Usage:
Start By:
a. remove water separator
Fluid Spillage Containment
Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the machine. Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Refer to "Tools And Shop Products Guide", NENG2500 for tools and supplies suitable to collect and contain fluids in Caterpillar machines. Dispose fluids according to local regulations and mandates.
1. Remove valve (5) and washer (4).
2. Remove nut (3) and filter element (2) from filter base (1).
3. Remove nut (11), cap (10), seal (9), and regulator (8) from filter base (1).
4. Remove plugs (12) and washers (13) from filter base (1).
5. Remove plug (7) and O-ring seal (6) from filter base (1).
NOTE: Assembly the water separator in reverse order.
End By:
install water separator