track Idler
C175-16 and C175-20 Engines for Off-Highway Trucks Engine Oil Pressure - Test
12M Motor Grader Scarifier Digging Angle - If Equipped
12M Motor Grader Drawbar Ball and Socket End Play - Check/Adjust
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input Low Error IQAN XT2 A0-21
12M Motor Grader Drawbar Ball and Socket - Lubricate
Procedure for "Off-Board" Filtering Backhoe Loader and Integrated Toolcarrier Hydraulic Oil Equipped with Auxiliary Lines{0680, 0768, 5050, 5056, 5057} Procedure for "Off-Board" Filtering Backhoe Loader and Integrated Toolcarrier Hydraulic Oil Equipped with Auxiliary Lines{0680, 0768, 5050, 5056, 5057}
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input High Error IQAN XT2 A0-24
AP600D, AP655D, BG600D and BG655D Asphalt Pavers System Schematic
69D, 769D, 773D, 773E, 776D and 777D Off-Highway Trucks and 771D, 775D and 775E Quarry Trucks Power Train Electronic Control System System Schematic
793D Off-Highway Truck Power Train Transmission Planetary - Disassemble
793D Off-Highway Truck Power Train Transmission Planetary - Assemble
773F, 773F OEM, 777F and 777F OEM Off-Highway Trucks and 775F and 775F OEM Quarry Truck Vital Information Management System (VIMS) MID 053 - CID 1273 - FMI 09
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input Low Error IQAN XT2 A0-22
140M Motor Grader Engine Oil Level - Check
814F Series 2 Wheel Dozer, 815F Series 2 Soil Compactor and 816F Series 2 Landfill Compactor Power Train Input Components
12M Motor Grader Access Doors and Covers
C7 Engines for Caterpillar Built Machines Valve Mechanism
TK711, TK721, TK722, TK732, TK741, TK751 and TK752 Track Feller Bunchers IQAN MDM Monitor Fault ; Event Codes Input Low Error IQAN XT2 A0-23
966H and 972H Wheel Loaders Steering Column Spline (Command Control Steering) - Lubricate
773D and 777D Off-Highway Truck/Tractors Power Train Electronic Control System Sound Limit Function
773D and 777D Off-Highway Truck/Tractors Power Train Electronic Control System Hoist Lower Valve - Adjust
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.