Illustration 1 | g01228467 |
Illustration 2 | g01228487 |
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25 °C (77 °F)
- Speed ... 7018 ± 1517 rpm
- Current ... 147 ± 27.2 amp
- Voltage ... 11 V
- Current ... 147 ± 27.2 amp
(1) Tighten the nut on the battery terminal to the following torque. ... 30.5 ± 3.5 N·m (23 ± 3 lb ft)
(2) Tighten the ground terminal to the following torque. ... 30.5 ± 3.5 N·m (22 ± 3 lb ft)
(3) Tighten the nut to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Tighten the nut on the switch terminal to the following torque. ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Tighten the nut on the motor terminal to the following torque. ... 14.7 ± 3.4 N·m (11 ± 3 lb ft)
(6) Tighten the nut on the motor frame terminal to the following torque. ... 8 ± 3 N·m (71 ± 27 lb in)
Solenoid
Current draw at 10 V and 25 °C (77 °F)
- Pull-in windings ... 74 amp
- Hold-in windings ... 19 amp