No load conditions at
- Rpm with no load ... 4000 to 6000 rpm
- Maximum current ... 540 amperes
- Current draw with no load ... 130 amperes
- Voltage ... 11.5 volts
- Rated voltage ... 12 volts
- Maximum current ... 540 amperes
Power rating ... 2.0 kilowatts
Minimum average cranking rpm ... 130
Starting motor solenoid
- Pull-in current ... 54.5 amperes
- Hold-in current ... 10.5 amperes
(1) Tighten the battery terminal nut to the following torque. ...
(2) Tighten the two mounting bolts to the following torque. ...
(3) Tighten the nut for the switch terminal to the following torque. ...
Maximum resistance of the starter cable at
Illustration 2 | g00381753 |
Schematic of the relays |
(4) When the ignition switch is in the OFF position or the RUN position, the relay switch is closed across the contact "30" and the contact "87a".
(5) When the ignition switch is in the START position, the relay switch is closed across the contact "30" and the contact "87". Then, the starting motor is engaged.
Maximum voltage drop in closed position ... 0.150 to 0.250 volts
(6) Connector pins on the start relay
Resistance between contact "85" and contact "86" ... 7.2 ± 0.7 ohms