- Excavator
- 312E (S/N: GAC1-UP)
- 314F (S/N: RAF1-UP)
- 318C (S/N: FAA1-UP; GPA1-UP; BTG1-UP; DAH1-UP; MDY1-UP)
- 319C (S/N: KGL1-UP)
- 320C (S/N: BEA1-UP; EGA1-UP; GLA1-UP; ANB1-UP; BGB1-UP; MAB1-UP; PAB1-UP; AMC1-UP; BDC1-UP; HBC1-UP; MAC1-UP; PAC1-UP; GAD1-UP; BDE1-UP; DBG1-UP; JTG1-UP; SAH1-UP; AXK1-UP; BKK1-UP; BBL1-UP; EGL1-UP; JPL1-UP; CLM1-UP; BCN1-UP; SBN1-UP; BER1-UP; BPR1-UP; TBR1-UP; RAW1-UP; BRX1-UP; BMZ1-UP; CLZ1-UP)
- 320D (S/N: JZA1-UP; ZGB1-UP; HJC1-UP; JPD1-UP; MZD1-UP; DHE1-UP; MDE1-UP; TAE1-UP; A6F1-UP; A8F1-UP; A9F1-UP; BZF1-UP; KGF1-UP; KTF1-UP; KZF1-UP; MGG1-UP; MCH1-UP; TDH1-UP; DHK1-UP; FXK1-UP; XCK1-UP; FAL1-UP; GKL1-UP; KLM1-UP; PCM1-UP; KHN1-UP; SPN1-UP; WBN1-UP; BZP1-UP; GDP1-UP; YDS1-UP; EJT1-UP; SRT1-UP; GMX1-UP; PCX1-UP; PHX1-UP; CXY1-UP; EBY1-UP; JFZ1-UP; JGZ1-UP)
- 320D2 (S/N: GBA1-UP; LMA1-UP; YEA1-UP; XBB1-UP; ZBD1-UP; PFE1-UP; TMF1-UP; DGH1-UP; NBH1-UP; ZBH1-UP; YBJ1-UP; FKK1-UP; XAK1-UP; EAL1-UP; DFM1-UP; HDM1-UP; JFM1-UP; DNP1-UP; KHR1-UP; ZCS1-UP; NBT1-UP)
- 320E (S/N: REE1-UP; SXE1-UP; DFG1-UP; TNJ1-UP; LAK1-UP; WBK1-UP; PNL1-UP; LHN1-UP; AWS1-UP; KLT1-UP; MEW1-UP; SHX1-UP; TEX1-UP; TFX1-UP; NAZ1-UP)
- 320F (S/N: ZRC1-UP; NHD1-UP; WJJ1-UP; YBM1-UP; TET1-UP; REW1-UP; SFX1-UP)
- 321C (S/N: MCF1-UP; KCR1-UP)
- 321D (S/N: TXA1-UP; PBD1-UP; MPG1-UP; NAS1-UP; MDT1-UP; KBZ1-UP)
- 322C (S/N: DAA1-UP; FED1-UP; BPH1-UP; M2H1-UP; BKJ1-UP; BFK1-UP; HEK1-UP; BYL1-UP; BKM1-UP; CAM1-UP; BLP1-UP; BGR1-UP; C3R1-UP; EMR1-UP; LAR1-UP; MAR1-UP; CBY1-UP)
- 323D (S/N: RAC1-UP; SDC1-UP; WGC1-UP; CYD1-UP; SED1-UP; YSD1-UP; NDE1-UP; PBE1-UP; WNE1-UP; GTF1-UP; NZF1-UP; ZMF1-UP; CWG1-UP; JLG1-UP; LFL1-UP; BYM1-UP; PBM1-UP; NES1-UP; DKW1-UP)
- 323D2 (S/N: KCE1-UP; JEG1-UP; XBK1-UP; HCM1-UP; GYN1-UP; PJP1-UP; YCR1-UP; JEX1-UP; KBX1-UP)
- 323E (S/N: RAP1-UP; YRP1-UP; TDW1-UP)
- 323F (S/N: FA21-UP; PLB1-UP; YEC1-UP; XCF1-UP; YEJ1-UP; LMK1-UP; MDL1-UP)
- 324D (S/N: LAB1-UP; EJC1-UP; MND1-UP; T2D1-UP; JJG1-UP; TRH1-UP; BTK1-UP; GPK1-UP; SYM1-UP; TSN1-UP; DFP1-UP; JZR1-UP; JAT1-UP; PYT1-UP; CJX1-UP)
- 324E (S/N: KTE1-UP; TLF1-UP; LDG1-UP; PNW1-UP; JCZ1-UP)
- 325C (S/N: CRB1-UP; JLC1-UP; S2C1-UP; BTD1-UP; JLD1-UP; BFE1-UP; DTF1-UP; AMH1-UP; CSJ1-UP; M2K1-UP; G1L1-UP; BMM1-UP; S3M1-UP; Y4P1-UP; BKW1-UP)
- 325D (S/N: GPB1-UP; NAC1-UP; PKE1-UP; KDG1-UP; C4H1-UP; C7K1-UP; ERK1-UP; RJK1-UP; LAL1-UP; MCL1-UP; PAL1-UP; C9M1-UP; AZP1-UP; A3R1-UP; GBR1-UP; SCR1-UP; T2S1-UP; CYW1-UP)
- 325F (S/N: XAA1-UP; YCA1-UP)
- 326D (S/N: PJM1-UP)
- 326D2 (S/N: JFL1-UP; MGW1-UP; NBX1-UP; KGY1-UP)
- 326F (S/N: TPG1-UP; HCJ1-UP; SGK1-UP; XFK1-UP; WGL1-UP; TMR1-UP)
- 328D (S/N: SWF1-UP; GTN1-UP; MKR1-UP; RMX1-UP)
- 329D (S/N: MNB1-UP; XDB1-UP; BFC1-UP; CZF1-UP; JHJ1-UP; RSK1-UP; WDK1-UP; TZL1-UP; TPM1-UP; WLT1-UP; YFW1-UP; SCY1-UP; TAY1-UP; DTZ1-UP)
- 329D2 (S/N: RGA1-UP; KJB1-UP; SHJ1-UP; TMJ1-UP; WDT1-UP)
- 329E (S/N: RLD1-UP; ZCD1-UP; WJK1-UP; TST1-UP; PLW1-UP; RDX1-UP; PTY1-UP)
- 329F (S/N: YHA1-UP; GKK1-UP; ERL1-UP; RCN1-UP; ZNN1-UP)
- 330D2 (S/N: ZBF1-UP)
- 330F (S/N: WBA1-UP; LBN1-UP)
- 335F (S/N: KNE1-UP; FEP1-UP; JJR1-UP)
- 314F (S/N: RAF1-UP)
- Forest Machine
- 320D FM (S/N: GKS1-UP; BWW1-UP; EAX1-UP; CYZ1-UP)
- 320D2 FM (S/N: BW21-UP; CY21-UP)
- 324D FM (S/N: JGK1-UP; JKR1-UP; JLS1-UP)
- 325D FM (S/N: C8L1-UP)
- 538 (S/N: KBJ1-UP; GMY1-UP)
- 548 (S/N: WRA1-UP; SFZ1-UP)
- 558 (S/N: F5G1-UP; F5L1-UP; RHS1-UP)
- 320D2 FM (S/N: BW21-UP; CY21-UP)
- Material Handler
- M325D L MH (S/N: ETE1-UP)
- M325D MH (S/N: GE81-UP; EDF1-UP; KAY1-UP)
- Mobile Hydraulic Power Unit
- 323D MHPU (S/N: DCJ1-UP; L5Z1-UP)
- 324D MHPU (S/N: KJR1-UP)
- 325C MHPU (S/N: MSG1-UP)
- 325D MHPU (S/N: C3N1-UP; H3N1-UP)
- 329D MHPU (S/N: J9D1-UP; L5G1-UP; L5H1-UP)
- 329E MHPU (S/N: K2L1-UP)
- 324D MHPU (S/N: KJR1-UP)
- Wheeled Excavator
- M325C (S/N: XJA1-UP; PAN1-UP)
Introduction
Revision | Summary of Changes in REHS3650 |
21 | Added new Excavator serial number prefix FEB to document. |
20 | Added new Excavator serial number prefixes F5G, SFZ, and WRA to document. |
19 | Added new Excavator serial number prefix FA2 to document. |
18 | Added new Excavator serial number prefixes YEC and ZBF to document. |
Added Blank Specifications Table to document. |
© 2017 Caterpillar All Rights Reserved. This guideline is for the use of Cat dealers only. Unauthorized use of this document or the proprietary processes therein without permission may be violation of intellectual property law. Information contained in this document is considered Caterpillar: Confidential Yellow.
This Special Instruction includes test procedures for piston pumps. This Special Instruction also provides specifications. The technician should have a good understanding of hydraulic piston pumps. The technician should be educated in the operation of the hydraulic test bench. The test benches in this document are available through the Caterpillar Service Tool Division. Gather all necessary tooling before you need to hook up the pump. Some of the required tooling appears in a table at the end of this document. There are many possible variations of tooling that could be used. Not every possible variation can be listed.
For technical questions when using this document, work with your Dealer Technical Communicator (TC).
To report suspected errors, inaccuracies, or suggestions regarding the document, submit a form for feedback in the Service Information System (SIS Web) interface.
Canceled Part Numbers and Replaced Part Numbers
This document may not include all Canceled part numbers and replaced part numbers. Use NPR on SIS for information about Canceled part numbers and replaced part numbers. NPR will provide the current part numbers for replaced parts.
Safety
Illustration 1 | g02139237 |
Personal injury or death can result from improperly checking for a leak. Always use a board or cardboard when checking for a leak. Escaping air or fluid under pressure, even a pin-hole size leak, can penetrate body tissue causing serious injury, and possible death. If fluid is injected into your skin, it must be treated immediately by a doctor familiar with this type of injury. |
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin. |
Pump test pressures in this guideline may exceed the normal operating range of the hydraulic test hoses utilized when connecting the tested pump to the test bench. However, the order of magnitude of these pressures is significantly below the burst strength of the Caterpillar "XT6" product. High pressure oil can escape through improperly assembled hoses and fittings. High pressure oil can also escape through poorly maintained hoses and fittings. High pressure oil may also leak through hose that has become damaged over the life of the hose due to the pressure levels that occur during test bench operation. Personal injury or death can result from improper hose & fitting inspection or improper hose replacement procedures. Escaping fluid under pressure can penetrate body tissue causing serious injury, and possible death. Thoroughly inspect all testing hoses, fittings, and quick disconnects prior to any testing operation. Check the assembly date tag or hose assembly log date for a hose life indicator. Replace all Test Bench hoses at a minimum of every 2 years or earlier if the hose or fittings appear to be damaged. |
Summary
This procedure is specific to the type of pump and the type of control. This procedure should be used with the Test Specifications and Test Bench Tooling at the end of this Special Instruction.
Note: The paper copy of this Special Instruction may not be the newest version. Go to the Service Information System (SIS) in order to view the latest version.
References
References | |
---|---|
Media Number | Title |
REHS1761 | "Required Tooling for Bench Testing Hydraulic Components" |
SEBF8810 | "Hydraulic Pump, Motor, and Cylinder Bench Test Procedure Reference Manual" |
SEHS8892 | "Operating Instructions for Caterpillar 1U-9400 Series Hydraulic Test Center" |
NEHS0563 | "Tool Operating Manual for 9U-5000 Series Hydraulic Test Bench" |
Connections for the Caterpillar Hydraulic Test Center
Illustration 2 | g01063311 |
Connections for the Test Center (1) Flow control for discharge (2) "F3" flow meter inlet (3) "F4" flow meter inlet (4) Oil supply from the auxiliary pump (5) "F3" outlet for the flow meter with flow limiter (6) Oil supply (7) Load sensing pressure (8) Signal pressure (9) "F4" outlet for the flow meter (10) Return to tank (11) Connections for case drain (12) Oil supply |
Illustration 3 | g01063312 |
Control and Gauges for the Test Center (13) Meter for speed and torque (14) Gauge for signal pressure (15) Control for signal pressure (16) Pressure gauge for auxiliary pump (17) Auxiliary pump flow (18) "F3" discharge pressure gauge (19) "F3" discharge flow (20) "F4" discharge pressure gauge (21) "F4" discharge flow (22) Auxiliary pump flow control (23) "F3" margin pressure (24) "F3" Load control for discharge pressure (25) "F4" Load control for discharge pressure |
Connections for the Caterpillar Hydraulic Test Bench
Illustration 4 | g01063314 |
Connections for the Test Bench (26) "Flow meter 1" loop and "Flow meter 2" loop (27) Oil Supply |
Illustration 5 | g01063315 |
Connections for the Test Bench (28) "Flow meter 2" loop (29) "Flow meter 1" loop (30) "Flow meter 2" outlet (31) Signal pressure line (32) "Flow meter 2" inlet (33) Auxiliary pump oil supply (34) "Flow meter 1" inlet (35) "Flow meter 1" inlet |
Illustration 6 | g01063316 |
Control and Gauges for the Test Bench (36) Auxiliary pump pressure (37) Signal pressure (38) Control for signal pressure (39) "Flow meter 1" discharge pressure (40) Control for auxiliary pump pressure (41) "Flow meter 2" discharge pressure (42) Auxiliary pump flow control (43) "Flow meter 2" discharge flow (44) Discharge flow for auxiliary pump (45) "Flow meter 1" discharge flow (46) "Flow meter 1" load control (47) Speed and direction control (48) "Flow meter 2" load control |
Port Locations
Illustration 7 | g01115839 |
Typical port locations and adjustments. |
Illustration 8 | g01414997 |
Typical port locations and adjustments. Aux pump and OCS pump may or may not be present. (49) Ps1 Pressure Port for Power Shift (50) A1 Discharge Port (51) A2 Discharge Port (52) A5 Discharge Port for the Aux Pump (53) Pi Pressure Port for Power Shift (54) Pn1 Pressure Port for Negative Flow Control (55a) Adjustment Screw for Torque Control on Drive Pump (55b) Adjustment Screw for Torque Control on Driven Pump (56) S5 Suction Port for the Aux Pump (57) S1 Suction Port (58a) Adjustment Screw for Maximum Angle on Drive Pump (58b) Adjustment Screw for Maximum Angle on Driven Pump (59) Ps2 Pressure Port for Power Shift (60) Pn2 Pressure Port for Negative Flow Control (61) Dr1 Case Drain Port (62) Electrical Connector for Solenoid (63) Aux Pump (Aux pump may not be present) (64a) A3 Discharge Port for the Pilot Pump (64b) A4 Discharge Port for the OCS Pump (65) Pilot and OCS Pump (OCS pump may not be present) (66a) S4 Suction Port for the OCS Pump (66b) S3 Suction Port for the Pilot Pump (67a) Adjustment screw for Minimum Angle on Driven Pump (67b) Adjustment screw for Minimum Angle on Drive Pump (68a) Adjustment location for Negative Flow Control on Driven Pump (68b) Adjustment location for Negative Flow Control on Drive Pump |
Pump Setup
Illustration 9 | g03425520 |
Hydraulic schematic The aux pump, OCS pump, and the associated ports may or may not be present depending on part number. |
- Mount the pump with the suction port (57) downward. Use an adapter to connect the pump to the test bench oil supply.
- Connect suction port (57) to the test bench oil supply. Connect the suction port for the pilot pump (66b) to the test bench oil supply. Connect the discharge port for pilot pump (64a) according to Illustration 9. The use of a 120-9181 Valve Body, a 4C-4014 Relief Valve, a 8T-0856 Pressure Gauge,, and a 8T-0454 Flow Meter will be required to perform the test procedure.
Connect the suction port for the OCS pump (if equipped) (66a) to the test bench oil supply. Connect the discharge port for the OCS pump (64b) to the test bench reservoir.
Connect the suction port for the aux pump (if equipped) (56) to the test bench oil supply. Connect the discharge port for the aux pump (52) to the test bench reservoir.
- Connect discharge ports (50) and (51) to the flow meter inlets on the test bench. Connect flow meter outlets from the test bench back to tank.
- Fill the pump case with oil. Pour oil directly into case drain port (61) until the case is completelyfull.
- Purge all air from the suction line. Loosen the suction hose at the pump until oil leaks from the connection. Tighten the suction hose.
- Install the flow meter to case drain port (61).
- Connect one end of the hose to the outlet of the flow meter and route the other end of the hose back to the tank.
- Connect a power supply to the electrical connector for solenoid (62). The power supply should be capable of delivering 0 mA to 1.5 A with an infinite setting in that range.
Note: NOTE: When performing Step 3 of the Test Procedure, be sure to plumb the pump correctly by connecting PS1 to PS2 using a pressure gauge.
If a signal pressure greater than the test bench's capability is required, the use of a pressure reducing valve is necessary. The pressure reducing valve will use the pump's discharge to produce a signal less than the discharge pressure for use as a control pressure.
Connect one flow meter outlet from the test bench to port for inlet pressure (74). Connect port for outlet pressure (72) to the control port in need of signal pressure. Connect outlet port to tank (70) to bench reservoir.
Use the gauge port for outlet pressure (73) to adjust the outlet signal pressure using the adjustment screw for outlet pressure (69). Adjust the outlet pressure to the value needed for the control application.
Illustration 10 | g03425385 |
|
Illustration 11 | g03425386 |
|
Illustration 12 | g03425387 |
(69) Adjustment screw for the outlet pressure (70) Outlet port to tank (71) Gauge port for the inlet pressure (72) Port for the outlet pressure (73) Gauge port for the outlet pressure (74) Port for the inlet pressure |
Test Procedure
The hydraulic oil in the test bench should meet a contamination rating of ISO 16/13 or better. The oil in the test bench should be one of the following.
- SAE 10W at
50 °C (122 °F) or - Mobil DTE-11 at
46 °C (115 °F)
Illustration 13 | g01257351 |
Torque control curve for steps 3a and 4a. (P) Discharge Pressure (Q) Discharge Flow |
Illustration 14 | g01257709 |
Negative flow characteristics for steps 5a and 5b (Q) Discharge flow (R) Negative flow control pressure |
- Start rotating the pump according to Step 1 of the Test Specifications. Listen for abnormal noise. Verify that all connections are not leaking. Check for leaks around shaft seals and control valves.
Run the pump for at least 5 minutes in order to raise the temperature of the oil and purge the system of air.
- Slowly increase the pump rotation and the discharge pressure according to Step 2 of the Test Specifications. If equipped, verify the flow out of the pilot and OCS pump (65). If equipped, verify the flow out of the aux pump (52). Adjust 4C-4014 Relief Valve to the pilot pump discharge pressure in step 2 of the Test Specifications. If the main pump's maximum flow is not within specifications, adjust the adjustment screws for maximum angle (58a) and (58b). Loosen the locknut and turn the adjustment screws for maximum angle (58a) and (58b) counter-clockwise in order to increase the flow until the actual discharge flow is within specifications. Loosen the locknut and turn the adjustment screws for the maximum angle (58a) and (58b) clockwise in order to decrease the flow until the actual discharge flow is within specifications.
Show/hide table
Illustration 15 g03426023 Hydraulic schematic - The following step will verify the destroke point and the first stage of the torque control. Before the following step can be performed, refer to Illustration 15 for the plumbing arrangement.
- Rotate the pump. Adjust the current input according to Step 3a of the Test Specifications. Read the power shift pressure at 8T-0856 Pressure Gauge. If the pressure is not correct, adjust the current to the solenoid until the pressure is correct. Load both pumps' discharge ports to the values in Step 3a of the Test Specifications. Verify that the values for the pump discharge ports are equal. Adjust the first stage of the torque control if the flow rates are not within specifications. Loosen the large locknut on the adjustment screws for torque control (55a) and (55b) in order to adjust the torque control. Turn the sleeve clockwise in order to increase flow. Turn the sleeve counterclockwise in order to decrease flow. Adjust the sleeve until flow equals the specifications in Step 3a of the Test Specifications.
- The following step will verify the second stage of torque control.
- Load the pump according to Step 4a of the Test Specifications. Verify that the flow from the discharge ports is equal. If the flow rates are not within specifications, adjust the second stage of the torque control. Loosen the small locknut on the adjustment screws for torque control (55a) and (55b) in order to adjust the torque control. Turn the set screw clockwise in order to increase flow. Turn the set screw counterclockwise in order to decrease flow. Adjust the set screw until flow equals the specifications in Step 4a of the Test Specifications.
Show/hide tableIllustration 16 g03426127 Hydraulic schematic - The following steps will verify the Negative Flow Control. Before these steps can be performed, refer to Illustration 16 for proper connections.
- Load both discharge ports to the values in Step 5a of the Test Specifications. Load the pilot pump discharge port (64a) according to Step 5a of the Test Specifications. The shims for the negative flow control will need to be adjusted if the flow is not within the specifications. Remove the plate (68a) and (68b) in order to adjust the shims for the negative flow control. Adjust the shims until the flow is correct.
- Verify the discharge pressure. Adjust the flow control pressure according to Step 5b of the Test Specifications. If the flow rate is incorrect, adjust the adjustment screw for minimum angle (67a) and (67b). Turn the screw clockwise in order to increase the flow. Turn the set screw counterclockwise in order to decrease the flow.
Show/hide tableIllustration 17 g03426145 Hydraulic schematic Show/hide tablePump test pressures in this guideline may exceed the normal operating range of the hydraulic test hoses utilized when connecting the tested pump to the test bench. However, the order of magnitude of these pressures is significantly below the burst strength of the Caterpillar XT6 product.
High pressure oil can escape through improperly assembled hoses and fittings. High pressure oil can also escape through poorly maintained hoses and fittings. High pressure oil may also leak through hose that has become damaged over the life of the hose due to the pressure levels that occur during test bench operation.
Personal injury or death can result during adjustment of the high pressure relief valve if recommended hose maintenance practices are not followed. Escaping fluid under pressure can penetrate body tissue causing serious injury, and possible death.
Adjustment of the high pressure cut or pressure override valve shall only be performed when the pump is operating at a zero discharge pressure condition. Continuation of the pump test procedure can be resumed when this high pressure adjustment is completed.
- The following step will verify the cross sensing. Before this step can be performed, refer to Illustration 17 for proper connections. Only connect pilot pump oil to one pump's negative flow control port at a time. Vent the other pump's negative flow control port to the atmosphere. After testing the cross sensing function on one pump, relocate the pilot pump oil to the other pump's negative flow control port. Repeat the test.
- Apply current to the electrical connector for solenoid (62). Adjust the current in order to adjust power shift pressure. Use pilot pump to apply pressure to one pump's negative flow control pressure port according to Step 6a of the Test Specifications. Load the discharge ports. The discharge flow will decrease on the pump at high pressure. The other pump's flow will remain constant.
Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin. |
Reduce RPM and all pressures to zero. Remove the component from the test bench. Drain the oil from the pump. Plug all of the ports.
Test Specifications
Part Number | ____________________ | ||||||
Pump Rotation: | ____________________ | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ |
Drive Pump Flow lpm (gpm)(1) | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ | |
Driven Pump Flow lpm (gpm)(1) | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ |
Drive Pump Discharge Pressure kPa (PSI) | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ | |
Driven Pump Discharge Pressure kPa (PSI) | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ | |
Pilot Pump Flow lpm (gpm) | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ | |
Pilot Pump Discharge Pressure kPa (PSI) | ___________ | ___________ | ___________ | ___________ | ___________ | ___________ | |
Flow Control Pressure kPa (PSI) | ___________ | ___________ | ___________ | ||||
Power shift Pressure kPa (PSI) | ___________ | ___________ | ___________ | ||||
Current Input mA | ___________ | ___________ | ___________ |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
173-3381 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 55.5 (14.67) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 55.5 (14.67) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
194-8300 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 51 (13.5) | 92.5 (24.4) | 75 (19.8) | 36 (9.5) | 23 (6.1) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 51 (13.5) | 92.5 (24.4) | 75 (19.8) | 36 (9.5) | 23 (6.1) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input Amps | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
200-3343 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 64 (16.5) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | 91.5 (24) |
Driven Pump Flow lpm (gpm)(1) | 64 (16.5) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | 17.5 (4.6) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 4900 (710) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 790 (115) | ||||
Current Input mA | 400 | 400 | 320 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
200-3366 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 55.5 (14.67) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 55.5 (14.67) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
200-3369 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
200-3376 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 55.6 (14.7) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 55.6 (14.7) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Aux Pump Flow lpm (gpm) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | |
Aux Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
200-3377 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | 17.5 (4.6) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Aux Pump Flow lpm (gpm) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | |
Aux Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
200-3379 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 64 (16.9) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 64 (16.9) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Aux Pump Flow lpm (gpm) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | |
Aux Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
200-3414 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 13 (3.4) | 13 (3.4) | 13 (3.4) | 13 (3.4) | 13 (3.4) | 13 (3.4) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
204-2773 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
215-9991 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Aux Pump Flow lpm (gpm) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | |
Aux Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
244-5326 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 51.5 (13.6) | 92.5 (24.4) | 75 (19.8) | 36 (9.5) | 23 (6.1) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 51.5 (13.6) | 92.5 (24.4) | 75 (19.8) | 36 (9.5) | 23 (6.1) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140(455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
244-8477 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 64 (16.9) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 64 (16.9) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow (if equipped) lpm (gpm) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | 10.5 (2.8) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
244-8479 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 115 (30.4) | 101 (26.7) | 56.5 (14.9) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 13 (3.4) | 13 (3.4) | 13 (3.4) | 13 (3.4) | 13 (3.4) | 13 (3.4) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
244-8481 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 35 (9.2) | 35 (9.2) | 35 (9.2) | 35 (9.2) | 35 (9.2) | 35 (9.2) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
244-8483 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 55.5 (14.67) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 55.5 (14.67) | 100 (26.4) | 84 (22.2) | 40.5 (10.7) | 27.5 (7.3) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 15700 (2277) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140 (455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
247-8780 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | |
Driven Pump Flow lpm (gpm)(1) | 60 (15.8) | 107.5 (28.4) | 88.5 (23.4) | 49 (12.9) | 29.5 (7.8) | 15 (4.0) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 34300 (4975) | |
Driven Pump Discharge Pressure kPa (PSI) | 9800 (1421) | 17640 (2558) | 29400 (4264) | 6900 (1000) | 6900 (1000) | 3920 (568) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
OCS Pump Flow lpm (gpm) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | 25.5 (6.7) | |
OCS Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3140(455) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1270 (184) | 1270 (184) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
256-0072 | |||||||
Canceled Replaced by 272-6959 |
256-0087 | |||||||
Canceled Replaced by 272-6957 |
256-0092 | |||||||
Canceled Replaced by 272-6955 |
272-6955 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 55.6 (14.7) | 100 (26.6) | 78 (20.6) | 40 (10.6) | 27.5 (7.2) | 15 (4) | |
Driven Pump Flow lpm (gpm)(1) | 55.6 (14.7) | 100 (26.6) | 78 (20.6) | 40 (10.6) | 27.5 (7.2) | 15 (4) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 | 30000 (4351) | 7000 (1015) | 7000 (1015) | 35000 (5076) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 | 30000 (4351) | 7000 (1015) | 7000 (1015) | 4000 (580) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (569) | 3920 (569) | 3920 (569) | 3920 (569) | 3920 (569) | 3920 (569) | |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (569) | 3920 (569) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
272-6957 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 59.7 (15.7) | 107.5 (28.3) | 90 (23.7) | 55.5 (14.6) | 29.5 (7.8) | 15 (4) | |
Driven Pump Flow lpm (gpm)(1) | 59.7 (15.7) | 107.5 (28.3) | 90 (23.7) | 55.5 (14.6) | 29.5 (7.8) | 15 (4) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 2000 (2900) | 30000 (4351) | 7000 (1015) | 7000 (1015) | 35000 (5076) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 2000 (2900) | 30000 (4351) | 7000 (1015) | 7000 (1015) | 4000 (580) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (569) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
272-6959 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 64 (16.9) | 115 (30.4) | 98.5 (25.9) | 61.5 (16.3) | 28.5 (7.5) | 15 (4) | |
Driven Pump Flow lpm (gpm)(1) | 64 (16.9) | 115 (30.4) | 98.5 (25.9) | 61.5 (16.3) | 28.5 (7.5) | 15 (4) | 19 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 2000 (2900) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5076) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 2000 (2900) | 29992 (4350) | 7000 (1015) | 7000 (1015) | 4000 (580) | |
Pilot Pump Flow lpm (gpm) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | 17 (4.5) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (569) | 3920 (569) | 3920 (569) | 3920 (569) | 3920 (569) | 3920 (569) | |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
339-0512 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 58.8 (15.5) | 105(27.6) | 80 (21.1) | 42.5 (11.2) | 28.5 (7.5) | 15 (3.9) | |
Driven Pump Flow lpm (gpm)(1) | 58.8 (15.5) | 105(27.6) | 80 (21.1) | 42.5 (11.2) | 28.5 (7.5) | 15 (3.9) | 20.5 (5.4) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.8 (1.8) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
339-0513 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 63 (16.6) | 113.5(29.9) | 90 (23.7) | 58.5 (15.4) | 27.5 (7.2) | 15 (3.9) | |
Driven Pump Flow lpm (gpm)(1) | 63 (16.6) | 113.5(29.9) | 90 (23.7) | 58.5 (15.4) | 27.5 (7.2) | 15 (3.9) | 20 (5.3) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 20000 (2900) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 14000 (1450) | 20000 (2900) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 4100 (595) | 4100 (595) | 3920 (568) | |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
339-0514 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 67.5 (17.8) | 121.5 (32) | 98.5 (25.9) | 70 (18.4) | 30(7.9) | 15.0 (3.9) | |
Driven Pump Flow lpm (gpm)(1) | 67.5 (17.8) | 121.5 (32) | 98.5 (25.9) | 70 (18.4) | 30 (7.9) | 15.0 (3.9) | 20 (5.3) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 2200 (3190) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 2200 (3190) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | ||||
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | ||||||
Flow Control Pressure kPa (PSI) | 3200 (568) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
371-5210 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 58.8 (15.5) | 105(27.6) | 80 (21.1) | 42.5 (11.2) | 28.5 (7.5) | 15 (3.9) | |
Driven Pump Flow lpm (gpm)(1) | 58.8 (15.5) | 105(27.6) | 80 (21.1) | 42.5 (11.2) | 28.5 (7.5) | 15 (3.9) | 20.5 (5.4) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.8 (1.8) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) | 12.2 (3.2) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
376-8862 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 56 (14.7) | 100 (26.3) | 78 (20.5) | 40 (10.5) | 27.5(7.2) | 15 (3.9) | |
Driven Pump Flow lpm (gpm)(1) | 56 (14.7) | 100 (26.3) | 78 (20.5) | 40 (10.5) | 27.5(7.2) | 15 (3.9) | 20 (5.3) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 10.1 (2.7) | 18 (4.7) | 18 (4.7) | 18 (4.7) | 18 (4.7) | 18 (4.7) | 18 (4.7) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
394-7450 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 69 (18) | 125 (33) | 100 (26) | 61 (16) | 31 (8) | 17 (4.4) | |
Driven Pump Flow lpm (gpm)(1) | 69 (18) | 125 (33) | 100 (26) | 61 (16) | 31 (8) | 17 (4.4) | 22 (5.9) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 19000 (2755) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 19000 (2755) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 7 (1.8) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (570) | 3920 (570) | ||||
Power shift Pressure kPa (PSI) | 1300 (190) | 1300 (190) | 2400 (348) | ||||
Current Input mA | 420 | 420 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
397-3680 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 58 (15.3) | 105 (27.6) | 76 (20) | 40 (10.5) | 27.5(7.2) | 15 (3.9) | |
Driven Pump Flow lpm (gpm)(1) | 58 (15.3) | 105 (27.6) | 76 (20) | 40 (10.5) | 27.5(7.2) | 15 (3.9) | 20 (5.3) |
Drive Pump Discharge Pressure kPa (PSI) | 8000 (1160) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 8000 (1160) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.7 (1.7) | 12 (3.1) | 12 (3.1) | 12 (3.1) | 12 (3.1) | 12 (3.1) | 12 (3.1) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) | 3920 (568) |
Flow Control Pressure kPa (PSI) | 3200 (464) | 3920 (568) | 3920 (568) | ||||
Power shift Pressure kPa (PSI) | 1300 (189) | 1300 (189) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
397-3681 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 67 (17) | 121 (32) | 97 (25) | 56 (14) | 27 (7) | 15 (3) | |
Driven Pump Flow lpm (gpm)(1) | 67 (17) | 121 (32) | 97 (25) | 56 (14) | 27 (7) | 15 (3) | 20 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 18000 (2610) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 18000 (2610) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.7 (1.7) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) |
Flow Control Pressure kPa (PSI) | 3200 (465) | 3920 (570) | 3920 (570) | ||||
Power shift Pressure kPa (PSI) | 1300 (190) | 1300 (190) | 2400 (350) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
422-1294 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 67 (17) | 121 (32) | 97 (25) | 56 (14) | 27 (7) | 15 (3) | |
Driven Pump Flow lpm (gpm)(1) | 67 (17) | 121 (32) | 97 (25) | 56 (14) | 27 (7) | 15 (3) | 20 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 18000 (2610) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 18000 (2610) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.7 (1.7) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) |
Flow Control Pressure kPa (PSI) | 3200 (465) | 3920 (570) | 3920 (570) | ||||
Power shift Pressure kPa (PSI) | 1300 (190) | 1300 (190) | 2400 (350) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
422-1296 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 69 (18) | 124 (32) | 99 (26) | 61 (16) | 30 (7) | 16 (4) | 55 (14) |
Driven Pump Flow lpm (gpm)(1) | 69 (18) | 124 (32) | 99 (26) | 61 (16) | 30 (7) | 16 (4) | 22.5 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 19000 (2755) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5075) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 19000 (2755) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.4 (1.6) | 11.5 (3) | 11.5 (3) | 11.5 (3) | 11.5 (3) | 11.5 (3) | 11.5 (3) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) |
Flow Control Pressure kPa (PSI) | 3200 (465) | 3920 (570) | 3920 (570) | ||||
Power shift Pressure kPa (PSI) | 1300 (190) | 1300 (190) | 2400 (350) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
436-6669 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 58 (15) | 105 (27) | 80 (21) | 42 (11) | 28 (7) | 15 (4) | |
Driven Pump Flow lpm (gpm)(1) | 58 (15) | 105 (27) | 80 (21) | 42 (11) | 28 (7) | 15 (4) | 20 (5) |
Drive Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5076) | |
Driven Pump Discharge Pressure kPa (PSI) | 10000 (1450) | 17000 (2465) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.4 (1.6) | 11.5 (3) | 11.5 (3) | 11.5 (3) | 11.5 (3) | 11.5 (3) | 11.5 (3) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) |
Flow Control Pressure kPa (PSI) | 3200 (465) | 3920 (570) | 3920 (570) | ||||
Power shift Pressure kPa (PSI) | 1300 (188) | 1300 (188) | 2400 (348) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
438-1293 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 69 (18) | 125 (33) | 92 (24) | 52 (13) | 34 (9) | 18 (4) | |
Driven Pump Flow lpm (gpm)(1) | 69 (18) | 125 (33) | 92 (24) | 52 (13) | 34 (9) | 18 (4) | 23 (6) |
Drive Pump Discharge Pressure kPa (PSI) | 8000 (1160) | 18000 (2610) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5076) | |
Driven Pump Discharge Pressure kPa (PSI) | 8000 (1160) | 18000 (2610) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.7 (1.7) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) |
Flow Control Pressure kPa (PSI) | 3200 (465) | 3920 (570) | 3920 (570) | ||||
Power shift Pressure kPa (PSI) | 1300 (190) | 1300 (190) | 2400 (350) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
457-0235 | |||||||
Pump Rotation: | CW | ||||||
Step | 1 | 2 | 3a | 4a | 5a | 5b | 6a |
Pump RPM | 500 | 900 | 900 | 900 | 900 | 900 | 900 |
Drive Pump Flow lpm (gpm)(1) | 58 (15) | 105 (27) | 71 (18) | 30 (7.9) | 30 (7.9) | 15 (3.9) | |
Driven Pump Flow lpm (gpm)(1) | 58 (15) | 105 (27) | 71 (18) | 30 (7.9) | 30 (7.9) | 15 (3.9) | 20 (5.2) |
Drive Pump Discharge Pressure kPa (PSI) | 5000 (725) | 14000 (2030) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 35000 (5076) | |
Driven Pump Discharge Pressure kPa (PSI) | 5000 (725) | 14000 (2030) | 30000 (4350) | 7000 (1015) | 7000 (1015) | 5000 (725) | |
Pilot Pump Flow lpm (gpm) | 6.7 (1.7) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) | 12 (3) |
Pilot Pump Discharge Pressure kPa (PSI) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | 3920 (570) | |
Flow Control Pressure kPa (PSI) | 3000 (435) | 3920 (570) | 3920 (570) | ||||
Power shift Pressure kPa (PSI) | 1500 (218) | 1500 (218) | 2400 (350) | ||||
Current Input mA | 400 | 400 | 540 |
(1) | The flow difference between the pumps should be less than 1 LPM (.26 gpm). |
Test Bench Tooling
Part Number | 173-3381 | 194-8300 | 200-3343 | 200-3366 | 200-3369 | 200-3376 | 200-3377 | 200-3379 |
Drive Adapter | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 |
A1 and A2 Split Flange | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 |
A1 and A2 Flange Adapter | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 |
A3 | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR |
A4 | - | - | 7/8 -14 STOR | - | - | - | - | 7/8 -14 STOR |
A5 | - | - | - | - | - | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR |
S1 4-Bolt Flange | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 |
S3 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR |
S4 | - | - | 1 1/16 -12 STOR | - | - | - | - | 1 1/16 -12 STOR |
S5 | - | - | - | - | - | 1 5/8 -12 STOR | 1 5/8 -12 STOR | 1 5/8-12 STOR |
Pi | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Pn1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Pn2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Ps1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Ps2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Dr1 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR |
Part Number | 200-3414 | 204-2773 | 215-9991 | 244-5326 | 244-8477 | 244-8479 | 244-8481 | 244-8483 |
Drive Adapter | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 |
A1 and A2 Split Flange | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 |
A1 and A2 Flange Adapter | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 |
A3 | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR |
A4 | 7/8 -14 STOR | 7/8 -14 STOR | 7/8 -14 STOR | - | 7/8 -14 STOR | 7/8 -14 STOR | - | - |
A5 | - | - | 1 1/16 -12 STOR | - | - | - | - | - |
S1 4-Bolt Flange | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 |
S3 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR |
S4 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | - | 1 1/16 -12 STOR | 1 1/16 -12 STOR | - | - |
S5 | - | - | 1 5/8 -12 STOR | - | - | - | - | - |
Pi | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Pn1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Pn2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Ps1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Ps2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Dr1 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR |
Part Number | 247-8780 | 256-0072 | 256-0087 | 256-0092 | 272-6955 | 272-6957 | 272-6959 | 339-0512 |
Drive Adapter | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 |
A1 and A2 Split Flange | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 |
A1 and A2 Flange Adapter | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U7439 |
A3 | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR |
A4 | 7/8 -14 STOR | - | 7/8 -14 STOR | - | - | - | ||
A5 | - | - | - | - | - | - | - | - |
S1 4-Bolt Flange | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 |
S3 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR |
S4 | - | - | - | - | - | - | - | - |
S5 | - | - | - | - | - | - | - | - |
Pi | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18STOR | 9/16 -18 STOR |
Pn1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Pn2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Ps1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Ps2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Dr1 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR |
Part Number | 339-0513 | 339-0514 | 371-5210 | 376-8862 | 394-7450 | 397-3680 | 397-3681 | 422-1294 |
Drive Adapter | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 | 131-6456 |
A1 and A2 Split Flange | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 |
A1 and A2 Flange Adapter | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 |
A3 | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4 -16 STOR | 3/4-16 STOR | 3/4-16 STOR |
A4 | - | - | - | - | - | - | - | - |
A5 | - | - | - | - | - | - | - | - |
S1 4-Bolt Flange | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 |
S3 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1-1/16-12 STOR | 1-1/16-12 STOR |
S4 | - | - | - | - | - | - | - | - |
S5 | - | - | - | - | - | - | - | - |
Pi | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Pn1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16-18 STOR | 9/16-18 STOR |
Pn2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16-18 STOR | 9/16-18 STOR |
Ps1 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16-18 STOR | 9/16-18 STOR |
Ps2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR |
Dr1 | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 -12 STOR | 1 1/16 - 12 STOR | 1 1/16 - 12 STOR |
Part Number | 422-1296 | 436-6669 | 438-1293 | 457-0235 | ||||
Drive Adapter | 131-6456 | 131-6456 | 131-6456 | 131-6456 | ||||
A1 and A2 Split Flange | 1P-5766 | 1P-5766 | 1P-5766 | 1P-5766 | ||||
A1 and A2 Flange Adapter | 9U-7439 | 9U-7439 | 9U-7439 | 9U-7439 | ||||
A3 | 3/4-16 STOR | 3/4-16 STOR | 3/4-16 STOR | 3/4-16 STOR | ||||
A4 | - | - | - | - | ||||
A5 | - | - | - | - | ||||
S1 4-Bolt Flange | 1U-9867 | 1U-9867 | 1U-9867 | 1U-9867 | ||||
S3 | 1-1/16-12 STOR | 1-1/16-12 STOR | 1-1/16-12 STOR | 1-1/16-12 STOR | ||||
S4 | - | - | - | - | ||||
S5 | - | - | - | - | ||||
Pi | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | ||||
Pn1 | 9/16-18 STOR | 9/16-18 STOR | 9/16-18 STOR | 9/16-18 STOR | ||||
Pn2 | 9/16-18 STOR | 9/16-18 STOR | 9/16-18 STOR | 9/16-18 STOR | ||||
Ps1 | 9/16-18 STOR | 9/16-18 STOR | 9/16-18 STOR | 9/16-18 STOR | ||||
Ps2 | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | 9/16 -18 STOR | ||||
Dr1 | 1 1/16 - 12 STOR | 1 1/16 - 12 STOR | 1 1/16 - 12 STOR | 1 1/16 - 12 STOR |