CID 0271 FMI 05 Alarm (Action) Current Below Normal - Test

Usage:

3516B 1NW



Illustration 1g00573861

Schematic For Action Alarm.

(1) Locomotive - 410-WH: Marine Engines and Generator Engines - 025-GN.

This diagnostic code is recorded when the Main Display Module reads the current of the circuit for the Action Alarm as below normal current. Also, this diagnostic code is recorded when the Main Display Module reads an open circuit with the Action Alarm. As a result of this action, the Action Alarm does not sound when the Action Alarm should sound.

  1. Check The Alarm.

    1. Disconnect the engine harness from the Action Alarm.

    1. Place a jumper wire across the two leads of the Action Alarm of the engine harness.

      Expected Result: The FMI 05 diagnostic code should remain active.

      Results:

      • OK - The FMI 05 diagnostic code is still active. The Action Alarm is not causing the problem. Measure the resistance across the terminals of the Action Alarm. The resistance should be 200 ± 100 ohms. If the resistance of the Action Alarm is good, but the alarm does not sound, proceed to Step 2.

      • Not OK - If the FMI 05 diagnostic code is not active, the Action Alarm has a problem. Measure the resistance across the terminals of the Action Alarm. The resistance should be 200 ± 100 ohms. If the resistance of the Action Alarm is good, but the alarm does not sound, proceed to Step 2. If the resistance of the Action Alarm is not good, then replace the Action Alarm. Proceed to Step 2.

  1. Check The Harness.

    1. Turn the "ECS" switch to the OFF/RESET position.

    1. Remove the jumper wire from the harness leads of the Action Alarm.

    1. Reconnect the harness leads to the Action Alarm.

    1. Disconnect the engine harness from the Action Alarm.

    1. At the engine harness connector for the Main Display Module, measure the resistance from contact 4 to contact 2. Contact 2 is the ground.

      Expected Result: The resistance should be less than 300 ohms.

      Results:

      • OK - The resistance is less than 300 ohms. The harness resistance is correct. Proceed to Step 4.

      • Not OK - The resistance is greater than 300 ohms. The harness circuit is open. Proceed to Step 3.

  1. Check The Harness.

    Disconnect the engine harness from the Action Alarm. Check for an open circuit between the Main Display Module (contact 4) and the lead of the Action Alarm (terminal 1). Also, check for an open circuit between the lead of the Action Alarm (terminal 2) and ground. If an open circuit is found, repair the harness or replace the harness.

  1. Check The Main Display Module.

    1. Turn the "ECS" switch to the OFF/RESET position.

    1. Turn the "ECS" switch to the OFF/RESET position.

    1. Reconnect the engine harness connector to the Main Display Module.

    1. Reconnect the engine harness to the Action Alarm.

    1. Turn the "ECS" switch to the COOLDOWN/STOP position.

      Expected Result: The FMI 05 diagnostic code should not be active.

      Results:

      • OK - The FMI 05 diagnostic code is not active. The Main Display Module is not causing the problem. The problem is intermittent. The probable cause is a poor electrical connection at the harness connectors or a damaged harness. Check the harness for damage and clean the connectors when cleaning is required.

      • Not OK - The FMI 05 diagnostic code is still active. The Main Display Module has a problem. Replace the Main Display Module. For more information, see Testing And Adjusting, "Module - Replace".

Caterpillar Information System:

C-10 and C-12 Industrial Engines Engine Oil Cooler
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0271 FMI 03 Alarm (Action) Voltage Above Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0263 FMI 04 Sensor Power Supply Voltage Below Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0263 FMI 03 Sensor Power Supply Voltage Above Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0248 FMI 02 Cat Data Link Incorrect - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0177 FMI 08 Temperature Sensor (Transmission Oil) Abnormal Signal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0175 FMI 04 Temperature Sender (Engine Oil) Voltage Below Normal - Test
3406C (PEEC III) Truck Engines Compression Brake
3412E and C30 Marine Engines Air Inlet And Exhaust System
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0172 FMI 04 Temperature Sender (Inlet Air) Voltage Below Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0127 FMI 08 Pressure Sensor (Transmission Oil) Abnormal Signal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0096 FMI 03 Level Switch (Fuel) Voltage Above Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0271 FMI 06 Alarm (Action) Current Above Normal - Test
3606 and 3608 Engines Vibration Damper - Dual
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0819 FMI 02 Display Data Link Incorrect - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0821 FMI 03 Display Power Supply Voltage Above Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System CID 0821 FMI 04 Display Power Supply Voltage Below Normal - Test
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Alert Indicator - Troubleshoot
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System LH/RH Switch - Troubleshoot
3508, 3508B, 3508C, 3512, 3512B, 3512C, 3516, 3516B and 3516C Engines Caterpillar Monitoring System Scroll Switch - Troubleshoot
G3408 and G3412 Engines Engine Oil Filter Base
3176C and 3196 Marine Engines Engine Oil Cooler
3606 and 3608 Engines Vibration Damper - Single
G3408 and G3412 Engines Crankshaft
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.