Bench Test Procedure for Hydraulic Piston Pumps {0784, 5050, 5070} Caterpillar


Bench Test Procedure for Hydraulic Piston Pumps {0784, 5050, 5070}

Usage:

D6T 2B3
Articulated Truck
725 (S/N: WWA1-UP; B1L1-UP; AFX1-UP)
725C (S/N: LFB1-UP; TFB1-UP)
725C2 (S/N: 2T31-UP; 2L61-UP)
730 (S/N: 3F31-UP; 3T31-UP; WWB1-UP; AGF1-UP)
730 EJECTOR (S/N: 3F41-UP; 3T41-UP; B1M1-UP; B1W1-UP)
730C (S/N: LFF1-UP; TFF1-UP)
730C EJECTOR (S/N: LFH1-UP; TFH1-UP)
730C2 (S/N: 2T41-UP; 2L71-UP)
730C2 EJ (S/N: 2T51-UP; 2L81-UP)
735 (S/N: 3F51-UP; 3T51-UP)
735C (S/N: LFJ1-UP; TFJ1-UP)
740 EJECTOR (S/N: 3F71-UP; 3T71-UP)
740 GC (S/N: 3F81-UP; 3T81-UP)
740C EJECTOR (S/N: LFN1-UP; TFN1-UP)
745 (S/N: 3F61-UP; 3T61-UP)
745C (S/N: LFK1-UP; TFK1-UP)
Landfill Compactor
836K (S/N: T6X1-UP; L6Z1-UP; LWZ1-UP; TWZ1-UP)
Load Haul Dump
R1700 (S/N: KT41-UP)
Motor Grader
24 (S/N: E9Z1-UP; N9Z1-UP)
Rotary Drill
MD6250 (S/N: DN71-UP; DN81-UP)
MD6310 (S/N: DLK1-UP; DLZ1-UP)
Track-Type Loader
963D (S/N: LCS1-UP)
963K (S/N: LBL1-UP; YDR1-UP)
Track-Type Tractor
D10T2 (S/N: RAB1-UP)
D6 (S/N: AG91-UP; GZ91-UP; HR91-UP; LF91-UP; RA91-UP; SA91-UP; RDC1-UP; HNK1-UP; RBP1-UP; KMT1-UP; KEW1-UP; KTW1-UP)
D6 XE (S/N: B721-UP; ES91-UP; LNC1-UP; XEC1-UP; HFE1-UP; LRG1-UP; HMH1-UP; HZL1-UP; TPL1-UP; D5M1-UP; HLY1-UP; WGY1-UP)
D6R2 (S/N: PPP1-UP; SSS1-UP; TTT1-UP)
D6T (S/N: 2D21-UP; CR31-UP; 2B31-UP; MB51-UP; AK71-UP; MH71-UP; CG81-UP; 7C91-UP; SGA1-UP; KSB1-UP; ZJB1-UP; JZC1-UP; DTD1-UP; RAD1-UP; STE1-UP; EJJ1-UP; SLJ1-UP; GMK1-UP; RRK1-UP; JML1-UP; MEL1-UP; JNM1-UP; TSM1-UP; WLM1-UP; WRN1-UP; K1R1-UP; KMR1-UP; PLR1-UP; WES1-UP; HYT1-UP; SGT1-UP; JRW1-UP; RCW1-UP; NDY1-UP; TMY1-UP; HTZ1-UP; SGZ1-UP)
D7E (S/N: HKA1-UP; KZA1-UP; TJA1-UP; MDB1-UP; SCG1-UP; SSH1-UP; TAN1-UP; JDP1-UP; LTW1-UP)
D8R (S/N: JR81-UP; DWJ1-UP)
D8T (S/N: AW41-UP; JJ51-UP; MB81-UP; J8B1-UP; FMC1-UP; MLN1-UP; FCT1-UP; JET1-UP; KPZ1-UP)
Underground Articulated Truck
AD22 (S/N: MW51-UP)
Wheel Dozer
814K (S/N: LW41-UP; T1Z1-UP)
834K (S/N: TW41-UP; L4Y1-UP; LWY1-UP; TWY1-UP)
854K (S/N: KK31-UP; RM31-UP; KK61-UP; RM61-UP)
Wheel Feller Buncher
2470C (S/N: W2M1-UP)
2570C (S/N: F1B1-UP)
2570D (S/N: D251-UP)
2670C (S/N: B3E1-UP)
2670D (S/N: D261-UP)
553C (S/N: PGR1-UP)
563C (S/N: W631-UP; JCB1-UP)
573C (S/N: W731-UP; RJT1-UP)
Wheel Loader
924K (S/N: ENC1-UP; HJF1-UP; PWR1-UP)
926M (S/N: LTE1-UP)
930K (S/N: T681-UP; DYB1-UP; EYE1-UP; FRK1-UP; P3K1-UP; RHN1-UP; TNY1-UP)
930M (S/N: KTG1-UP; HEY1-UP)
938K (S/N: W8K1-UP; SWL1-UP; REP1-UP; XXT1-UP; HFW1-UP)
938M (S/N: J3R1-UP)
950 GC (S/N: M5K1-UP; M5T1-UP)
950H (S/N: M1G1-UP; MXL1-UP; JLX1-UP)
950L (S/N: TNS1-UP; LXX1-UP)
962H (S/N: SSA1-UP; PCW1-UP)
962L (S/N: MTN1-UP; SXS1-UP)
988K XE (S/N: EWX1-UP)
992K (S/N: KK21-UP; RM21-UP; KK41-UP; RM51-UP)
993K (S/N: Z4D1-UP; RDM1-UP; MCZ1-UP; Z4Z1-UP)
994K (S/N: MM91-UP; MRK1-UP; SMX1-UP)
Wheel Tractor-Scraper
631K (S/N: WTR1-UP; WTW1-UP)
637K (S/N: WTS1-UP; WTT1-UP; WTX1-UP; WTY1-UP)

Introduction

Table 1
Revision  Summary of Changes in REHS9388 
21  Updated effectivity. 
20  Updated effectivity. 
19  Updated effectivity. 
18  Updated effectivity. 

© 2019 Caterpillar All Rights Reserved. This guideline is for the use of Cat dealers only. Unauthorized use of this document or the proprietary processes therein without permission bay be violation of intellectual property law. Information contained in this document is considered Caterpillar: Confidential Yellow.

This Special Instruction includes test procedures for piston pumps. This Special Instruction also provides specifications. The technician should have a good understanding of hydraulic piston pumps. The technician should be educated in the operation of the hydraulic test bench. The test benches in this document are available through the CaterpillarDealer Service Tools. Gather all necessary tooling before you need to hook up the pump. Some of the required tooling appears in a table at the end of this document. There are many possible variations of tooling that could be used. Not every possible variation can be listed.

For technical questions when using this document, work with your Dealer Technical Communicator (TC).

To report suspected errors, inaccuracies, or suggestions regarding the document, submit a form for feedback in the Service Information System (SIS Web) interface.

Canceled Part Numbers and Replaced Part Numbers

This document may not include all Canceled part numbers and replaced part numbers. Use NPR on SIS for information about Canceled part numbers and replaced part numbers. NPR will provide the current part numbers for replaced parts.

Safety



Illustration 1g02139237

------ WARNING! ------

Personal injury or death can result from improperly checking for a leak.

Always use a board or cardboard when checking for a leak. Escaping air or fluid under pressure, even a pin-hole size leak, can penetrate body tissue causing serious injury, and possible death.

If fluid is injected into your skin, it must be treated immediately by a doctor familiar with this type of injury.


------ WARNING! ------

Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin.


------ WARNING! ------

Pump test pressures in this guideline may exceed the normal operating range of the hydraulic test hoses utilized when connecting the tested pump to the test bench. However, the order of magnitude of these pressures is significantly below the burst strength of the Caterpillar "XT6" product.

High pressure oil can escape through improperly assembled hoses and fittings. High pressure oil can also escape through poorly maintained hoses and fittings. High pressure oil may also leak through hose that has become damaged over the life of the hose due to the pressure levels that occur during test bench operation.

Personal injury or death can result from improper hose & fitting inspection or improper hose replacement procedures. Escaping fluid under pressure can penetrate body tissue causing serious injury, and possible death.

Thoroughly inspect all testing hoses, fittings, and quick disconnects prior to any testing operation. Check the assembly date tag or hose assembly log date for a hose life indicator. Replace all Test Bench hoses at a minimum of every 2 years or earlier if the hose or fittings appear to be damaged.


Summary

This procedure is specific to the type of pump and the type of control. Refer to the test specifications and the tooling at the end of this document.

Note: A paper copy of this document may not be the latest version. Go to the Service Information System (SIS) to view the latest version.

References

Table 2
References 
Media Number  Title 
REHS1761  "Required Tooling for Bench Testing Hydraulic Components" 
SEBF8810  "Hydraulic Pump, Motor, and Cylinder Bench Test Procedure Reference Manual" 
SEHS8892  "Operating Instructions for Caterpillar 1U-9400 Series Hydraulic Test Center" 
NEHS0563  "Tool Operating Manual for 9U-5000 Series Hydraulic Test Bench" 

Connections for the Caterpillar Hydraulic Test Center



Illustration 2g01373529
Connections for the Test Center
(1) Flow control for discharge
(2) "F3" flow meter inlet
(3) "F4" flow meter inlet
(4) Oil supply from the auxiliary pump
(5) "F3" inlet for the flow meter with flow limiter
(6) "F3"outlet for the flow meter with pressure control
(7) Load sensing pressure
(8) Signal pressure
(9) "F4" outlet for the flow meter
(10) Return to tank
(11) Connections for case drain
(12) Oil supply


Illustration 3g01373530
Control and Gauges for the Test Center
(13) Meter for speed and torque
(14) Gauge for signal pressure
(15) Control for signal pressure
(16) Pressure gauge for auxiliary pump
(17) Auxiliary pump flow
(18) "F3" discharge pressure gauge
(19) "F3" discharge flow
(20) "F4" discharge pressure gauge
(21) "F4" discharge flow
(22) Auxiliary pump flow control
(23) "F3" margin pressure
(24) "F3" Load control for discharge pressure
(25) "F4" Load control for discharge pressure

Connections for the Caterpillar Hydraulic Test Bench



Illustration 4g01373531
Connections for the Test Bench
(26) "Flow meter 1" loop and "Flow meter 2" loop
(27) Oil Supply


Illustration 5g01373536
Connections for the Test Bench
(28) "Flow meter 2" loop
(29) "Flow meter 1" loop
(30) "Flow meter 2" outlet
(31) Signal pressure line
(32) "Flow meter 2" inlet
(33a) "Flow meter 1" outlet
(33b) Auxiliary oil supply outlet
(34) Auxiliary oil supply inlet
(35) "Flow meter 1" inlet


Illustration 6g01373540
Control and Gauges for the Test Bench
(36) Auxiliary oil supply pressure
(37) Signal pressure
(38) Control for signal pressure
(39) "Flow meter 1" discharge pressure
(40) Control for auxiliary oil supply pressure
(41) "Flow meter 2" discharge pressure
(42) Auxiliary oil supply control
(43) "Flow meter 2" discharge flow
(44) Discharge flow for auxiliary pump
(45) "Flow meter 1" discharge flow
(46) "Flow meter 1" load control
(47) Speed and direction control
(48) "Flow meter 2" load control

Port Locations



Illustration 7g03853160
Port locations for pump configurations with side-mounted control and opposing suction and discharge ports.
(49) Case drain port
(50) Suction port
(51) Pressure port for load sensing
(52) Case drain port
(53) Adjustment screw for margin pressure
(54) Adjustment screw for the high-pressure cut
(55) Discharge port


Illustration 8g03855774
Port Locations for pump configurations with rear mounted control and rear-facing suction and discharge ports.
(49) Case drain port
(50) Suction port
(51) Pressure port for load sensing
(52) Case drain port
(53) Adjustment screw for margin pressure
(54) Adjustment screw for the high-pressure cut
(55) Discharge port


Illustration 9g01374072
Hydraulic Schematic
(49) Case drain port
(50) Suction port
(51) Pressure port for load sensing
(52) Case drain port
(53) Adjustment screw for margin pressure
(54) Adjustment screw for the high-pressure cut
(55) Discharge port

4C-3582 Load Sensing Valve



Illustration 10g01375820
4C-3582 Load Sensing Valve


Illustration 11g01375822
4C-3582 Load Sensing Valve


Illustration 12g01375829
Schematic for 4C-3582 Load Sensing Valve


Illustration 13g01375830
4C-3582 Load Sensing Valve and 1U-5796 Pressure Differential Gauge
(56) Outlet port
(57) Adjustment for the discharge flow
(58) Inlet port
(59) high-pressure valve port
(60) Adjustment for the discharge pressure
(61) low-pressure valve port
(62) Pressure port for load sensing
(63) Pressure differential gauge group
(64) low-pressure gauge port
(65) high-pressure gauge port

Pump Setup

Note: A load sensing pressure line from the pump (51) should be connected to the load sensing pressure port (7) when you use the Caterpillar Hydraulic Test Center. See Illustration 2. A load sensing pressure line from the pump should be connected to the pressure port for load sensing (62) on the 4C-3582 Load Sensing Valve when using the Caterpillar Hydraulic Test Bench.

  1. Connect a 1 inch high-pressure "XT5" hose from the pump discharge port (55) to inlet port (58) on the 4C-3582 Load Sensing Valve.

  2. Connect a 1 inch high-pressure "XT5" hose from outlet port (56) on the 4C-3582 Load Sensing Valve to the flow meter inlet on the test bench.

  3. Connect a 1 inch high-pressure hose from the flow meter outlet on the test bench back to the tank.

  4. Connect a 6D-7726 Hose Assembly to the pressure port for load sensing (62). Connect the other end of 6D-7726 Hose Assembly to the pressure port for load sensing (51) on the pump.

    Note: Do not use 1U-5754 Hose Assembly or 1U-5755 Hose Assembly for load sensing signal lines. The flow rate through these hoses will not compensate for the possible leakage through the control valve. Erratic readings will result.

  5. Connect the 1U-5796 Pressure Differential Gauge Group (63) to the high-pressure valve port (59) and low-pressure valve port (61) on the 4C-3582 Load Sensing Valve. The port marked "hi" (65) on the 1U-5796 Pressure Differential Gauge Group should be hooked up to the port marked "hi" (59) on the 4C-3582 Load Sensing Valve. The port marked "low" (64) on the 1U-5796 Pressure Differential Gauge Group should be hooked up to the port marked "low" (61) on the 4C-3582 Load Sensing Valve.

    Note: The ports marked "low" (61) and "sense line" (62) on the 4C-3582 Load Sensing Valve are reading the same pressure.

  6. Purge all air from the suction line. Loosen the suction hose at the pump until oil leaks from the connection. Tighten the suction hose.

  7. Fill the pump case with oil. Pour oil directly into a case drain port until the case is full.

  8. Connect an in-line flow meter to the case drain port (49) and (52). Direct the oil from the in-line flow meter back to the tank.

  9. Do not rotate the pump in the wrong direction. The correct direction of rotation will be stated on the pump. The correct direction of rotation will also be in the test specifications. The direction of rotation is viewed from the input shaft end. Visually check the pump for proper rotation.

Test Procedure

Note: The steps in the procedure correlate with the steps under the "Test Specifications" according to your specific part number.

The contamination level of the hydraulic oil in the test bench should be ISO 16/13 or better. The oil in the test bench should be one of the following.

  • SAE 10W at 50 °C (122 °F) or

  • Mobil DTE-11 at 46 °C (115 °F)


Illustration 14g01374887
Pump characteristics
(P) Discharge pressure
(Q) Discharge flow

Note: For Steps 1, 2, 4, and 5 be sure Adjustment knob for discharge flow (57) and Adjustment for the discharge pressure (60) are completely backed out on the 4C-3582 Load Sensing Valve.

  1. Start rotating the pump according to the RPM in Step 1 of the"Test Specifications". Listen for abnormal noise. Verify flow from the pump. Verify that all connections are tight. Check for leaks around shaft seals. Check for leaks around the control valve.

    Run the pump for at least 5 minutes to raise the temperature of the oil and purge the system of air.

  2. Slowly increase the input RPM to the value in Step 2 of the"Test Specifications". Record the discharge flow. If the actual flow is less than the value in Step 2 of the "Test Specifications", the pump may not be mechanically feasible. The pump is to be internally inspected.

  3. Adjust the input RPM to the value in Step 3. The discharge flow is adjusted by using the 4C-3582 Load Sensing Valve. Bench circuitry will be used for flow limiting when using a 1U-9400 Test Center. Decrease the discharge flow according to the values in Step 3 of the"Test Specifications". Adjust the discharge pressure according to the values in Step 3 of the"Test Specifications". Adjust the screw for margin pressure (53) to the value in Step 3 of the"Test Specifications". The margin pressure will be displayed on the 1U-5796 Pressure Differential Gauge (63).

    Note: The margin pressure may change as discharge pressure changes. Adjust margin pressure at Step 3 within operating conditions only.

  4. Increase the discharge flow by turning adjustment for discharge flow (57) according to Step 4 of the"Test Specifications". Adjust the input RPM to the value in Step 4. Increase the pump discharge pressure to the value in Step 4 of the"Test Specifications". Compare the actual values from the case drain with the values in Step 4 of the"Test Specifications". This value is an indication of the pump efficiency. If the case drain is more than the value given in Step 4 of the "Test Specifications" , the pump may not be mechanically feasible. The pump is to be internally inspected.

  5. Adjust the input RPM to the value in Step 5 of the"Test Specifications". Increase the pump discharge pressure to the value in Step 5 of the"Test Specifications". Turn the adjustment screw for the high pressure cut (54) until the actual high-pressure cut value is equal to the value in Step 5. The discharge flow should decrease to the value in Step 5 in the"Test Specifications"when the high-pressure cut is reached.

------ WARNING! ------

Hot oil and hot components can cause personal injury. Do not allow hot oil or hot components to contact skin.


Reduce RPM and all pressures to zero. Remove the component from the test bench. Drain the oil from the pump. Plug all of the ports.

Test Specifications

Table 3
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
__________  __________  __________  __________  __________     
2 __________ __________  __________     
3 __________ __________  __________    __________ 
4 __________ __________  __________  __________   
5 __________ __________  __________     

Table 4
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
240-2647  CW  1000  71 (18.5) 
2 1500 106 (28) 
3 2000 6900 (1000)  75 (20)  2200±100 (319±15) 
4 1500 18630 (2700)  106 (28)  6.9 (2.8) 
5 1500 20700 (3000) 

Table 5
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
252-2680  CW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900±100 (1000±15)  110 (29)  2000±100 (290±15) 
4 2000 27000±350 (3900±50)  220 (58)  11 (3) 
5 1400 30000±350 (4350±50)  31 (8) 

Table 6
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
281-1623  CCW  1000  71 (19) 
2 2000 142 (38) 
3 2360 6900±100 (1000±15)  84 (22)  2100±100 (305±15) 
4 2000 28350±350 (4110±50)  142 (38)  7 (2) 
5 2000 31500±350 (4570±50) 

Table 7
Test Specifications 
Part Number   
307-3044  Tandem pump made of 358-4992 (Front Pump, See This Document) and 358-4993 (Rear Pump, See This Document) 

Table 8
Test Specifications 
Part Number   
325-9777  Tandem pump made of 325-9774 (Front Pump, See REHS1448) and 324-9778 (Rear Pump, REHS3451) 

Table 9
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
325-9778  CW  1000  100 (26.3) 
2 2000 200 (52.6) 
3 2000 6900±100 (1000±15)  100 (26.3)  2100±100 (305±15) 
4 2000 19410±350 (2813±50)  200 (52.6)  10 (2.6) 
5 2000 21550±350 (3125±50) 

Table 10
Test Specifications 
Part Number   
325-9783  Tandem pump made of 325-9786 (Front Pump, REHS3451) and 324-9774 (Rear Pump, See REHS1448) 

Table 11
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
325-9786  CW  1000  100 (26.3) 
2 2000 200 (52.6) 
3 2000 6900±100 (1000±15)  100 (26.3)  2100±100 (305±15) 
4 2000 17370±350 (2520±50)  200 (52.6)  10 (2.6) 
5 2000 19300±350 (2800±50) 

Table 12
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
338-2879  CW  1000  140 (36.8) 
2 2000 280 (73.7) 
3 2000 6900±100 (1000±15)  140 (36.8)  2100±100 (305±15) 
4 1400 21600±350 (3132±50)  196 (51.6)  10 (2.6) 
5 1400 24000±350 (3480±50) 

Table 13
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
341-7627  CW  1000  87 (22.9) 
2 2000 174 (45.8) 
3 2000 6900±100 (1000±15)  87 (22.9)  2100±100 (305±15) 
4 2000 24750±350 (3589±50)  174 (45.8)  8.7 (2.3) 
5 1400 27500±350 (3988±50) 

Table 14
Test Specifications 
Part Number   
341-7660  Tandem pump made of 341-7627 (Front Pump, See This Document) and 358-4993 (Rear Pump, See This Document) 

Table 15
Test Specifications 
Part Number   
341-7662  Tandem pump made of 341-7664 (Front Pump, See This Document) and 358-4993 (Rear Pump, See This Document) 

Table 16
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
341-7664  CW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900±100 (1000±15)  110 (29)  2100±100 (305±15) 
4 2000 26550±350 (3850±50)  220 (58)  11 (3) 
5 1400 29500±400 (4278±50) 

Table 17
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
342-2680  CW  1000  110 (29) 
2 2000  220 (58) 
3 2000  6900±100 (1000±15)  110 (29)  2000±100 (300±15) 
4 2000  27000±300 (3900±40)  220 (58)  11 (3) 
5 1500  30000±350 (4350±50) 

Table 18
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
355-2397  CW  1000  100 (26.3) 
2 2000 200 (52.6) 
3 2000 6900±100 (1000±15)  100 (26.3)  2000±100 (290±15) 
4 1500 24840±350 (3602±50)  150 (39.6)  8(2.0) 
5 1500 27600±350 (4002±50) 

Table 19
Test Specifications 
Part Number   
355-2407  Multiple pump made of 289-4027 (Rear, See REHS1375), 355-2397 (Front, REHS3451), and 355-2406 (Center, See REHS1448) 

Table 20
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
358-4992  CW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900±100 (1000±15)  110 (29)  2100±100 (305±15) 
4 2000 23850±350 (3458±50)  220 (58)  11 (3) 
5 1400 26500±350 (3843±50) 

Table 21
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
358-4993  CW  1000  75 (19.7) 
2 2000 150 (39.4) 
3 2000 6900±100 (1000±15)  75 (19.7)  2300±100 (334±15) 
4 2000 21690±350 (3145±50)  150 (39.4)  7.5 (2.0) 
5 1400 24100±350 (3495±50) 

Table 22
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
365-2142  CW  1000  71 (18.8) 
2 2000 142 (37.5) 
3 2000 6900±100 (1000±15)  71 (18.8)  2100±100 (305±15) 
4 1400 26100±100 (3790±15)  99 (26.2)  5 (1.3) 
5 1400 29000±100 (4210±15) 

Table 23
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
366-4955  CW  1000  71 (18.8) 
2 2000 142 (37.5) 
3 2000 6900±100 (1000±15)  71 (18.8)  2100±100 (305±15) 
4 1400 21700±100 (3150±15)  99 (26.2)  5 (1.3) 
5 1400 24100±100 (3500±15) 

Table 24
Test Specifications 
Part Number   
367-8076  Tandem pump made of 367-8077 (front pump) and 367-8078 (rear pump). Refer to these part numbers in this instruction 

Table 25
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
367-8077  CCW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900±100 (1000±15)  110 (29)  2100±100 (305±15) 
4 1400 26190±350 (3798±50)  154 (40.6)  8 (2.1) 
5 1400 29100±350 (4220±50) 

Table 26
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
367-8078  CCW  1000  74 (19.5) 
2 2000 148 (39) 
3 2000 6900±100 (1000±15)  74 (19.5)  2400±100 (348±15) 
4 2000 18630±350 (2701±50)  148 (39)  8 (2.1) 
5 2000 20700±350 (3002±50) 

Table 27
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
373-6527  CW  1000  110 (29) 
2 1500 165 (43) 
3 2000 6900 (1000)  66 (18)  2200±100 (320±15) 
4 1500 18630±315 (2700±45)  165 (43)  11.4 (3) 
5 1500 20700±350 (3000±50) 

Table 28
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
373-6528  CW  1000  110 (29) 
2 1500 165 (43) 
3 2000 6900 (1000)  66 (18)  2200±100 (320±15) 
4 1500 22950±315 (3330±45)  165 (43)  11.4 (3) 
5 1500 25500±350 (3700±50) 

Table 29
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
373-6629  CW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900 (1000)  110 (29)  2100±200 (305±30) 
4 1500 25200 (3650)  165 (43)  8.3 (2.2) 
5 1500 28000 (4060) 

Table 30
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
373-6630  CW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900 (1000)  110 (29)  2100±200 (305±30) 
4 1500 25200 (3650)  165 (43)  8.3 (2.2) 
5 1500 28000 (4060) 

Table 31
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
374-2567  CW  1000  110 (29) 
2 1500 165 (43) 
3 2000 6900 (1000)  66 (18)  2200±100 (320±15) 
4 1500 19800±315 (2870±45)  165 (43)  11.4 (3) 
5 1500 22000±350 (3190±50) 

Table 32
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
374-2570  CW  1000  71 (19) 
2 1500 106 (28) 
3 2000 6900 (1000)  71 (19)  2200±100 (320±15) 
4 1500 18630±315 (2700±45)  106 (28)  8 (2) 
5 1500 20700±350 (3000±50) 

Table 33
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
392-0187  CW  1000  140 (37) 
2 2000  280 (74) 
3 2000  6900±100 (1000±15)  140 (37)  2200±100 (320±15) 
4 2000  18750±350 (2700±50)  280 (74)  20 (5) 
5 2000  20850±350 (3000±50) 

Table 34
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
392-0230  CW  1000  74 (19) 
2 2000 148 (38) 
3 2000 6900±100 (1000±15)  74 (19)  2200±100 (320±15) 
4 2000 19650±350 (2850±50)  148 (38)  11 (2.7) 
5 2000 21850±350 (3200±50) 

Table 35
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
397-9564  CW  1000  100 (26) 
2 2000 200 (53) 
3 2000 6900±100 (1000±15)  100 (26)  2100±100 (300±15) 
4 2000 17370±300 (2500±50)  200 (53)  14 (4) 
5 2000 19300±350 (2800±50) 

Table 36
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
416-8986  CW  1000  110 (29) 
2 2000  220 (58) 
3 2000  6900±100 (1000±15)  110 (29)  2000 (290) 
4 2000  27000 (3915)  110 (29)  8 (2) 
5 2000  30000 (4350) 

Table 37
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
418-2202  CCW  1000  71 (18) 
2 2000 142 (37) 
3 2000 6900±100 (1000±15)  71 (18)  2100 (305) 
4 1500 24300 (3525)  106 (28)  5.3 (1.4) 
5 1500 27000 (3915) 

Table 38
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
418-2205  CCW  1000  71 (18) 
2 2000 142 (37) 
3 2000 6900±100 (1000±15)  71 (18)  2100±100 (300±15) 
4 1500 24300±500 (3525±100)  142 (37)  10 (3) 
5 1500 27000±500 (3915±100) 

Table 39
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
424-1866  CW  1000  74(19) 
2 2000 148 (38) 
3 2000 6900 (1000)  74 (19)  2100±100 (300±15) 
4 2000 15300 (2200)  148(38)  11 (2.7) 
5 2000 17000 ±350 (2470±50) 

Table 40
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
444-5235  CW  1000  131 (34) 
2 2000 262 (69) 
3 2000 6900±100 (1000±15)  131 (34)  2100±150 (305±22) 
4 1000 22140±350 (3210±50)  131 (34)  10 (3) 
5 1000 24600±350 (3570±50) 

Table 41
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
444-8538  CW  1000  100 (26) 
2 2000 200 (53) 
3 2000 6900±100 (1000±15)  100 (26)  2100±100 (305±15) 
4 2000 1890 (274)  200 (53)  14 (4) 
5 1000 21550±350 (3125±50) 

Table 42
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
444-8539  CW  1000  100 (26) 
2 2000 200 (52) 
3 2000 6900±100 (1000±15)  100 (26)  2100±100 (305±15) 
4 1000 17370±350 (2520±50)  100 (26)  7 (2) 
5 1000 19300±350 (3800±50) 

Table 43
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
458-8651  CW  1000  140 (37) 
2 1800  252 (66) 
3 1800  6900±100 (1000±15)  126 (33)  2100±100 (305±15) 
4 1800  21600 (3100)  252 (66)  18 (5) 
5 1800  26000±350 (3770±50) 

Table 44
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
458-8658  CW  1000  140 (37) 
2 1800  252 (66) 
3 1800  6900±100 (1000±15)  126 (33)  2100±100 (305±15) 
4 1800  21600 (3100)  252 (66)  18 (5) 
5 1800  26000±350 (3770±50) 

Table 45
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
461-7098  CW  1000  100 (26) 
2 2000  200 (53) 
3 2000  6900±100 (1000±15)  100 (26)  2100±100 (305±15) 
4 2000  25000±350 (3600±100)  200 (53)  14 (4) 
5 2000  27600±500 (4000±100) 

Table 46
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
464-4876  CW  1000  85 (22) 
2 2000 170 (44) 
3 2000 6900±100 (1000±15)  85 (22)  2100±100 (305±15) 
4 2000 21690±350 (3145±50)  170 (44)  12 (3.2) 
5 2000 24100±350 (3495±50) 

Table 47
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
464-4884  CCW  1000  140 (37) 
2 2000  280 (74) 
3 2000  6900±100 (1000±15)  140 (37)  2100±100 (305±15) 
4 2000  21600±350 (3100±100)  280 (74)  20 (5.5) 
5 2000  24000±350 (3500±100) 

Table 48
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
464-4885  CCW  1000  140 (37) 
2 2000  280 (74) 
3 2000  6900±100 (1000±15)  140 (37)  2100±100 (305±15) 
4 2000  21600±350 (3100±100)  280 (74)  20 (5.5) 
5 2000  24000±350 (3500±100) 

Table 49
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
468-3837  CCW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900±100 (1000±15)  110 (29)  2100±100 (305±15) 
4 2000 26190±300 (3800±50)  220 (58)  16 (5) 
5 2000 29100±350 (4220±50) 

Table 50
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
475-0538  CW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900±100 (1000±15)  110 (29)  2100±100 (305±15) 
4 2000 21600 (3130)  220 (58)  15 (4) 
5 2000 24000±500 (3480±70) 

Table 51
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
476-6616  CW  1000  100 (26) 
2 2000 200 (53) 
3 2000 6900±100 (1000±15)  100 (26)  2100±100 (305±15) 
4 2000 17400±100 (2500±50)  200 (53)  14 (4) 
5 2000 19300±350 (2800±50) 

Table 52
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
495-7571  CW  1000  131 (34) 
2 2000  262 (69) 
3 2000  6900±100 (1000±15)  131 (34)  2100±100 (305±15) 
4 2000  21600±350 (3100±100)  262 (69)  18 (5) 
5 2000  24000±350 (3500±100) 

Table 53
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
500-5264  CCW  1000  71 (18) 
2 2000 142 (37) 
3 2000 6900 (1000)  71 (18)  2200±350 (320±50) 
4 2000 18630 (2700)  142 (37)  10 (3) 
5 2000 20700±700 (3000±100) 

Table 54
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
501-8368  CW  1000  88 (23) 
2 2000 176 (46) 
3 2000 6900±100 (1000±15)  88 (23)  21200±100 (320±15) 
4 2000 18630 (2700)  176 (46)  13 (4) 
5 2000 20700±350 (4050±50) 

Table 55
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
506-0353  CCW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900 (1000)  110 (29)  2000±100 (290±15) 
4 2000 18630 (2700)  220 (58)  15 (4) 
5 2000 20700±700 (3000±100) 

Table 56
Test Specifications 
Part Number  Pump Rotation  Step  Input Speed  Discharge Pressure kPa (psi)  Discharge Flow lpm (gpm)  Max. Case Drain Flow lpm (gpm)  Margin Pressure kPa (psi) 
506-5611  CW  1000  110 (29) 
2 2000 220 (58) 
3 2000 6900±100 (1000±15)  110 (29)  2100±100 (305±15) 
4 2000 24840±300 (3650±50)  220 (58)  15 (4) 
5 2000 27600±350 (4050±50) 

Tooling

Table 57
Tooling 
Part Number  Adapter Plate  Drive Adapter  Suction Adapter  Split Flange  Flange Adapter  Pilot Pressure Port  Case Drain Port 
240-2647  1U-9128  1U-9834  1U-9873  1P-4577  9U-7444  7/16-20 STOR  7/8-14 STOR 
252-2680  1U-9128  1U-9834  1U-9873  1P-5767  9U-7440  7/16-20 STOR  7/8-14 STOR 
281-1623  1U-9128  1U-9834  1U-9873  1P-4577  9U-7444  7/16-20 STOR  7/8-14 STOR 
307-3044  Tandem pump made of 358-4992 (Front Pump, See This Document) and 358-4993 (Rear Pump, See This Document) 
325-9777  Tandem pump made of 325-9774 (Front Pump, See REHS1448) and 324-9778 (Rear Pump, REHS3451) 
325-9778  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 1/16-12 STOR 
325-9783  Tandem pump made of 325-9786 (Front Pump, REHS3451) and 324-9774 (Rear Pump, See REHS1448) 
325-9786  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 1/16-12 STOR 
338-2879  1U-9129  1U-9835  1U-9874  6V-0397  9U-7445  9/16-18 STOR  1 1/16-12 STOR 
341-7627  1U-9128  1U-9394  1U-9874  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
341-7660  Tandem pump made of 341-7627 (Front Pump, See This Document) and 358-4993 (Rear Pump, See This Document) 
341-7662  Tandem pump made of 341-7664 (Front Pump, See This Document) and 358-4993 (Rear Pump, See This Document) 
341-7664  1U-9128  1U-9394  1U-9874  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
342-2680  1U-9128  1U-9394  1U-9874  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
355-2397  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 1/16-12 STOR 
355-2407  Multiple pump made of 289-4027 (Rear, See REHS1375), 355-2397 (Front, REHS3451), and 355-2406 (Center, See REHS1448) 
358-4992  1U-9128  1U-9394  1U-9874  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
358-4993  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
365-2142  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
366-4955  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
367-8076  Tandem pump made of 367-8077 (front pump) and 307-8078 (rear pump). Refer to these part numbers in this instruction 
367-8077  1U-9128  1U-9834  1U-9874  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
367-8078  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
373-6527  1U-9128  1U-9394  1U-9874  6V-0397  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
373-6528  1U-9128  1U-9394  1U-9874  6V-0397  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
373-6629  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 1/16-20 STOR 
373-6630  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 1/16-20 STOR 
374-2567  1U-9128  1U-9394  1U-9874  6V-0397  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
374-2570  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
392-0187  1U-9128  1U-9834  1U-9873  1P-5767  9U-9440  7/16-20 STOR  1 1/16-12 STOR 
392-0230  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
397-9564  1U-9564  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 1/16-12 STOR 
416-8986  1U-9128  133-2329  1U-9874  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
418-2202  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
418-2205  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16–20 STOR  7/8–14 STOR 
424-1866  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16-20 STOR  7/8-14 STOR 
444-5235  1U-9128  1U-9835  1U-9874  6V-0397  9U-7445  9/16-18 STOR  1 1/16-12 STOR 
444-8538  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 5/16-12 STOR 
444-8539  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 5/16-12 STOR 
458-8651  1U-9128  1U-9394  9U-7159  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
458-8658  1U-9128  1U-9394  9U-7159  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
461-7098  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16–20 STOR  1 1/16–12 STOR 
464-4876  1U-9128  1U-9835  1U-9874  1P-5767  9U-7440  7/16-20 STOR  1 1/16-12 STOR 
464-4884  1U-9129  1U-9835  1U-9874  1P-5767  9U-7440  7/16–20 STOR  1 1/16–12 STOR 
464-4885  1U-9129  1U-9835  1U-9874  1P-5767  9U-7440  7/16–20 STOR  1 1/16–12 STOR 
468-3837  1U-9129  1U-9835  1U-9874  1P-5767  9U-7440  7/16–20 STOR  1 1/16–12 STOR 
475-0538  1U-9128  1U-9394  1U-9874  1P-5767  9U-7440  7/16–20 STOR  1 1/16–12 STOR 
476-6616  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16-20 STOR  1 1/16-12 STOR 
495-7571  1U-9129  1U-9835  1U-9874  6V-0397  9U-7445  7/16–20 STOR  1 1/16-12 STOR 
500-5264  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16–20 STOR  7/8–14 STOR 
501-8368  1U-9128  1U-9834  1U-9873  8C-3206  9U-7444  7/16–20 STOR  7/8-14 STOR 
506-0353  1U-9129  1U-9834  1U-9874  1P-5767  9U-7440  7/16–20 STOR  1 1/16-12 STOR 
506-5611  1U-9128  1U-9394  1U-9874  6V-0397  9U-7445  7/16–20 STOR  1 1/16-12 STOR 

Caterpillar Information System:

345D, 349D and 349D2 Excavator Machine System Specifications Check Valve
2015/06/12 New Track Roller Groups are Now Used on Certain Excavators {4180}
303.5E2 CR, 304.5E2 XTC, 304E2 CR, 305.5E2 CR and 305E2 CR Mini Hydraulic Excavators Machine System Specifications Stick Lines
Installation Procedure for the 486-8676 Control Ar - Auxiliary on Certain Hydraulic Excavators{1408, 1439, 5057, 5059, 5705, 7301, 7405, 7557} Installation Procedure for the 486-8676 Control Ar - Auxiliary on Certain Hydraulic Excavators{1408, 1439, 5057, 5059, 5705, 7301, 7405, 7557}
303.5E2 CR, 304E2 CR, 305E2 CR and 305.5E2 CR Mini Hydraulic Excavators Declaration of Conformity
323D2, 326D2 and 330D2 Excavators and 330D2 MHPU Machine Electronic Control System Connector Contact Description
307E2 Mini Hydraulic Excavator Fuses - Replace
349F and 352F Excavators Machine System Specifications Grease Lines
307E2 Mini Hydraulic Excavator Mirror Installation
307E2 Mini Hydraulic Excavator Fuel Lift Pump Strainer - Replace
307E2 Mini Hydraulic Excavator Capacities (Refill)
349F and 352F Excavators Machine System Specifications Travel Motor
Installation Procedure for the 465-1060 Front Lines Gp on Certain Hydraulic Excavators{5057} Installation Procedure for the 465-1060 Front Lines Gp on Certain Hydraulic Excavators{5057}
307E2 Mini Hydraulic Excavator Operator Controls
Machine Security System (MSS3i) Integrated General Information
Machine Security System (MSS3i) Integrated System Overview
329F and 330F Excavators Maintenance Interval Schedule
Machine Security System (MSS3i) Integrated Operation of Status Indicator
Machine Security System (MSS3i) Integrated Key Information
Machine Security System (MSS3i) Integrated Scheduled Access - "Security System Bypass Times"
Machine Security System (MSS3i) Integrated Diagnostic Operation
303.5E2 CR, 304E2 CR, 305E2 CR and 305.5E2 CR Mini Hydraulic Excavators Machine Systems Electronic Control (Machine System)
Machine Security System (MSS3i) Integrated Protected Functions
Machine Security System (MSS3i) Integrated Service Operation Using Service Tool
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.