Usage:
Typical Illustration
NOTE: Two shutoffs are used in dual turbocharger applications.
(1) Valve assembly shown in the open position.
When the valve is closed a 0.08 mm (.003 in.) feeler gauge must not fit between the valve and the bore in the pipe at any point.
(2) 3N4586 Torsion Spring:
Free length ... 47.5 ± 0.5 mm (1.87 ± .02 in.)
Outside diameter ... 30.7 ± 0.5 mm (1.21 ± .02 in.)
(2) 5N2761 Torsion Spring:
Free length ... 49.8 ± 0.5 mm (1.96 ± .02 in.)
Outside diameter ... 30.7 ± 0.5 mm (1.21 ± .02 in.)
(3) 3N7848 Spring:
Free length ... 35.6 ± 0.5 mm (1.40 ± .02 in.)
Outside diameter ... 18.8 ± 0.5 mm (.74 ± .02 in.)
(4) 3N7562 12V Solenoid
3N7563 24 or 32V Solenoid
4N3889 12V Solenoid
4N3890 24 or 32V Solenoid
Plunger travel* ... 11.7 ± 0.3 mm (.46 ± .01 in.)
*Hold-in current consumption (draw) on engine must be less than 2A.