Usage:
(1) Distance from the plunger face to the flange face ... 11.3 mm (.44 in)
8C6099 (24/32V)
Current consumption (draw) at 38.4V ... 15.4A max
Coil resistance at 25°C (77°F) ... 3.33 to 4.07 Ohms
(1) Distance from the plunger face to the flange face (min) ... 65.3 mm (2.57 in)
8C9986 (12V)
Current consumption (draw):
Pull in windings at 14.4V ... 78.6A
Hold in windings at 14.4V ... 1.8A
Coil resistance:
Pull in windings at 25°C (77°F) ... 0.28 ± 0.03Ohms
Hold in windings at 25°C (77°F) ... 12 ± 1.2Ohms
8C4771 (24V)
Current consumption (draw):
Pull in windings at 28.8V ... 41.9A
Hold in windings at 28.8V ... 0.89A
Coil resistance:
Pull in windings at 25°C (77°F) ... 1.02 ± 0.10Ohms
Hold in windings at 25°C (77°F) ... 48 ± 4.8Ohms
Energize To Shutoff (ETS)
(1) Distance from the plunger face to the flange face (max) ... 57.06 mm (2.25 in)
110-6464 (12V)
Current consumption (draw) at 14.4V ... 15.3A max
Coil resistance at 25°C (77°F) ... 1.33 ± 0.07Ohms
110-6465 (24V)
Current consumption (draw) at 28.8V ... 7.9A max
Coil resistance at 25°C (77°F) ... 5.12 ± 0.26Ohms