Usage:
7C5417 Switch
Switch operates when the temperature increases to ... 97 to 99°C (208 to 210°F)
7W0872 Switch
Switch operates when the temperature increases to ... 101 to 103°C (214 to 217°F)
5N8857 Switch
Terminal A is normally open below actuation temperature.
Terminal B is common.
Terminal C is normally closed below actuation temperature.
With a temperature increase to 97 to 99°C (208 to 210°F), terminal A closes and terminal C opens.
With a temperature decrease to 91°C (196°F), terminal A opens and terminal C closes.
(1) Final torque for switch assembly ... 52 ± 8 N·m (38 ± 6 lb ft)
9Y0914 Switch
Terminal A is normally open below actuation temperature.
Terminal B is common.
Terminal C is normally closed below actuation temperature.
With a temperature increase to 100 to 103°C (213 to 217°F), terminal A closes and terminal C opens.
With a temperature decrease to 95°C (203°F), terminal A opens and terminal C closes.
(1) Final torque for switch assembly ... 52 ± 8 N·m (38 ± 6 lb ft)