3304B & 3306B MARINE ENGINES Caterpillar


Shutoff Solenoids

Usage:

Energize To Run (ETR)

(1) Distance from the plunger face to the flange face ... 11.3 mm (.44 in)

8C6099 (24/32V)

Current consumption (draw) at 38.4V ... 15.4A max

Coil resistance at 25°C (77°F) ... 3.33 to 4.07 Ohms

(1) Distance from the plunger face to the flange face (min) ... 65.3 mm (2.57 in)

8C9986 (12V)

Current consumption (draw):

Pull in windings at 14.4V ... 78.6A

Hold in windings at 14.4V ... 1.8A

Coil resistance:

Pull in windings at 25°C (77°F) ... 0.28 ± 0.03Ohms

Hold in windings at 25°C (77°F) ... 12 ± 1.2Ohms

8C4771 (24V)

Current consumption (draw):

Pull in windings at 28.8V ... 41.9A

Hold in windings at 28.8V ... 0.89A

Coil resistance:

Pull in windings at 25°C (77°F) ... 1.02 ± 0.10Ohms

Hold in windings at 25°C (77°F) ... 48 ± 4.8Ohms

Energize To Shutoff (ETS)

(1) Distance from the plunger face to the flange face (max) ... 57.06 mm (2.25 in)

110-6464 (12V)

Current consumption (draw) at 14.4V ... 15.3A max

Coil resistance at 25°C (77°F) ... 1.33 ± 0.07Ohms

110-6465 (24V)

Current consumption (draw) at 28.8V ... 7.9A max

Coil resistance at 25°C (77°F) ... 5.12 ± 0.26Ohms