Illustration 1 | g01677616 |
When the electric starting motor is viewed from the pinion end, the motor rotates in the following direction. ... Clockwise
No load conditions at 25 °C (77 °F)
- Minimum speed ... 5500 rpm
- Maximum current draw ... 140 Amp
- Voltage ... 24 V
- Maximum current draw ... 140 Amp
(B) The clearance between the pinion and the housing ... 8.3 to 9.9 mm (0.33 to 0.39 inch)
(1) Final installation torque for the ground terminal nut ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
Note: A maximum of three cable terminals or wire terminals may be used with the nut. A maximum of two of the terminals may be equal to or greater than 0 AWG.
(2) Final installation torque for the battery terminal nut ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
(3) Final installation torque for the ground terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(4) Final installation torque for the switch terminal nut ... 2.25 ± 0.25 N·m (20 ± 2 lb in)
(5) Final installation torque for the motor frame terminal nut ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
(6) Final installation torque for the motor terminal nut ... 30.5 ± 3.5 N·m (270 ± 30 lb in)
Solenoid assembly
Current consumption at 24 V and 25 °C (77 °F)
- Pull-in windings ... 51 Amp
- Hold-in windings ... 7 Amp