Perform all implement system calibrations including lever, sensor, and linkage calibrations.
Warm up machine including hydraulic system and linkage & pin grease.
Best Practices For Selecting Calibration Material and Weighing On External (Site) Scales
- Run Full Calibration with on-site material.
Use suggested calibration weight.
- Perform bucket zero.
- Perform simple calibration with four or five trucks to fine-tune calibration.
Reference: "Option One Example"
- Run Full Calibration with on-site material.
Weigh loader empty and loaded using site scales.
- Enter measured bucket payload as the calibration weight.
- Perform bucket zero.
- Perform simple calibration with four or five trucks to fine-tune calibration.
If no site scales available:
- Perform full calibration with known calibration weight and use known weight as calibration weight.
Note: Option three could be less accurate due to differences in how a known weight and on-site material will fill the bucket.
- Run full calibration.
- Touch "Service" > "Service Mode".
- Enter password to enable service mode in the display.
- Touch "Service" > "Calibrations" > "Payload".
- Perform Empty Bucket Weight calibration with a clean, empty bucket.
- Perform Full Bucket Weight calibration with on-site material.
Show/hide tableIllustration 1 g06004728 Calibration weight entry screen - Enter suggested calibration weight as a calibration weight.
- Touch "Home" > "Payload".
You will be prompted to enter the calibration weight.
- Enter the suggested weight listed under "Current Cal Weight" into the number pad.
- Press "OK".
- Touch "Home" > "Payload".
- Perform bucket zero and simple calibration on four or five trucks.
- Weigh an empty truck (tare weight) with on-site scales.
- Perform Bucket Zero.
- Fully load the truck with on-site material with the payload system active.
- Press the store button when truck is fully loaded.
- Weigh the loaded truck with on-site scales and record scale weight.
- Repeat Steps 3.a through 3.e four more times.
Note: Simple calibration can be performed using 1 to 15 trucks. The more trucks used, the better the calibration will be fine-tuned. The recommended number of trucks for most applications is 5.
- Touch "Service" > "Calibrations" > "Payload".
- Select Simple Calibration.
- Select each truck from the list and correct the Cat Production Measurement weigh with the scale weight.
Note: A new simple calibration erases all prior simple calibrations. Only the latest simple calibration on one or more trucks is used to fine-tune the scale system.