Programmable Parameters

Many programmable parameters affect engine operation. Certain parameters affecting Industrial Engine operation may be changed with an Electronic Service Tool. Some parameters may affect engine operation in ways an operator does not expect. Without adequate training, these parameters may lead to power or performance complaints, even when the engine is performing to specification.

The parameters are stored in the ECM, and are protected from unauthorized changes by passwords. These parameters are either System Configuration Parameters or Customer Specified Parameters. Any parameter can be read, however, passwords protect parameters from unauthorized changes.

Two categories contain various parameters, System Configuration Parameters and Customer Specified Parameters. System Configuration Parameters can be altered only with the proper factory passwords using an Electronic Control Analyzer & Programmer (ECAP) or Caterpillar Electronic Technician (ET). Customer Specified Parameters can be changed using an Electronic Service Tool only with the proper customer passwords.

Refer to the topics, Passwords, System Configuration Parameters and Customer Specified Parameters for more details on how to receive and use Factory Passwords and Customer Passwords.

NOTE: For details on how to read and change parameters using an ECAP, refer to Special Instruction SEHS8886 (if using the NEXG4522 Industrial Engine Functions Service Program Module set).

System Configuration Parameters are set at the factory and affect emissions or power ratings within a family of engines. Factory passwords must be obtained and used to change System Configuration Parameters.

Customer Specified Parameters are variable and can be used to affect engine rpm limits, rpm/power ratings within the limits set by the factory and Caterpillar Engine Monitoring. Customer passwords are necessary to change Customer Specified Parameters.

System Configuration Parameters

System Configuration Parameters affect emissions or power of the engine. They are programmed at the factory and would normally never need to be changed through the life of the engine. System Configuration Parameters must be reprogrammed if an ECM is replaced but not if the Personality Module is replaced (unless the engine rating changes). Proper values for these parameters are stamped on the Engine Information Plate located on the valve cover or inlet manifold. The following is a description of the System Configuration Parameters.

Full Load Setting

The setting number represents the fuel system adjustment performed at the factory to fine tune the fuel system. A new ECM must have this parameter programmed to avoid generating a Diagnostic Code 253-02 Check Customer Or System Parameters (56).

Full Torque Setting

Similar to Full Load Setting, this parameter must be programmed or a Diagnostic Code 253-02 Check Customer Or System Parameters (56) will be generated.

Personality Module Code

Code which prevents use of incorrect Personality Module for this engine. Each power family has a different code associated with it. When a Personality Module is replaced (either using a Personality Module chip or if flash programmed), this code (stored in the ECM) must match the one in the introduced Personality Module or the engine will only run at low idle and a Diagnostic Code 253-02 Check Customer Or System Parameters (56) will also be generated. When rerating the engine, programming this code to "0" will prompt the ECM to read and match its stored code to the Personality Module Code.

Engine Serial Number

The engine serial number should be programmed to match the engine serial number stamped on the Engine Information Plate. A new ECM is delivered with the engine serial number programmed to 0XX00000.

Customer Specified Parameters

Customer Specified Parameters allow the engine owner to influence how a unit operates. Some parameters may affect engine operation in ways an inadequately trained operator does not expect. These parameters may lead to power or performance complaints, even when the engine is performing to specification.

Customer parameters may be changed repeatedly as a customer changes his operation or as new operators are assigned. Customer passwords are required to changed these parameters.

The following is a brief description of the Customer Specified Parameters with the minimum and maximum values for the parameter and the default value. The tables show values in metric units followed by an approximate range for its US (or English) units counterpart. The exact range of the parameter in metric units depends upon the Electronic Service Tool used because each tool may use slightly different conversion factors.

Engine Power Rating Selection Number

Number of rating within power family. The Personality Module defines the power family [such as 242 kW (325 hp)] and may contain only one or several ratings. The rating number defines which rating is used [such as 242 kW (325 hp) and 1900 rpm or 242 kW (325 hp) and 2100 rpm] within the family.

Vehicle ID

Identification of the machine assigned by the customer. Used only for customer reference, not required by the ECM.

Tachometer Calibration

Used by the ECM to scale the engine speed signal into revolutions per minute for a tachometer. Programmed in pulses per revolution, the range is from 12 to 500 ppr.

Low Idle

Minimum programmable engine rpm that the engine will run with the throttle or throttle switch at minimum position.

Auxiliary Temperature

High Auxiliary temperature can be programmed to any value from 50 to 120°C (122 to 248°F). The High Auxiliary Temperature Lamp on the CMS will flash when the auxiliary temperature exceeds the high set point.

PTO/Extend Idle Engine RPM Limit (PTO Mode engine RPM Limit)

Minimum programmable engine PTO rpm limit.

PTO Engine RPM Rate

Engine rpm rate of increase/decrease. This parameter determines Accel, Decel, and Resume PTO Engine rpm rates of increase/decrease. The parameter can be set to an rpm value between 5 and 1000 inclusively.

Top Engine Limit (TEL)

Maximum engine rpm when the engine is under load. the engine will still achieve Rated RPM under no load conditions.

NOTE: TEL is dependent upon the RATING number with some RATING numbers allowing no or little variation.

Top Engine Limit with Droop (Top Engine Limit Overrun)

Allows the engine to exceed the Top Engine Limit with a partial load. The "RPM Limit" increases linearly as load decreases to 150 rpm above the selected limit for no load.

A/C Pressure Switch Fan-On Time

An input to the ECM is available for connection of a normally closed High Pressure A/C Switch. The ECM has a timer built in to prevent excessive cycling of the cooling fan clutch due to successive cycling of the A/C switch input.

Engine Monitoring Mode

Determines the level of action taken by the ECM in response to a potentially engine damaging condition. The ECM will respond to inputs from the Coolant Temperature, Inlet Manifold Temperature, Oil Pressure, Or Coolant Level (if installed) Sensors. Refer to Troubleshooting With A Diagnostic Code for information regarding diagnostic codes and their effect on engine operation.

Coolant Level Sensor Enable/Disable

Determines if the ECM monitors the Coolant Level Sensor Inputs.

Fuel Correction Factor

The fuel correction factor is available to fine tune all fuel data stored in the future by the ECM. Caterpillar recommends this factor be changed only after a significant operating interval with a comparison o factual tank capacity fuel economy compared to ECM recorded fuel economy. The operating interval should also reflect a typical operating routing. The Factor is a percentage, programmable in one-half (0.5) percent increments.

Calculating Fuel Correction Factor

The following formula should be used to determine the Fuel Correction Factor (FCF).

New FCF = Old FCF + [(100 + old FCF) X error] ÷ 100 where old FCF is the Fuel Correction Factor currently in the ECM, and error is calculated as follows: error = [(tank economy - ECM economy) ÷ tank economy] × 100.

Example

Tanks capacity fuel economy is 7.1 mpg, ECM economy is 7.0 mpg with an old FCF of -2.5. Therefore error is [7.1 - 7.0) ÷ 7.0] × 100 = 1.4. The new FCF is -2.5 + [(100 + {-2.5}) × 1.4) ÷ 100 = -1.135 rounded off to the nearest 0.5, new FCF = -1.0.

Maintenance Indicator Mode

The ECM records data related to unit maintenance. When selected (Manual - Hours or Automatic - Hours), then all maintenance indications (PM Level 1, PM Level 2, Coolant Flush/Fill) on the service tool will be in hours. The ECM provides PM Level 1 maintenance interval and last maintenance information.

PM1 Interval

PM1 Interval allows a user-specified PM1 maintenance interval. This parameter (PM1 Interval) must be programmed only if Maintenance Indicator Mode is programmed to Manual - Hours.

PM Level 1 Engine Oil Capacity In Quarts (For Automatic Maintenance Indicator Mode

PM1 Interval can be determined from the ECM based on fuel usage. This parameter must be programmed only if Maintenance Indicator Mode is programmed to Automatic - Hours

Passwords

Factory Passwords

Factory passwords are required to perform each of the following four functions.

1. Program a new ECM.

- When an ECM is replaced, the System Configuration Parameters must be programmed into the new ECM. For a new ECM these parameters can be programmed once without factory passwords, thereafter these parameters are protected by factory passwords.

2. Rerate engine to another power rating.

- This requires changing the Personality Module Code, which is protected by factory passwords. Includes changing from a non torque to a multi torque.

3. Read customer passwords.

- If the owner loses the customer passwords, the customer will not be able to program Customer Specified Parameters. Using factory passwords, one can read customer passwords, then use those customer passwords to program Customer Specified Parameters.

4. Clear certain diagnostic codes.

- Diagnostic Code 190-00 (Engine Overspeed Warning) requires factory passwords to clear once it is logged. Diagnostic Code 252-11 Incorrect Engine Software (Flash Code 59) also requires factory passwords. It should be cleared only if you are certain the Personality Module is for the specific engine.


NOTICE

Installing an ECM with a 3176B Industrial Engine Personality Module on another engine (or the reverse) will damage the engine. Be sure the Personality Module is correct for your engine.


Certain other diagnostic codes require customer passwords. The majority of logged codes require no passwords to clear. Since factory passwords contain alphabetic characters, only the ECAP or ET may perform these functions.

To obtain factory passwords, proceed as if you already had the password. At some point, if factory passwords are truly needed, the ECAP or ET will request factory passwords and display most of the information required to obtain the passwords.

Customer Passwords

If customer passwords have been entered, they are then required to change ANY Customer Specified Parameter. Customer Specified Parameters are those that affect engine rpm limits, power rating and PTO operation within a family. Refer to the Customer Specified Parameters for more detail on what parameters are customer programmable.

The ECAP or ET Electronic Service Tools may change Customer Specified Parameters. To obtain customer passwords, contact the owner of the unit. If the owner has lost the passwords, customer passwords may be read using an Electronic Service Tool (factory passwords are required in order to read the customer passwords). Follow the procedure below.

1. Use the Electronic Service Tool to access Read/Change System Configuration Parameters, then read customer parameters.

2. When the Factory Passwords screen appears, record the information listed on the Factory Passwords Worksheet.

3. Obtain the factory passwords. The information recorded above must be provided, and generates a permanent record at Caterpillar of the access.

4. Enter the factory passwords from the Factory Passwords screen.

5. When the Read Customer Passwords screen appears, record the customer passwords. The customer passwords may then be used to change Customer Specified Parameters.

System Configuration Parameters are protected by factory passwords. Factory passwords are calculated on a computer system available only to Caterpillar dealers. Since factory passwords contain alphabetic characters, only an ECAP or ET Electronic Service Tool may change System Configuration Parameters. System Configuration Parameters affect power family or emissions.

Customer Specified Parameters are protected by customer passwords. The customer passwords are programmed by the customer. Refer to Programmable Parameters, for more details when passwords are needed and how to obtain them.

ECM Replacement Procedure

The Electronic Control Module (ECM) is the heart of the Electronic Control System used on the 3176B Industrial Engine. The ECM contains no moving parts, has a very high reliability rating and replacement can be time consuming. Most problems occur in the connectors, wiring, or sensors. Follow the troubleshooting procedures outlined in this guide. DO NOT replace an ECM on speculation!

To ensure the suspect ECM is the cause of the problem, temporarily connect a new or test (known good) ECM, before replacing the old ECM. To temporarily connect a test ECM you must transfer the Personality Model data from the old ECM to the test ECM and program any necessary parameters required for testing (the parameters must be programmed exactly as they were in the old ECM). Refer to the following test steps for details. If the test ECM resolves the problem, reconnect the old ECM and verify the problem returns. If the problem returns, replace the old ECM.

The parameters stored in the ECM to be replaced, must be read with an Electronic Service Tool and recorded. The Personality Module from the old ECM must be FLASH downloaded to the new ECM. After the new ECM is installed on the engine, the parameters recorded from the old ECM must be programmed into the new ECM and the injection timing must be recalibrated.

NOTE: If the parameters cannot be read they must be obtained elsewhere. Some parameters are stamped on the Engine Information Plate, but most parameters must be obtained from the user or dealer that installed the engine.

The following procedure is a summary of the basic steps necessary to program a replacement ECM.

1: Use a copy of the Read/Change Parameters Worksheet in this manual to record the Parameters from the ECM being replaced.

NOTE: It is recommended to record any Logged Events also.

(a) Use the Communication Adapter Tool and connect ET to access Parameters from the ECM being replaced.

(b) Record the Parameters listed on the worksheet.

2: Replace the faulty ECM.

(a) Turn the keyswitch to the OFF position.

(b) Use a 4 mm Allen wrench to disconnect both 40-Pin Deutsch connectors.

(c) Remove the fuel lines, ECM mounting bolts and disconnect the ECM ground strap.

------ WARNING! ------

Use caution when removing fuel lines. The fuel may be under pressure and can penetrate body tissue.

--------WARNING!------

d) DO NOT lose any of the ECM mounting hardware (i.e. rubber grommets, spacers and washers).

e) Ensure the old ECM's mounting hardware is free of damage and use it to install the new ECM. Reconnect the fuel lines. Ensure the ECM mounting hardware is installed correctly. Verify the fuel lines are not tugging or pulling on the ECM. The rubber grommets are used to protect the ECM from excessive vibration. When installed correctly, the ECM can drift in the rubber grommets. If the ECM cannot be moved slightly in the grommets, check that the fuel lines are not pulling the ECM against one side of the grommets.

(f) Reconnect the 40-Pin Deutsch connectors and the ground strap to the ECM.

3: Always use FLASH downloading whenever possible. Use ET to FLASH download the Personality Module information into the ECM (refer to the instructions included with JERD2124 ET Software and the JERD2129 ET Data Subscription for more information).

(a) Connect ET through the Communication Adapter Tool.

(b) Turn the keyswitch to the ON position.

(C) Select the FLASH Download option from the ET menu.

(d) Select the appropriate file to be downloaded from a disk on the laptop PC. Use an Electronic Service Tool to program the Read/Change Parameters

(e) Enter all the parameters recorded in Step 1, Full Load Setting, Engine Serial Number, etc.

(f) Due to the ECAP's limited abilities you may not be able to program all the needed parameters.

4: Calibrate the Injection Timing. Use the Electronic Service Tool to select Monitor/Calibrate Timing option to calibrate the Timing Refer To P-614: Engine Speed/Timing Sensor Calibration.

Programming a Personality Module Using Flash Programming

NOTE: Operation of the engine following programming of the Personality Module is identical to operation following replacement of the Personality Module chip. The only difference is the software was already programmed in the chip for you when you replaced the chip, now you are actually performing the programming function.

For example, if you are rerating an engine, you will still need factory passwords to change the Personality Module Code.

1. Connect hardware as shown.

2. Start the LEXT3037 PC Program, or Flash from the Electronic Technician (ET) Service Tool.

3. Select the engine Personality Module part number to be programmed into the ECM, and proceed with programming the Personality Module. The new ECM is shipped with a blank Personality Module.

4. PC Program Personality Module Messages and their meanings are discussed in the following procedure.

NOTE: A new ECM has a blank (previously unprogrammed) Personality Module. A blank Personality Module will prompt you for all three of the following messages.

The information contained in the "ECM Status" will be scrambled and meaningless if the module has not been previously programmed (this is normal).

- Message - "The engine ID in the flash file does not match the engine ID in the ECM."
- Meaning - The ECM has a Personality Module installed for a different engine. For example, the ECM has a 3176B Industrial Personality Module and you are attempting to program another Personality Module into it.
- What you should do - Stop the transfer and access information about "ECM Status" under the "Electronic Control Module" menu. Ensure the file you are about to transfer is for the same engine it will be installed in.
- Message - "The application ID in the flash file does not match the application ID in the ECM."
- Meaning - The ECM has a Personality Module installed for a different application.
- What you should do - Stop the transfer and access information about ECM Status under the Electronic Control Module menu. Make sure the file you are about to transfer is for the Industrial application.
- Message - "The ECM ID in the flash file does not match the ECM ID in the ECM."
- Meaning - The ECM is not for use in the 3176B Industrial application.
- What you should do - Stop the transfer and access information about ECM Status in the Electronic Control Module menu. Ensure the ECM on the engine is for a 3176B Industrial application.

NOTE: If you access the ECM Status under the Electronic Control Module menu of the PC Program, but do not follow (or have not followed) this procedure by programming the Personality Module, you must turn the keyswitch to the OFF position, and then to the ON position before using an Electronic Service Tool. If you do not cycle the keyswitch after reading the ECM Status, the ECM will not communicate with your service tool or start the engine. Cycling the keyswitch is not necessary following successful programming of a Personality Module using the Flash Designer Program.

5. Start the engine and check for proper operation.

- Program any parameters not previously in the old Personality Module if 253-02 Check Customer Or System Parameters (56) code is active. Read the code from the Active diagnostic code screen of the Electronic Service Tool to determine the parameter(s) requiring programming.
- Remember, on initial powerup of a new ECM, five parameters must be programmed to avoid a 253-02 Check Customer Or System Parameters (56) code. They are Full Load Setting (FLS), Full Torque Setting (FTS), Rating Number and Engine Serial Number and Output Shaft Speed Calibration (ppm).

Factory Passwords Worksheet

Customer Parameter Worksheet

Caterpillar Information System:

3176B INDUSTRIAL ENGINE Section 1: Electronic System Overview
3176B INDUSTRIAL ENGINE Introduction
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Section 6: Glossary Of Terms
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Section 5: Functional Tests
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Section 4: Troubleshooting With A Diagnostic Code
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Section 3: Troubleshooting Without A Diagnostic Code
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Section 2: Programming Parameters
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Section 1: Electronic System Overview
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Introduction
DISSASSEMBLY & ASSEMBLY 3512 INDUSTRIAL ENGINE Crankshaft
DISSASSEMBLY & ASSEMBLY 3512 INDUSTRIAL ENGINE Camshaft Bearings
DISSASSEMBLY & ASSEMBLY 3512 INDUSTRIAL ENGINE Camshafts
3176B INDUSTRIAL ENGINE SECTION 3: Troubleshooting Without A Diagnostic Code
3176B INDUSTRIAL ENGINE Section 4: Troubleshooting With A Diagnostic Code
3176B INDUSTRIAL ENGINE Section 7: Glossary of Terms
3176B Industrial Engine 3176B Industrial Engine
3512 INDUSTRIAL ENGINE OIL WELL SERVICE Schematic
3176B MARINE ENGINE The Diagnostic Process
3176B MARINE ENGINE Diagnostic Codes Cross-Referenced By PID-FMI
3176B MARINE ENGINE 1.0 3176B Electronic System Overview
3176B MARINE ENGINE 2.0 Programming Parameters
3176B MARINE ENGINE 3.0 Troubleshooting Using Symptoms
3176B MARINE ENGINE 3.1 Possible Performance Affect of ACTIVE Diagnostic Codes
3176B MARINE ENGINE 4.0 Troubleshooting With A Diagnostic Code
Back to top
The names Caterpillar, John Deere, JD, JCB, Hyundai or any other original equipment manufacturers are registered trademarks of the respective original equipment manufacturers. All names, descriptions, numbers and symbols are used for reference purposes only.
CH-Part.com is in no way associated with any of the manufacturers we have listed. All manufacturer's names and descriptions are for reference only.