Usage:
Rating when used with alarm or switch:
24 Volts DC ... 6 A
12 Volts DC ... 8 A
6 Volts DC ... 15 A
2N2916
With an increase in pressure, switch closes at ... 30 psi(2,1 kg/cm2)
With a decrease in pressure, switch opens at ... 25 to 27 psi(1,7 to 1,9 kg/cm2)
2L3402
With an increase in pressure, switch closes at ... 3 to 4 psi(0,2 to 0,3 kg/cm2)
2N2240
With a decrease in pressure, switch closes at ... 15 psi(1,1 kg/cm2)
2N7744
Rating when used with alarm or switch:
32 Volts DC ... 2.5 A
With an increase in pressure, switch closes at ... 12 psi(0,8 kg/cm2)
With a decrease in pressure, switch opens at ... 5 psi(0,4 kg/cm2)
3N614
With an increase in pressure, normally closed points open at ... 30 psi(2,11 kg/cm2)
With an increase in pressure, normally opened points close at ... 35 psi(2,46 kg/cm2)