3145, 3150 & 3160 ELECTRIC SET ENGINES Caterpillar


Oil Pressure Switch

Usage:

Rating when used with alarm or switch:

24 Volts DC ... 6 A

12 Volts DC ... 8 A

6 Volts DC ... 15 A

2N2916

With an increase in pressure, switch closes at ... 30 psi(2.1 kg/cm2)

With a decrease in pressure, switch opens at ... 25 to 27 psi(1.7 to 1.9 kg/cm2)

2L3402

With an increase in pressure, switch closes at ... 3 to 4 psi(0.2 to 0.3 kg/cm2)

3N614

With an increase in pressure, normally closed points open at ... 30 psi(2.11 kg/cm2)

With an increase in pressure, normally opened points close at ... 35 psi(2.46 kg/cm2)