This service program code shows the event list in an abbreviated form. The entries of the event list are displayed: "last event in - first event out". The "first event out" represents the INACTIVE time of the event. Some events may appear out of order based on the start times of the events. Use the "BACKWARD" and "FORWARD" arrow keys to scroll through the list. The message "END OF LIST" is shown when the oldest event in the list is reached.
- This list contains only inactive EVENTS. An inactive event has a defined "start time and end time". Active events will not appear in this list.
- While the "ELIST" is displayed, any new event that becomes inactive will be added to the beginning of the "ELIST". The new entry to the "ELIST" may be viewed by pressing the backward arrow key in order to move to the beginning of the new "ELIST".
Data (Machine) Events
The following information is shown in the VIMS message area for each data (machine) event in the event list:
- The name of the parameter
- The status of the parameter ("LO", "HI", etc.)
- Service meter reading at the start of the event.
- The event duration
- The warning category
An example of a machine event with sensor information is shown here:
Illustration 1 | g00485804 |
An example of a data event with switch information is shown here:
Illustration 2 | g00569208 |
245.2 is the service meter reading at the start of the event. 000:04:13 is the duration of the event in HHH:MM:SS format. The 2 that follows the "event duration" represents the warning category 2.
Press the "F1" key while you view a data event. This function will replace the information that is shown on the second line of the message area. The new information that is shown contains information about the maximum values that were measured for the parameter such as "2266 RPM" or "LO (switch)". Pressing the "OK" key puts the message center back into the previous mode. See the Systems Operation, "Keypad" topic for additional information. Pressing the "OK" key puts the message center back into the original mode.
Maintenance/Diagnostic (System) Events
The following information is shown in the VIMS message area for each system event in the event list.
- The name of the parameter
- The status of the parameter (ERR, etc.)
- Service meter reading at the start of the event.
- The event duration
- The event category
An example of a maintenance type of service event with information about the sensor:
Illustration 3 | g00551525 |
245.2 is the service meter reading at the start of the event. 000:04:13 is the duration of the event in HHH:MM:SS format. The "2" is the warning category.
When you view a diagnostic event, press the "F1" key in order to replace the information that is shown on the second line of the message area. The information in the message area is replaced with the "MID-CID-FMI". The message center can be returned to the original mode by pressing the "OK" key. The FORWARD and BACKWARD arrow keys are used to scroll through the event list.
See the Systems Operation, "Keypad" topic for additional information.