- Excavator:
- 320 (S/N: 9WG1-UP; 4ZJ1-UP; 3RK1-UP; 3XK1-UP; 4BK1-UP; 7WK1-UP; 9KK1-UP; 1TL1-UP; 1XM1-UP)
- 320B (S/N: BBG1-UP; BNP1-UP; 4NR1-UP; 5BR1-UP; 6CR1-UP; 7JR1-UP; 1XS1-UP; 2AS1-UP; 5MS1-UP; 6LS1-UP; 9JS1-UP; 9WS1-UP; 4XW1-UP; 5GW1-UP; 6LW1-UP; 3YZ1-UP; 7ZZ1-UP; 8GZ1-UP)
- 320C (S/N: BEA1-UP; BDE1-UP; BCN1-UP)
- 320S (S/N: 6KM1-UP)
- 321B (S/N: KGA1-UP; AKG1-UP; 9CZ1-UP)
- 322 (S/N: 7WL1-UP)
- 322 L (S/N: 8CL1-UP)
- 322B (S/N: 3NR1-UP; 5CR1-UP; 8MR1-UP; 8NR1-UP; 1AS1-UP; 1YS1-UP; 1ZS1-UP; 2ES1-UP)
- 322C (S/N: BFK1-UP)
- 322L (S/N: 8ML1-UP; 9RL1-171; 4RM1-UP)
- 322N (S/N: 9JL1-UP)
- 325 (S/N: 7TG1-UP; 8JG1-UP; 9SG1-UP; 7LJ1-UP; 2SK1-UP; 5WK1-UP; 8NK1-UP; 8YK1-UP; 9ZK1-141; 2SL1-516; 3LL1-676; 8NL1-UP; 6RM1-86; 7LM1-336,345-348)
- 325B (S/N: 8GM1-UP; 6DN1-UP; 7EN1-UP; 8FN1-UP; 2JR1-UP,1-1638,1639-UP; 8PR1-UP; 8RR1-UP; 1GS1-UP; 4DS1-UP; 5BS1-UP)
- 325L (S/N: 7CJ1-UP; 2JK1-UP; 9KL1-UP)
- 330 (S/N: 9NG1-UP; 6WJ1-UP; 9PJ1-UP; 9WJ1-UP; 6SK1-UP; 6ZK1-UP; 8CK1-UP; 8FK1-UP; 2EL1-UP; 8RL1-UP; 2ZM1-UP; 5YM1-UP)
- 330B (S/N: 9HN1-UP; 2RR1-UP; 3YR1-UP; 5LR1-UP; 6DR1-1582,1583-3728,3729-4054,4055-UP; 8SR1-UP; 8TR1-UP; 1JS1-UP; 4RS1-UP; 5LS1-UP; 5EZ1-UP)
- 330C (S/N: CYA1-UP; HAA1-UP; MCA1-199,200-UP; JAB1-430,431-457,458-UP; D3C1-UP; JCD1-268,269-UP; KDD1-323,324-350,351-UP; GAG1-UP; RBH1-UP; B1K1-UP; JNK1-202,203-UP; B2L1-UP; BTM1-UP; B3M1-UP; MKM1-299,300-UP; B4N1-UP; CAP1-597,598-UP; GKX1-143,144-UP; DKY1-693,694-927,928-UP; CGZ1-279,280-UP)
- 330D (S/N: RDA1-UP; KAB1-UP; GBC1-UP; NBD1-UP; GGE1-UP; B6H1-UP; THJ1-UP; FFK1-UP; L2K1-UP; PCK1-UP; ERN1-UP; JLP1-UP; MWP1-UP; LDR1-UP; HAS1-UP; RAS1-UP; EDX1-UP; MEY1-UP; T2Y1-UP)
- 330L (S/N: 9ML1-UP)
- 345B Series II (S/N: ALB1-UP; APB1-UP; CCC1-692; ALD1-UP; AMD1-UP; AKJ1-UP; AMJ1-UP; CDJ1-UP; AYR1-UP; AGS1-UP; DET1-UP; DCW1-UP; AKX1-UP)
- 345B (S/N: CFM1-UP; 4SS1-UP; 6XS1-UP; 7KS1-UP; 9GS1-UP; 2NW1-UP; 2SW1-UP; 6MW1-UP; 8KW1-UP; 8RW1-UP; 9CW1-UP)
- E120B (S/N: 6JF1-UP)
- UNDERCARRIAGE (S/N: L5J1-UP; L5N1-UP)
- 320B (S/N: BBG1-UP; BNP1-UP; 4NR1-UP; 5BR1-UP; 6CR1-UP; 7JR1-UP; 1XS1-UP; 2AS1-UP; 5MS1-UP; 6LS1-UP; 9JS1-UP; 9WS1-UP; 4XW1-UP; 5GW1-UP; 6LW1-UP; 3YZ1-UP; 7ZZ1-UP; 8GZ1-UP)
- Knuckleboom Loader:
- 539 (S/N: 1PZ1-UP)
- Track Feller Buncher:
- TK1161 (S/N: TKD1-UP)
- TK1162 (S/N: TKE1-UP)
- TK711 (S/N: TKA1-UP)
- TK721 (S/N: TKB1-UP)
- TK722 (S/N: TKC1-UP)
- TK1162 (S/N: TKE1-UP)
- Mobile Hydraulic Power Unit:
- 330C MHPU (S/N: MSD1-UP)
- Paving Compactor:
- CP-433C (S/N: 4JZ1-UP)
- Track-Type Loader:
- 953C (S/N: BBX1-UP)
- 963C (S/N: BBD1-UP; 2DS1-UP)
- Wheel Tractor-Scraper:
- 621G (S/N: ALP1-UP)
- Wheeled Excavator:
- M325B (S/N: BGN1-UP)
- W330B (S/N: AME1-UP)
- W345B Series II (S/N: ANJ1-UP; CDY1-UP)
- W330B (S/N: AME1-UP)
Introduction
Summary of Changes in REHS1682     | |
11     | Added 311-9541 Main Hydraulic Pump Gp to document.     |
10     | Removed Fabricated Tooling Section.     |
Included tooling 457-2323 in Table 44. | |
09     | Added callouts to Illustration 7.     |
Deleted Excavator serial number prefix SSL to document. | |
08     | Added Excavator serial number prefix SSL to document.     |
07     | Added ""Canceled Part Numbers and Replaced Part Numbers" " section to document.     |
Added REHS1761 "Required Tooling for Bench Testing Hydraulic Components" to ""References" " section of document. |
© 2015 Caterpillar All Rights Reserved. This guideline is for the use of Caterpillar Dealers only. Unauthorized use of this document or the proprietary processes therein without permission may be violation of intellectual property law. Information in this document is considered Caterpillar: Confidential Yellow.
This Special Instruction includes test procedures for piston pumps. This Special Instruction also provides specifications. The technician should have a good understanding of hydraulic piston pumps. The technician should be educated in the operation of the hydraulic test bench. The test benches that are in this document are available through the Caterpillar Service Tool Division. Gather all necessary tooling before you need to hook up the pump. Some of the required tooling appears in a table at the end of this document. There are many possible variations of tooling that could be used. Not every possible variation can be listed.
For questions or additional information concerning this guideline, submit a feedback form in the Service Information System website. In order to address an urgent need, use the following to relay your request to Caterpillar Repair Process Engineering:
- Cat Dealer Technical Communicator
- Dealer Solution Network
- Cat Technical Representative
- Knowledge Network (online)
Canceled Part Numbers and Replaced Part Numbers
This document may not include all Canceled part numbers and replaced part numbers. Use NPR on SIS for information about Canceled part numbers and replaced part numbers. NPR will provide the current part numbers for replaced parts.
Safety
Illustration 1 | g02139237 |
Personal injury or death can result from improperly checking for a leak. Always use a board or cardboard when checking for a leak. Escaping air or fluid under pressure, even a pin-hole size leak, can penetrate body tissue causing serious injury, and possible death. If fluid is injected into your skin, it must be treated immediately by a doctor familiar with this type of injury. |
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin. |
Pump test pressures in this guideline may exceed the normal operating range of the hydraulic test hoses utilized when connecting the tested pump to the test bench. However, the order of magnitude of these pressures is significantly below the burst strength of the Caterpillar "XT6" product. High pressure oil can escape through improperly assembled hoses and fittings. High pressure oil can also escape through poorly maintained hoses and fittings. High pressure oil may also leak through hose that has become damaged over the life of the hose due to the pressure levels that occur during test bench operation. Personal injury or death can result from improper hose & fitting inspection or improper hose replacement procedures. Escaping fluid under pressure can penetrate body tissue causing serious injury, and possible death. Thoroughly inspect all testing hoses, fittings, and quick disconnects prior to any testing operation. Check the assembly date tag or hose assembly log date for a hose life indicator. Replace all Test Bench hoses at a minimum of every 2 years or earlier if the hose or fittings appear to be damaged. |
Summary
This procedure is specific to the type of pump and the type of control. Refer to the test specifications and the tooling at the end of this document.
Note: A paper copy of this document may not be the latest version. Go to the Service Information System (SIS) in order to view the latest version.
References
References     | |
---|---|
Media Number     | Title     |
REHS1761     | Required Tooling for Bench Testing Hydraulic Components     |
SEBF8810     | Hydraulic Pump, Motor, and Cylinder Bench Test Procedure Reference Manual     |
SEHS8892     | Operating Instructions for Caterpillar 1U-9400 Series Hydraulic Test Center     |
NEHS0563     | Tool Operating Manual for 9U-5000 Series Hydraulic Test Bench     |
Connections for the Caterpillar Hydraulic Test Center
Illustration 2 | g01126726 |
Connections for the test center (1) Flow control for discharge (2) "F3" flow meter inlet (3) "F4" flow meter inlet (4) Oil supply from the auxiliary pump (5) "F3" inlet for the flow meter with flow limiter (6) "F3"outlet for the flow meter with pressure control (7) Load sensing pressure (8) Signal pressure (9) "F4" outlet for the flow meter (10) Return to tank (11) Connections for case drain (12) Oil supply |
Illustration 3 | g01126727 |
Control and gauges for the test center (13) Meter for speed and torque (14) Gauge for signal pressure (15) Control for signal pressure (16) Pressure gauge for auxiliary pump (17) Auxiliary pump flow (18) "F3" discharge pressure gauge (19) "F3" discharge flow (20) "F4" discharge pressure gauge (21) "F4" discharge flow (22) Auxiliary pump flow control (23) "F3" margin pressure (24) "F3" Load control for discharge pressure (25) "F4" Load control for discharge pressure |
Connections for the Caterpillar Hydraulic Test Bench
Illustration 4 | g01126729 |
Connections for the test bench (26) "Flow meter 1" loop and "Flow meter 2" loop (27) Oil supply |
Illustration 5 | g01126732 |
Connections for the test bench (28) "Flow meter 2" loop (29) "Flow meter 1" loop (30) "Flow meter 2" outlet (31) Signal pressure line (32) "Flow meter 2" inlet (33a) "Flow meter 1" outlet (33b) Outlet for the auxiliary oil supply (34) Inlet for the auxiliary oil supply (35) "Flow meter 1" inlet |
Illustration 6 | g01126738 |
Control and gauges for the test bench (36) Auxiliary oil supply pressure (37) Signal pressure (38) Control for signal pressure (39) "Flow meter 1" discharge pressure (40) Control for auxiliary oil supply pressure (41) "Flow meter 2" discharge pressure (42) Auxiliary oil supply control (43) "Flow meter 2" discharge flow (44) Discharge flow for auxiliary pump (45) "Flow meter 1" discharge flow (46) "Flow meter 1" load control (47) Speed and direction control (48) "Flow meter 2" load control |
Port Locations
This piston pump is produced with multiple housings. Port locations will vary. Match the correct illustration with the pump being worked on.
Illustration 7 | g01126749 |
Typical port locations and adjustments for type 1 and type 2 pumps (49) Discharge port for the pilot pump (50) Pressure port for negative flow control (51) Adjustment screw for negative flow control (52) Adjustment screw for constant power (53) Pressure port for power shift (54) Discharge ports (55) Suction port (56) Adjustment screw for maximum displacement (57) Case vent plug |
Illustration 8 | g03540965 |
Typical port locations and adjustments for the type 3 pump (49) Discharge port for the pilot pump (50) Pressure port for negative flow control (51) Adjustment screw for negative flow control (52) Adjustment screw for constant horsepower (53) Pressure port for power shift (54) Discharge ports (55) Suction port (56) Adjustment screw for maximum displacement (57) Case vent plug |
Illustration 9 | g01328797 |
Hydraulic schematic for pump types 1 and 2 (49) Discharge port for the pilot pump (50) Pressure port for negative flow control (51) Adjustment screw for negative flow control (52) Adjustment screw for constant horsepower (53) Pressure port for power shift (54) Discharge ports (55) Suction port (56) Adjustment screw for maximum displacement (57) Case vent plug |
Note: (Pump Numbers:7I-7590, 7Y-4002, 7Y-4009, 087-4828, 114-0602, 114-0603, 114-0604, 114-0605, 1140662,123-1993, 123-2229, 123-2231, 123-2233, 123-2235, 128-9062, 153-9184, 153-9185, 159-7779, 162-0917, 165-9322, 171-3239, 185-0220, 200-3550, 216-0032, 222-0103, 222-0107, 222-0108, 222-0109, 222-0110, 242-6779)
Illustration 10 | g01328702 |
Hydraulic schematic for pump type 3 (49) Discharge port for the pilot pump (50) Pressure port for negative flow control (51) Adjustment screw for negative flow control (52) Adjustment screw for constant horsepower (53) Pressure port for power shift (54) Discharge ports (55) Suction port (56) Adjustment screw for maximum displacement (57) Case vent plug |
Note: (Pump Numbers: 216-0038, 194-8383)
1U-6392 Pressure Reducing Valve
Illustration 11 | g01127628 |
1U-6392 Pressure Reducing Valve (58) Adjustment screw for the outlet pressure (59) Outlet port to tank (60) Gauge port for the inlet pressure |
Illustration 12 | g01127631 |
1U-6392 Pressure Reducing Valve (61) Port for the outlet pressure (62) Gauge port for the outlet pressure (63) Port for the inlet pressure |
Pressure Relief Valve
Illustration 13 | g01033328 |
120-9181 Valve Body and the 4C-4014 Pressure Relief Cartridge |
Illustration 14 | g01040342 |
Schematic for a pressure relief valve |
Pump Pre-Test Set Up
- Install quick disconnect fittings in the pressure port for negative flow control (50) and the power shift pressure port (53). Refer to the Illustrations 7 and 7.
Vent both pressure ports for negative flow control (50) to the atmosphere. Connect the signal pressure oil supply from the test bench to the power shift pressure port (53) .
- Connect both pump discharge ports (54) to the individual flow meter loops on the test bench.
- Connect the discharge port for the pilot pump (49) to an in-line flow meter in order to measure the discharge of the pilot pump.
- Connect the pump suction port (54) to the test bench oil supply.
- Purge all air from the suction line before rotating the pump. Loosen the suction hose at the pump until oil leaks from the connection. Tighten the suction hose.
- Carefully loosen the case vent plug (57). This will release the air pressure of the case in order to allow the case to fill with oil from the suction line.
- Make sure that the pump case is full of oil before rotating. Secure the case vent plug (57).
- Do not rotate the pump in the wrong direction. The correct direction of rotation will be stated on the pump. The direction of rotation is viewed from the input shaft end. Visually check the pump for proper rotation.
Test Procedure
Note: The steps in the procedure correlate with the steps under the test specifications according to your specific part number.
The hydraulic oil in the test bench should meet a contamination rating of ISO 16/13 or cleaner. The oil in the test bench should be one of the following.
- SAE 10W at 50 °C (122 °F) or
- Mobil DTE-11 at 46 °C (115 °F)
Illustration 15 | g01127676 |
- Start rotating the pump according to Step 1 of the test specifications. Listen for abnormal noise and verify flow from the pilot pump discharge port (49). Verify that all connections are tight. Check for leaks around shaft seals. Check for leaks around the control valve.
Run the pump for at least 5 minutes in order to raise the temperature of the oil and purge the system of air.
Load the pilot discharge to the value in the test specifications.
- Use the following steps to verify that the constant horsepower is operating properly and that the maximum displacement is set. Both pumps will be tested at the same time. Compare the flow rates at each step to the values in the test specifications. Refer to the Illustration 15 for an example of the horsepower curve.
- Increase the input RPM, signal pressure from the test bench to the power shift pressure port (53) according to Step 2.a of the test specifications.
Adjust the adjustment screw for maximum displacement (56) if the discharge flow is not within specifications. Loosen the locknut and turn the adjustment screw for maximum displacement (56) counterclockwise in order to increase the flow. Turn the adjustment screw for the maximum displacement (56) clockwise in order to decrease the flow.
- Use the test bench to load both pumps to the value in Step 2.b of the test specifications.
This is the destroke point. The pumps should now be under constant horsepower control. Slowly cycle the load to both pumps to the value in Step 2.b of the test specifications. This step verifies that the pump is starting to destroke. When the pump discharge pressure increases to a value more than Step 2.b of the test specifications the discharge flow should begin dropping. Adjust the screw for constant horsepower (52) if the point of destroke of either pump is not correct.
Loosen the locknut on the adjustment screw for constant horsepower (52). Turn the adjustment screw for constant horsepower (52) clockwise in order to increase the flow rate to the value in the test specifications. Turn the adjustment screw for constant horsepower (52) counterclockwise in order to decrease the flow rate to the value in the test specifications.
- Load the pump by using the test bench to the value in Step 2.c of the test specifications.
- Load the pump by using the test bench to the value in Step 2.d of the test specifications.
Note: Disassemble the pump control and install new springs if the discharge rates in Steps 2.c and 2.d are not within the specifications.
- Increase the input RPM, signal pressure from the test bench to the power shift pressure port (53) according to Step 2.a of the test specifications.
- Verify the operation of the control of negative flow by using the following steps. Both pumps will be tested at the same time. Compare the flow rates at each step to the values in the test specifications. Refer to Illustration 17 for an example of a curve of negative flow control.
Decrease the input rpm and all pressures to zero. Disconnect the signal pressure of the test bench from the power shift pressure port (53). Vent the power shift pressure port (53) to the atmosphere. Connect the pressure ports for the negative flow control (50) to the signal pressure of the test bench by using a 196-8722 Tee (64) as indicated by Illustration 16.
- Increase the input rpm and discharge pressure to both pump discharge ports (54). Increase signal pressure from the test bench to the negative pressure ports for flow control (50) according to Step 3.a of the test specifications.
This is the destroke point. The pump should now be under negative flow control. Slowly cycle both pumps' pressure for the negative flow control to the value in Step 3.a of the test specifications. This verifies that the pump is starting to destroke. When the negative flow control pressure increases to a value more than Step 3.a of the test specifications the discharge flow should begin dropping. Adjust the adjustment screw for the negative flow control (51) if either pump's point of destroke is not correct.
Loosen the locknut in order to adjust the adjustment screw for negative flow control (51). Turn the adjustment screw for negative flow control (51) counterclockwise in order to increase the flow rate to the value in the test specifications. Turn the adjustment screw for negative flow control (51) clockwise in order to decrease the flow rate to the value in the test specifications.
- Increase negative flow control pressure to the pressure port for negative flow control (50) according to Step 3.b of the test specifications.
- Increase the negative flow control pressure to the pressure port for negative flow control (50) according to Step 3.c of the test specifications.
- Increase the input rpm and discharge pressure to both pump discharge ports (54). Increase signal pressure from the test bench to the negative pressure ports for flow control (50) according to Step 3.a of the test specifications.
Illustration 16 | g01111841 |
Set up for Steps 3.a through 3.c of the test procedure (64) 196-8722 Tee |
Illustration 17 | g01046495 |
- For this test, only one pump will be tested at a time. The pump that is not being tested will remain at standby.
Decrease the input rpm and all pressures to zero. Remove the signal pressure from the test bench to the pump that is being tested. Vent the negative flow control pressure ports (50) to the atmosphere. Connect signal pressure from the test bench to the power shift pressure port (53). Connect the 1U-6392 Pressure Reducing Valve outlet (61) to the pressure port for negative flow control (50) to the pump on standby. Connect the 1U-6392 Pressure Reducing Valve inlet (60) to a pressure port from the standby pump.
Increase the input rpm to the value in Step 4 of the test specifications. Apply signal pressure to the power shift pressure port (53) according to the value in Step 4 of the test specifications. Load the stand by pump to the pressure value in Step 4 of the test specifications. Increase the negative flow control pressure to the negative flow control pressure port (50) on the pump at standby.
Record the discharge rate of the test pump.
Illustration 18 | g01109964 |
Setting up pressure reducing valves for Steps 4 and 5 of the test procedure (61) Outlet from the 1U-6392 Pressure Reducing Valve (63) Inlet to the 1U-6392 Pressure Reducing Valve (65) 1U-6392 Pressure Reducing Valve |
- Load the pump by using the test bench to the value in Step 5 in the test specifications. Subtract the discharge flow in Step 5 from Step 4 of the test specifications. This value is internal leakage. The internal leakage should not exceed the value in Step 5 of the test specifications. If the internal leakage is too high, the pump may not be mechanically feasible and the pump should be disassembled and inspected in order to diagnose the problem.
Unload the pump and repeat Steps 4 and 5 for the other pump that has not been tested.
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin. |
Reduce RPM and all pressures to zero. Remove the component from the bench. Drain the oil from the pump. Plug all of the ports.
Test Specifications
Part Number     | 7I-7590     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 975     | 975     | 975     | 975     | 975     | 975     | 975     | 975     | 975     |
Power Shift Pressure kPa (psi)     | -     | 1860 (270)     | 0 (0)     | 370 (54)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1370 ±150 (199 ±22)     | 1860 (270)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 14900 (2161)     | 21760 (3156)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 29800 (4322)     | ||
Discharge Flow lpm (gpm)     | 63 (16.6)     | 102.5 ±3 (27± 0.8)     | 100 ±3 (26.4± 0.8)     | 62.5±5 (16.5± 1.3)     | 37.5±5 (9.9± 1.3)     | 101.5 ±3 (26.8± 0.8)     | 65±3 (17.2 ±0.8)     | 16.5±3 (4.4 ±0.8)     | 102.5 ±3 (27 ±0.8)     | 97±3 (25.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3720 (540)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11.5 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.84 (1.8)     | 11.1 (2.9)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 7Y-4002     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     |
Power Shift Pressure kPa (psi)     | -     | 1860 (270)     | 0 (0)     | 294 (43)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1370 ±150 (199 ±22)     | 1860 ±150 (270 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 15700 (2277)     | 23100 (3350 )     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 31400 (4554)     | ||
Discharge Flow lpm (gpm)     | 64 (17)     | 107 +0/-6 (28.3 +0/ -1.6)     | 104±3 (27.5 ±0.8)     | 63.5±5 (16.8 ±1.3)     | 40.5±5 (10.7 ±1.3)     | 105.5 ±6 (27.8 ±1.6)     | 65±3 (17.2 ±0.8)     | 16.5±3 (4.4 ±0.8)     | 107 +0/-6 (28.3 +0/ -1.6)     | 101 ±3 (26.7 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3720 (540)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Discharge Flow at Standby lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 8 (2.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.84 (1.8)     | 11.4 (3)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 7Y-4009     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1320 (191)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1620 ±150 (199 ±22)     | 2030 ±150 (294 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18300 (2654)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 77.5±3 (20.5 ±0.8)     | 55±3 (14.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 69±3 (18.2 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.42 (1.7)     | 9.6 (2.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 087-4828     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1760 (255)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1780 ±150 (258 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 14110 (2046)     | 20580 (2985)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 27240 (3950)     | ||
Discharge Flow lpm (gpm)     | 61 (16.2)     | 92.5 ±3 (24.4 ±0.8)     | 89 ±3 (23.5 ±0.8)     | 55 ±3 (14.5 ±0.8)     | 29 ±3 (7.7 ±0.8)     | 90.5±6 (23.9 ±1.6)     | 55 ±3 (14.5 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 85.5 ±3 (22.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3720 (540)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 13 (3.4)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.84 (1.8)     | 10.3 (2.7)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 114-0602     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1760 (255)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1780 ±150 (258 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 14110 (2046)     | 20580 (2985)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 27240 (3950)     | ||
Discharge Flow lpm (gpm)     | 61 (16.2)     | 92.5 ±3 (24.4 ±0.8)     | 89 ±3 (23.5 ±0.8)     | 55 ±3 (14.5 ±0.8)     | 29 ±3 (7.7 ±0.8)     | 90.5±6 (23.9 ±1.6)     | 55 ±3 (14.5 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 85.5 ±3 (22.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3720 (540)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 13 (3.4)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.84 (1.8)     | 10.3 (2.7)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 114-0603     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 975     | 975     | 975     | 975     | 975     | 975     | 975     | 975     | 975     |
Power Shift Pressure kPa (psi)     | -     | 1860 (270)     | 0 (0)     | 370 (54)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1370 ±150 (199 ±22)     | 1860 (270)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 14900 (2161)     | 21760 (3156)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 29800 (4322)     | ||
Discharge Flow lpm (gpm)     | 63 (16.6)     | 102.5 ±3 (27± 0.8)     | 100 ±3 (26.4± 0.8)     | 62.5±5 (16.5± 1.3)     | 37.5±5 (9.9± 1.3)     | 101.5 ±3 (26.8± 0.8)     | 65±3 (17.2 ±0.8)     | 16.5±3 (4.4 ±0.8)     | 102.5 ±3 (27 ±0.8)     | 97±3 (25.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3720 (540)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11.5 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.84 (1.8)     | 11.1 (2.9)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 114-0604     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     |
Power Shift Pressure kPa (psi)     | -     | 1860 (270)     | 0 (0)     | 294 (43)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1370 ±150 (199 ±22)     | 1860 ±150 (270 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 15700 (2277)     | 23100 (3350)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 31400 (4554)     | ||
Discharge Flow lpm (gpm)     | 64 (17)     | 107 +0/-6 (28.3 +0/ -1.6)     | 104±3 (27.5 ±0.8)     | 63.5±5 (16.8 ±1.3)     | 40.5±5 (10.7 ±1.3)     | 105.5 ±6 (27.8 ±1.6)     | 65±3 (17.2 ±0.8)     | 16.5±3 (4.4 ±0.8)     | 107 +0/-6 (28.3 +0/ -1.6)     | 101 ±3 (26.7 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3720 (540)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 8 (2.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.84 (1.8)     | 11.4 (3)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 114-0605     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3b     | 3c     | 3d     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1320 (191)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1620 ±150 (199 ±22)     | 2030 ±150 (294 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18300 (2654)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 77.5±3 (20.5 ±0.8)     | 55±3 (14.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 69±3 (18.2 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.42 (1.7)     | 9.6 (2.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 114-0662     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1320 (191)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1620 ±150 (199 ±22)     | 2030 ±150 (294 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18300 (2654)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 77.5±3 (20.5 ±0.8)     | 55±3 (14.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 69±3 (18.2 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.42 (1.7)     | 9.6 (2.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 123-1993     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1670 (242)     | 0 (0)     | 1080 (157)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1285 ±150 (186 ±22)     | 1795 ±150 (260 ±22)     | 3725 ±50 (540 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 14420 (2091)     | 21340 (3095)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 96 (25.4)     | 160 ±3 (42.3 ±0.8)     | 156 ±3 (41.2 ±0.8)     | 103.5 ±5 (27.3 ±1.3)     | 58 ±5 (15.3 ±1.3)     | 158 ±6 (41.7 ±1.6)     | 107.5 ±6 (28.4 ±1.6)     | 20 ±3 (5.3 ±0.8)     | 144 ±3 (38 ±0.8)     | 135.9 ±3 (35.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 18 ±3 (4.8 ±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 15 (4.0)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 19.0 (5.0)     | 17.1 (4.5)     | |||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 123-2229     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     |
Power Shift Pressure kPa (psi)     | -     | 1270 (184)     | 0 (0)     | 1000 (145)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1740 ±150 (252 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 15800 (2292)     | 22600 (3278)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 30700 (4452)     | ||
Discharge Flow lpm (gpm)     | 64 (17)     | 107 +0/-6 (28.3 +0/ -1.6)     | 104 ±3 (27.5 ±0.8)     | 67.5 ±5 (17.8 ±1.3)     | 43.5±5 (11.5 ±1.3)     | 105.5 ±6 (27.8 ±1.6)     | 69 ±6 (18.2 ±1.6)     | 16.5±3 (4.4 ±0.8)     | 107 +0/-6 (28.3 +0/ -1.6)     | 101 ±3 (26.7 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 8 (2.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 19.0 (5.0)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 123-2231     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 975     | 975     | 975     | 975     | 975     | 975     | 975     | 975     | 975     |
Power Shift Pressure kPa (psi)     | -     | 1570 (228)     | 0 (0)     | 1210 (175)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1230 ±150 (178 ±22)     | 1720 (250)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 14300 (2074)     | 21180 (3071)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 29220 (4238)     | ||
Discharge Flow lpm (gpm)     | 63 (16.6)     | 102.5 ±3 (27± 0.8)     | 100 ±3 (26.4± 0.8)     | 62.5±3 (16.5± 0.8)     | 36.5±3 (9.6± 0.8)     | 101.5 ±3 (26.8± 0.8)     | 65±3 (17.2± 0.8)     | 16.5±3 (4.4± 0.8)     | 102.5 ±3 (27± 0.8)     | 97±3 (25.6± 0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11.5 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3)     | 18.5 (4.9)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 2920 (570)     |
Part Number     | 123-2233     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1270 (184)     | 0 (0)     | 961 (139)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1780 ±150 (258 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 13440 (1949)     | 20100 (2915)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 26580 (3855)     | ||
Discharge Flow lpm (gpm)     | 61 (16.2)     | 92.5 ±3 (24.4 ±0.8)     | 89 ±3 (23.5 ±0.8)     | 55 ±3 (14.5 ±0.8)     | 28 ±3 (7.4 ±0.8)     | 90.5±6 (23.9 ±1.6)     | 55 ±3 (14.5 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 85.5 ±3 (22.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 13 (3.4)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 123-2235     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1120 (162)     | 0 (0)     | 980 (142)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1460 ±150 (212 ±22)     | 1740 ±150 (252 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18700 (2712)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 81.5±3 (21.5 ±0.8)     | 58.5 ±3 (15.4 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 86.5±3 (22.8 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 128-9062     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1320 (191)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1620 ±150 (199 ±22)     | 2030 ±150 (294 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18300 (2654)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 77.5±3 (20.5 ±0.8)     | 55±3 (14.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 69±3 (18.2 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.42 (1.7)     | 9.6 (2.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 153-9184     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     |
Power Shift Pressure kPa (psi)     | -     | 1270 (184)     | 0 (0)     | 1000 (145)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1740 ±150 (252 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 15800 (2292)     | 22600 (3278)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 30700 (4452)     | ||
Discharge Flow lpm (gpm)     | 64 (17)     | 107 +0/-6 (28.3 +0/ -1.6)     | 104 ±3 (27.5 ±0.8)     | 67.5 ±5 (17.8 ±1.3)     | 44.5±5 (11.7 ±1.3)     | 105.5 ±6 (27.8 ±1.6)     | 69 ±6 (18.2 ±1.6)     | 16.5±3 (4.4 ±0.8)     | 107 +0/-6 (28.3 +0/ -1.6)     | 101 ±3 (26.7 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 8 (2.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 19.0 (5.0)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 153-9185     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3b     | 3c     | 3d     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1120 (162)     | 0 (0)     | 980 (142)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1460 ±150 (212 ±22)     | 1740 ±150 (252 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18700 (2712)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 81.5±3 (21.5 ±0.8)     | 70 ±3 (18.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 86.5±3 (22.8 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 159-7779     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1320 (191)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1620 ±150 (199 ±22)     | 2030 ±150 (294 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18300 (2654)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 13700 (1987)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     |
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 77.5±3 (20.5 ±0.8)     | 55±3 (14.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 69±3 (18.2 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.42 (1.7)     | 9.6 (2.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 162-0917     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1270 (184)     | 0 (0)     | 961 (139)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1780 ±150 (258 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 13440 (1949)     | 20100 (2915)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 26580 (3855)     | ||
Discharge Flow lpm (gpm)     | 61 (16.2)     | 92.5 ±3 (24.4 ±0.8)     | 89 ±3 (23.5 ±0.8)     | 55 ±3 (14.5 ±0.8)     | 39 ±3 (10 ±0.8)     | 90.5±6 (23.9 ±1.6)     | 55 ±3 (14.5 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 85.5 ±3 (22.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 13 (3.4)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 165-9322     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 800     | 800     |
Power Shift Pressure kPa (psi)     | -     | 1370 (199)     | 0 (0)     | 940 (136)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1180 ±150 (171 ±22)     | -     | 3630 ±50 (526±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 7100 (1030)     | 14800 (2147)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 119 (31.6)     | 179.5 ±3 (47.4 ±0.8)     | 177.5 ±3 (46.8 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 43 ±3 (11.4 ±0.8)     | 177.5 ±6 (46.9 ±1.6)     | -     | 20 ±3 (5.3 ±0.8)     | 144.5 ±3 (38 ±0.8)     | 136 ±3 (35.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 17.8 ±3 (4.7 ±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 15.5 (4.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | 15.2 (4.0)     | |||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 171-3239     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1320 (191)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1620 ±150 (199 ±22)     | 2030 ±150 (294 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18300 (2654)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 77.5±3 (20.5 ±0.8)     | 55±3 (14.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 69±3 (18.2 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.42 (1.7)     | 9.6 (2.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3430 (500)     |
Part Number     | 185-0220     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 800     | 800     |
Power Shift Pressure kPa (psi)     | -     | 1370 (199)     | 0 (0)     | 940 (136)     | 940 (136)     | |||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1180 ±150 (171 ±22)     | -     | 3630 ±50 (526±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 7100 (1030)     | 14800 (2147)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 119 (31.6)     | 179.5 ±3 (47.4 ±0.8)     | 177.5 ±3 (46.8 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 43 ±3 (11.4 ±0.8)     | 177.5 ±6 (46.9 ±1.6)     | -     | 20 ±3 (5.3 ±0.8)     | 144.5 ±3 (38 ±0.8)     | 136 ±3 (35.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 17.8 ±3 (4.7 ±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 15.5 (4.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | 15.2 (4.0)     | |||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 194-8383 (1)     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Solenoid Amperage (mA)     | -     | 650     | -     | -     | -     | 650     | ||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 17.5 (4.6)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
( 1 ) | Note: This pump is equipped with a solenoid to control powershift. |
Part Number     | 200-3550     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3b     | 3c     | 3d     | 4     | 5     |
Input Speed     | 600     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1670 (242)     | 0 (0)     | 1080 (157)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1285 ±150 (186 ±22)     | 1795 ±150 (260 ±22)     | 3725 ±50 (540 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 14420 (2091)     | 21340 (3095)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 96 (25.4)     | 160 ±3 (42.3 ±0.8)     | 156 ±3 (41.2 ±0.8)     | 103.5 ±5 (27.3 ±1.3)     | 58 ±5 (15.3 ±1.3)     | 158 ±6 (41.7 ±1.6)     | 107.5 ±6 (28.4 ±1.6)     | 20 ±3 (5.3 ±0.8)     | 144 ±3 (38 ±0.8)     | 135.9 ±3 (35.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 18 ±3 (4.8 ±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 15 (4.0)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 19.0 (5.0)     | 17.1 (4.5)     | |||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 204-2697     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 216-0031     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 216-0032     |
Canceled and Replaced by 247-8975     |
Part Number     | 216-0038 (1)     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Solenoid Amperage (mA)     | -     | 650     | -     | -     | -     | 650     | ||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 17.5 (4.6)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
( 1 ) | Note: This pump is equipped with a solenoid to control powershift. |
Part Number     | 216-0039     |
Canceled and Replaced by 242-6779     |
Part Number     | 222-0103     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1270 (184)     | 0 (0)     | 961 (139)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1780 ±150 (258 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 13440 (1949)     | 20100 (2915)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 26580 (3855)     | ||
Discharge Flow lpm (gpm)     | 61 (16.2)     | 92.5 ±3 (24.4 ±0.8)     | 89 ±3 (23.5 ±0.8)     | 55 ±3 (14.5 ±0.8)     | 28 ±3 (7.4 ±0.8)     | 90.5±6 (23.9 ±1.6)     | 55 ±3 (14.5 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 85.5 ±3 (22.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 13 (3.4)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 222-0107     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1270 (184)     | 0 (0)     | 961 (139)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1780 ±150 (258 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 13440 (1949)     | 20100 (2915)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 26580 (3855)     | ||
Discharge Flow lpm (gpm)     | 61 (16.2)     | 92.5 ±3 (24.4 ±0.8)     | 89 ±3 (23.5 ±0.8)     | 55 ±3 (14.5 ±0.8)     | 28 ±3 (7.4 ±0.8)     | 90.5±6 (23.9 ±1.6)     | 55 ±3 (14.5 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 85.5 ±3 (22.6 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 13 (3.4)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 222-0108     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1320 (191)     | 0 (0)     | 440 (64)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1620 ±150 (199 ±22)     | 2030 ±150 (294 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18300 (2654)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 77.5±3 (20.5 ±0.8)     | 55±3 (14.5 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 69±3 (18.2 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 3920 (568)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 6.42 (1.7)     | 9.6 (2.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 222-0109     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     | 1000     |
Power Shift Pressure kPa (psi)     | -     | 1270 (184)     | 0 (0)     | 1000 (145)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1320 ±150 (191 ±22)     | 1740 ±150 (252 ±22)     | 3380 ±50 (490 ±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 15800 (2292)     | 22600 (3278)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 30700 (4452)     | ||
Discharge Flow lpm (gpm)     | 64 (17)     | 107 +0/-6 (28.3 +0/ -1.6)     | 104 ±3 (27.5 ±0.8)     | 67.5 ±5 (17.8 ±1.3)     | 43.5±5 (11.5 ±1.3)     | 105.5 ±6 (27.8 ±1.6)     | 69 ±6 (18.2 ±1.6)     | 16.5±3 (4.4 ±0.8)     | 107 +0/-6 (28.3 +0/ -1.6)     | 101 ±3 (26.7 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 16.5±3 (4.4±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 8 (2.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 19.0 (5.0)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 222-0110     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1120 (162)     | 0 (0)     | 980 (142)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1460 ±150 (212 ±22)     | 1740 ±150 (252 ±22)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 18700 (2712)     | 25100 (3640)     | 34300 (4975)     | 13700 (1987)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 80 (21.1)     | 120 ±3 (31.7 ±0.8)     | 115.5 ±3 (30.5 ±0.8)     | 81.5±3 (21.5 ±0.8)     | 58.5 ±3 (15.4 ±0.8)     | 118 ±6 (31.2 ±1.6)     | 86.5±3 (22.8 ±0.8)     | 15 ±3 (4.0 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 111 ±3 (29.3 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 12 (3.2)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 242-6779     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 17.5 (4.6)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 247-8975     |
Canceled and Replaced by 283-5975     |
Part Number     | 250-2564     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 283-5973     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 283-5975     |
Canceled and Replaced by 311-9542     |
Part Number     | 311-9541     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 900     |
Power Shift Pressure kPa (psi)     | -     | 1275 (185)     | 0 (0)     | 1275 (185)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1470 ±150 (213 ±22)     | 1800 (261)     | 3580 ±50 (519±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 17000 (2466)     | 25000 (3626)     | 34300 (4975)     | 7000 (1015)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 93 (24.6)     | 140 ±3 (37 ±0.8)     | 134 ±3 (35.4 ±0.8)     | 92.5 ±3 (24.4 ±0.8)     | 61.5 ±3 (16.2 ±0.8)     | 137 ±6 (36.2 ±1.6)     | 105 (27.7)     | 15 ±3 (4.0 ±0.8)     | 140 ±3 (37 ±0.8)     | 128.5 ±3 (33.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 3630 (527)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 15±3 (4.0±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 11 (3)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | ||||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Part Number     | 311-9542     | |||||||||
Step Number     | 1     | 2a     | 2b     | 2c     | 2d     | 3a     | 3b     | 3c     | 4     | 5     |
Input Speed     | 600     | 900     | 900     | 900     | 900     | 900     | 900     | 900     | 800     | 800     |
Power Shift Pressure kPa (psi)     | -     | 2370 (343)     | 0 (0)     | 940 (136)     | ||||||
Negative Flow Control Pressure kPa (psi)     | -     | 0 (0)     | 1180 ±150 (171 ±22)     | -     | 3630 ±50 (526±7)     | 0 (0)     | ||||
Discharge Pressure kPa (psi)     | -     | 0 (0)     | 7100 (1030)     | 14800 (2147)     | 34300 (4975)     | 6860 (995)     | 0 (0)     | 34300 (4975)     | ||
Discharge Flow lpm (gpm)     | 119 (31.6)     | 179.5 ±3 (47.4 ±0.8)     | 177.5 ±3 (46.9 ±0.8)     | 120 ±3 (31.7 ±0.8)     | 43 ±3 (11.4 ±0.8)     | 177.5 ±6 (46.9 ±1.6)     | -     | 20 ±3 (5.3 ±0.8)     | 144 ±3 (38 ±0.8)     | 136 ±3 (35.9 ±0.8)     |
Standby Negative Flow Control Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Pressure kPa (psi)     |     | 4900 (710)     | ||||||||
Standby Discharge Flow lpm (gpm)     |     | 17.8 ±3 (4.7 ±0.8)     | ||||||||
Max. Internal Leakage lpm (gpm)     |     | 15.5 (4.1)     | ||||||||
Minimum Pilot Pump Discharge lpm (gpm)     | 11.4 (3.0)     | 17.1 (4.5)     | 15.2 (4.0)     | |||||||
Pilot Pump Discharge Pressure kPa (psi)     | 3920 (570)     |
Test Bench Tooling
Part Number     | Mounting Flange     | Drive Adapter     | Suction Adapter     | Split Flange     | Flange Adapter     | Power Shift Port     | Neg. Flow Port     | Charge Pump Discharge     |
7I-7590     | 4C-4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
7Y-4002     | 4C-4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
7Y-4009     | 9U-5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
087- 4828     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
114- 0602     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
114- 0603     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
114- 0604     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
114- 0605     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
114- 0662     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
123- 1993     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
123- 2231     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
123- 2233     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
123- 2235     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
128- 9062     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
153- 9184     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
153- 9185     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
159- 7779     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
162- 0917     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
165- 9322     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
171- 3239     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
185- 0220     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
194- 8383     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
200- 3550     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
204- 2697     | 9U- 5750     | 9U- 7519     | 457-2323     | 1P-5657     | 9U-7440     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
216- 0031     | 9U- 5750     | 9U- 7519     | 457-2323     | 1P-5657     | 9U-7440     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
216- 0032     | Canceled, replaced by 247-8975     | |||||||
216- 0038     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
216- 0039     | Canceled, replaced by 242-6779     | |||||||
222- 0103     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
222- 0107     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
222- 0108     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
222- 0109     | 4C- 4622     | 9U- 5745     | 1U- 9868     | 124-4288     | 9U- 7439     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
242-6779     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |
247-8975     | Canceled, replaced by 283-5975     | |||||||
250-2564     | 9U- 5750     | 9U- 7519     | 457-2323     | 1P-5657     | 9U-7440     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
283-5973     | 9U- 5750     | 9U- 7519     | 457-2323     | 1P-5657     | 9U-7440     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
283-5975     | Canceled, replaced by 311-9542     | |||||||
311-9541     | 9U- 5750     | 9U- 7519     | 457-2323     | 1P-5657     | 9U-7440     | 3/8 STOR     | 3/8 STOR     | 1/2 STOR     |
311-9542     | 9U- 5750     | 9U- 7519     | 457-2323     | 2T-3001     | 9U- 7440     | 9/16 STOR     | 9/16 STOR     | 3/4 STOR     |