Winding Data for 153-3081 Generator through 153-3098 Generator
153-3081 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 304.8 mm (12 inch)     |
304.8 mm (12 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 13     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 19 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1460.5 mm (57.5 inch)     |
-     | |||||
Copper Weight     | 62.6 kg (138 lb)     |
83.6 kg (184.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 24 - #00     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00332 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.175 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3082 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 304.8 mm (12 inch)     |
304.8 mm (12 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 26 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1409.7 mm (55.5 inch)     |
-     | |||||
Copper Weight     | 82.1 kg (181 lb)     |
83.6 kg (184.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 24 - #000     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00232 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.175 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3083 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 304.8 mm (12 inch)     |
304.8 mm (12 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 25 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1460.5 mm (57.5 inch)     |
-     | |||||
Copper Weight     | 82.5 kg (182 lb)     |
83.6 kg (184.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 24 - #00     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00331 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.175 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3084 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 304.8 mm (12 inch)     |
304.8 mm (12 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 2     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 26 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1397.0 mm (55.0 inch)     |
-     | |||||
Copper Weight     | 82.1 kg (181 lb)     |
83.6 kg (184.4 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 24 - #4/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00276 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.175 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3085 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 335.3 mm (13.2 inch)     |
335.3 mm (13.2 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 13     | -     | |||||
Turns/Coil     | 1.8 (1-2-2-2-2)     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 24 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1585.0 mm (62.4 inch)     |
-     | |||||
Copper Weight     | 77.5 kg (170.8 lb)     |
87.5 kg (193 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 24 - #3/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00288 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.270 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3086 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 335.3 mm (13.2 inch)     |
335.3 mm (13.2 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 1.6 (2-1-2-1-2)     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 26 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1524.0 mm (60.0 inch)     |
-     | |||||
Copper Weight     | 71.7 kg (158 lb)     |
87.5 kg (193 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | Series     | |||||
Line Leads (No. & Size)     | 24 - #4/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00261 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.270 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3087 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 414.0 mm (16.3 inch)     |
414.0 mm (16.3 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 1.4 (1-2-1-2-1)     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 26 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1618.0 mm (63.7 inch)     |
-     | |||||
Copper Weight     | 66.7 kg (147 lb)     |
106.6 kg (235 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 24 - #4/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00250 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.499 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3088 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 414.0 mm (16.3 inch)     |
414.0 mm (16.3 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 1.2 (1-1-2-1-1)     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 36 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1676.4 mm (66.0 inch)     |
-     | |||||
Copper Weight     | 77.6 kg (171 lb)     |
106.6 kg (235 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #1     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00188 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.499 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3089 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 431.8 mm (17.0 inch)     |
431.8 mm (17.0 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 1.4 (1-2-1-2-1)     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 32 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1701.8 mm (67.0 inch)     |
-     | |||||
Copper Weight     | 87.1 kg (192 lb)     |
102.5 kg (225.9 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 24 - #4/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00221 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.500 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3090 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 431.8 mm (17.0 inch)     |
431.8 mm (17.0 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 1.2 (1-1-2-1-1)     | -     | |||||
Turns/Pole     | -     | 180     | |||||
No. & Wire Size     | 35 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1714.5 mm (67.5 inch)     |
-     | |||||
Copper Weight     | 81.6 kg (180 lb)     |
102.5 kg (225.9 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #1/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00182 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.500 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3091 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 457.2 mm (18.0 inch)     |
457.2 mm (18.0 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 12     | -     | |||||
Turns/Coil     | 1.4 (1-2-1-2-1)     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 34 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1765.3 mm (69.5 inch)     |
-     | |||||
Copper Weight     | 95.3 kg (210 lb)     |
113.9 kg (251 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 24 - #4/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00182 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.600 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 63 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3092 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 457.2 mm (18.0 inch)     |
457.2 mm (18.0 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 14     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 40 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1828.8 mm (72.0 inch)     |
-     | |||||
Copper Weight     | 82.6 kg (182 lb)     |
113.9 kg (251 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #1/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00152 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.600 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3093 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 558.8 mm (22.0 inch)     |
566.4 mm (22.3 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 14     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 39 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 2026.9 mm (79.8 inch)     |
-     | |||||
Copper Weight     | 89.4 kg (197 lb)     |
132.0 kg (291 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #1     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00177 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.855 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3094 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 558.8 mm (22.0 inch)     |
566.4 mm (22.3 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 40 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1849.1 mm (72.8 inch)     |
-     | |||||
Copper Weight     | 83.7 kg (184.5 lb)     |
132.0 kg (291 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #2/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00151 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.855 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3095 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 566.4 mm (22.3 inch)     |
566.4 mm (22.3 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 13     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 40 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1983.7 mm (78.1 inch)     |
-     | |||||
Copper Weight     | 93.9 kg (207 lb)     |
132.0 kg (291 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #1/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00149 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.855 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3096 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 566.4 mm (22.3 inch)     |
566.4 mm (22.3 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 50 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1920.2 mm (75.6 inch)     |
-     | |||||
Copper Weight     | 108.4 kg (239 lb)     |
132.0 kg (291 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #2/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00485 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.855 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3097 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 584.2 mm (23.0 inch)     |
584.2 mm (23.0 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 14     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 50 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 2146.3 mm (84.5 inch)     |
-     | |||||
Copper Weight     | 121.6 kg (268 lb)     |
135.2 kg (298 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #1/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00120 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.950 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
153-3098 Generator
Show/hide table
MAIN STATOR AND ROTOR WINDING DATA     | |||||||
---|---|---|---|---|---|---|---|
ITEM     | STATOR     | ROTOR     | |||||
Stack Height     | 584.2 mm (23.0 inch)     |
584.2 mm (23.0 inch)     |
|||||
Slots     | 60     | -     | |||||
Coil Throw     | 1 - 11     | -     | |||||
Turns/Coil     | 1     | -     | |||||
Turns/Pole     | -     | 193     | |||||
No. & Wire Size     | 52 - #14     | #6-1/2 RD     | |||||
Mean Length Turn     | 1625.6 mm (64.0 inch)     |
-     | |||||
Copper Weight     | 115.2 kg (254 lb)     |
135.2 kg (298 lb)     |
|||||
Inside Connection (1)     | 2 Parallel Wye     | -     | |||||
Line Leads (No. & Size)     | 48 - #3/0     | -     | |||||
Terminal bolt size     | 3/8 inch     | -     | |||||
Low Voltage connected line resistance at 25 ° C (77 ° F)     | 0.00112 ohms     | -     | |||||
Field lead resistance at 25 ° C (77 ° F)     | -     | 1.950 ohms     | |||||
EXCITER WINDING DATA     | |||||||
Exciter Frequency (Hz)     | 90 Hz     | Permanent Magnet Frequency     | 240 Hz     | ||||
Exciter Poles     | 6     | ||||||
ITEM     | STATOR (FIELD)     | ROTOR (ARMATURE)     | Permanent Magnet Stator     | ||||
Stack Length     | 127.0 mm (5.0 inch)     |
127.0 mm (5.0 inch)     |
25.4 mm (1.0 inch)     |
||||
Coils/Group     | -     | 1     | 1     | ||||
Slots (Coils)     | 6     | 36     | 48     | ||||
Turns (Coils)     | 140     | 8     | 12     | ||||
No. & Size Wire     | 15 - 1/2     | 2 - #16     | 4 - #18     | ||||
Coil Throw     | 1 - 2     | 1 - 6     | 1 - 4     | ||||
Mean Length Turn (Calc.)     | 464.8 mm (18.3 inch)     |
-     | 208.3 mm (8.2 inch)     |
||||
Copper Weight     | 5.2 kg (11.5 lb)     |
2.9 kg (6.4 lb)     |
1.8 kg (3.95 lb)     |
||||
Insulation     | Heavy Polyester Polyamide Imide     | ||||||
Connection (2)     | Series     | 2 Parallel     | Series Wye     | ||||
Line Leads     | #14     | 3 - #10     | 3 - #14     |
Show/hide table
( 1 ) | See Specifications, "Connection Diagrams for Main Stator and Main Rotor" Connection Diagram 49 |
( 2 ) | See Specifications, "Connection Diagrams for Exciter" Connection Diagram D |
Caterpillar Information System:
Power Module Switchgear (Low Voltage and Medium Voltage) Fire Prevention and Explosion Prevention
G3600 Engines System Overview
3054 and 3056 Engines 550 Generator Set Control Panel Alarm Operation
3054 and 3056 Engines 550 Generator Set Control Panel Normal Operation
SPT343 Truck Mounted Pumper Junction Box
3054 and 3056 Engines 550 Generator Set Control Panel Automatic Operation
Machine Security System Factory Password - Obtain
3054 and 3056 Engines 550 Generator Set Control Panel General Information
C0.5, C0.7, C1.1/3011C, C1.5/3013C, C1.6 and C2.2/3024C/3024CT Industrial Engines and Engines for Caterpillar Built Machines Housing (Front)
2001/11/01 The Content Of The 9U-5105 Basic Engine Tool Group Has Changed {0701}
2001/11/01 A Two-Piece Clip is now used to Retain the Tube Assemblies in the Hydrax System {1264, 1307}
Machine Security System Electronic Control Module (ECM) - Flash Program
SCT673 Truck Mounted PumperPOD Fan Belt - Inspect/Adjust/Replace
3408E and 3412E Engines for Caterpillar Built Machines Basic Engine
3408E and 3412E Engines for Caterpillar Built Machines Finding Top Center Position for No. 1 Piston
2001/11/01 The Timing Marks Have Been Improved On The Front and Rear Balancer Gears {1220}
Electronic Modular Control Panel II (EMCP II) Starting Motor Remains Engaged (for EUI Engines)
3408E and 3412E Engines for Caterpillar Built Machines Engine Valve Lash - Inspect/Adjust
3408E and 3412E Engines for Caterpillar Built Machines Cylinder Liner Projection - Inspect
Electronic Modular Control Panel II (EMCP II) Data Link
SR4 and SR4B Electric Power Generation Rewind Data Winding Data for 167-1351 Generator through 167-1354 Generator
G3300 Engines Specifications
G3300 Engines Plate Locations and Film Locations
SCT673 Truck Mounted PumperPOD Power End Oil and Filter - Change